Download Print this page
KERN Optics ORA 4 FA Operating Manual

KERN Optics ORA 4 FA Operating Manual

Analogue refractometer, analogue antifreeze vw standard

Advertisement

Quick Links

Operating manual
Analogue refractometer
KERN ORA 4 FA/FB Analogue Antifreeze
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
CONTENTS
1
Technical data.................................................................................................1
2
Description......................................................................................................2
3
General information .......................................................................................3
3.1 Intended use ...................................................................................................3
3.2 Warranty..........................................................................................................3
4
Basic safety information ...............................................................................4
4.1 Follow the instructions in the operating manual .......................................4
4.2 Warning ....................................................................................................... 4-5
5
Supplied items ................................................................................................5
6
Before the first use ........................................................................................6
7
Use/measurement.........................................................................................6
7.1 Zero point calibration ................................................................................ 7-8
7.2 Additional advice ............................................................................................9
7.3 Measuring procedure for antifreeze testing ......................................... 9-10
7.4 Measuring procedure for windscreen wiper water testing .................... 10
7.5 Measuring procedure for determining battery acid density .................. 11
8
Cleaning and maintenance ......................................................................... 12
9
Storage ......................................................................................................... 13
10 Service.......................................................................................................... 13
11 Disposal ........................................................................................................ 13
12 Additional information ................................................................................ 13
1. Technical data
1 Technische Daten
Modell
Measuring range
KERN
and Scales
Mo d e lle
K E R N
O R A 4 F B
EG: -50°C – 0°C G13
PG: -50°C – 0°C
ORA 4 FA/FB
G11/12
CW: -40°C – 0°C
BF: 1,10 – 1,40 kg/l
B
Example scale on
ORA 4 FB
2 Gerätebeschreibung
3
2
2. Description
Gerätebeschreibung
1
3
3
2
1. Prismenabdeckung
2. Prismenfläche
3. Justierschraube
1
4. Okular mit Gummi-Augenmuschel
5. Einstellring des Diopters
6. Optische Röhre mit Gummigriff
1. Prismenabdeckung
2. Prismenfläche
3. Justierschraube
8
4. Okular mit Gummi-Augenmuschel
5. Einstellring des Diopters
6. Optische Röhre mit Gummigriff
7
8
7. Aufbewahrungsbox
8. Pipette
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Betriebsanleitung
Analoges Refraktometer
KERN
ORA 4 FB Analog Antifrost
VW Standard
Manual_ORA-U_V1
Version 1.0
12/2014
VW Standard
Tel: +49- [ 0 ] 7433-9933-0
Fax: +49- [ 0 ] 7433-9933-149
Internet: www.kern-sohn.com
ORA_4FB-BA-d-1410
Scale
Dimensions
graduations
Product
Abmessungen
Nettogewicht
Mes s bereic h
S kalen-­‐
Produkt
und
t eilung
Accuracy
S kalen
Genauig keit
160x40x40mm
0,140kg
EG:   -­‐5 0 °C –
1 °C
0 °C G1 3
1 °C
1°C
PG:   -­‐5 0 °C –
5 °C
0 °C G1 1 / 1 2
0 ,0 1   kg / l
C W:   -­‐4 0 °C –
1°C
0 °C
160x40x40mm
BF: 1 ,1 0 –
1 ,4 0   kg / l
5°C
0,01 kg/l
4
5
1. Prism cover
4
ORA_4FB-BA-d-1410
2. Prism surface
6
3. Adjustment screw
4. Eyepiece with rubber eyeshade
5. Diopter adjustment ring
5
6. Optical tubes with rubber grip
6
7. Storage box
9
8. Pipette
9. Refractometer
10. Calibration liquid
10
(Distilled water)
11
11. Adjustment tool
9
12. Cleaning cloth
12
10
3. General information
GB
3.1 Intended use
Tel: +49-[0]7433- 9933-0
The refractometer is a measuring instrument for determining the refractive index of
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
transparent substances in the liquid or the solid state. It is used to observe the
behaviour of light as it passes from a prism with known properties to the substance
being tested.
Use of the refractometer for other purposes is contrary to its intended use and may
be hazardous. The manufacturer shall not be liable for any damages caused
by improper use.
3.2 Warranty
The warranty shall be void in the event of:
ORA-BA-d-1410
4. Basic safety information
4.1 Follow the instructions in the operating manual
4.2 Warning
▸ Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
▸ If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immediately.
▸ Thoroughly clean the refractometer after each use.
▸ The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
▸ This refractometer is not a toy. Keep out of reach of children.
▸ Make sure that you will not be hit by anything else while you are using the
refractometer, as this could cause serious eye injuries
Net weight
▸ The rubber eyeshade may cause irritation when in prolonged contact with the
skin. If this happens, consult your doctor.
▸ Do not touch the lenses with your fingers.
0,140kg
5. supplied items
After unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
1
6. Before the first use
Remove the protective film ( if present ) from the prism surface [ 2 ] and check that
the rubber eye-cup [ 4 ] is fitted correctly.
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. To ensure correct measure-
ment, the measuring device should be adjusted before measurements are carried
out. Please make sure your hands are dry before handling the measuring device.
2
▸ Failure to observe the instructions in the operating manual
▸ Use for purposes other than those described
▸ Modifications or opening the device housing
▸ Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
▸ Every language version includes a non-authoritative translation.
The original German document is the definitive version.
▸ Refractometer
▸ Storage box
▸ Pipette
▸ Adjustment tool
▸ Cleaning cloth
▸ Calibration liquid (Distilled water)
3
4
5
6

Advertisement

loading
Need help?

Need help?

Do you have a question about the ORA 4 FA and is the answer not in the manual?

Questions and answers

Summary of Contents for KERN Optics ORA 4 FA

  • Page 1 Use of the refractometer for other purposes is contrary to its intended use and may Manual_ORA-U_V1 be hazardous. The manufacturer shall not be liable for any damages caused by improper use. KERN ORA 4 FA/FB Analogue Antifreeze Version 1.0 12/2014 VW Standard 3.2 Warranty...
  • Page 2 7.1 Zero point calibration 7.5 Measuring procedure for determining battery acid density ▸ Hold up the refractometer against a sufficiently bright light source and look through ▸ Instead of antifreeze solution, place some battery acid on the prism surface [ 2 ] the eyepiece [ 5 ] , holding the rubber eyeshade [ 4 ] closely against your eye/glasses.

This manual is also suitable for: