Operating manual
Analogue refractometer
KERN
ORA 80 BE Analogue Expert
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Contents
1
Technical data .................................................................................................1
2
Description .....................................................................................................2
3
General information .......................................................................................3
3.1 Intended use ...................................................................................................3
3.2 Warranty .........................................................................................................3
4
Basic safety information ................................................................................4
4.1 Follow the instructions in the operating manual ..........................................4
4.2 Warning .......................................................................................................4-5
5
Supplied items ................................................................................................5
6
Before the first use .........................................................................................6
7
Use/measurement .........................................................................................6
7.1 Zero point calibration ................................................................................. 7-8
7.2 Additional advice ............................................................................................9
7.3 Measuring procedure ............................................................................... 9-10
8
Cleaning and maintenance .......................................................................... 11
9
Storage ......................................................................................................... 11
10 Service ......................................................................................................... 11
11 Disposal ....................................................................................................... 12
12 Additional information................................................................................. 12
13 Brix to refractive index ( nD ) conversion table ............................................ 13
14 Annex ........................................................................................................... 14
1. technische Daten
Measuring
Models
1 Technische Daten
range and
KeRn
Scales
Mo d e lle
Mes s bereic h
K E R N
Brix: 0-50%
O R A
Brix: 0 -‐5 0 %
oRA 80Be
8 0 B E
Brix: 50-80%
Beispiel der Skala für den ORA 80 BE
Example scale on
ORA 80 BE
Gerätebeschreibung
6
3
6
2
2. Description
2 Gerätebeschreibung
1
6
3
3
6
1. Prismenabdeckung
2
2. Prismenfläche
3. Optische Röhre mit Griff
4. Okular mit Einstellring des Diopters
5. Messbereich Verstellrad
6.
Einstellschraube
1
1. Prismenabdeckung
2. Prismenfläche
8
3. Optische Röhre mit Griff
4. Okular mit Einstellring des Diopters
5. Messbereich Verstellrad
6.
Einstellschraube
7
8
7. Aufbewahrungsbox
8. Pipette
Betriebsanleitung
Analoges Refraktometer
KERN
ORA 80 BE Analog Expert
2-fach Skala Brix
Version 1.0
12/2014
2x Brix scale
Tel: +49- [ 0 ] 7433-9933-0
Fax: +49- [ 0 ] 7433-9933-149
Internet: www.kern-sohn.com
ORA_80BE-BA-d-1410
Scale
Dimensions
graduations
Product
Accuracy
Abmessungen
Nettogewicht
S kalen-‐
Produkt
und
t eilung
S kalen
Genauig keit
0,5 % Brix
0 ,5 % Brix
180x40x40mm
0,400kg
180x40x40mm
Brix: 5 0 -‐
0 ,5 % Brix
0,5 % Brix
8 0 %
4
5
1. Prism cover
2. Prism surface
4
ORA_80BE-BA-d-1410
3. Optical tubes with grip
4. Eyepiece with diopter adjustment ring
5. Adjusting wheel measuring range
6. Adjusting screw
5
9
7. Storage box
8. Pipette
9. Refractometer
10
10. Calibration liquid
11
(Distilled water)
11. Adjustment tool
9
12. Cleaning cloth
12
3. General information
GB
3.1 Intended use
KERN & Sohn GmbH
Ziegelei 1
Tel: +49-[0]7433- 9933-0
D-72336 Balingen
Fax: +49-[0]7433-9933-
E-Mail: info@kern-
149
sohn.com
Internet: www.kern-
The refractometer is a measuring instrument for determining the refractive index of
sohn.com
transparent substances in liquid or in some cases also in the solid state. It is used
to observe the behaviour of light as it passes from a prism with known properties
to the substance being tested.
Use of the refractometer for other purposes is contrary to its intended use and
may be hazardous. The manufacturer shall not be liable for any damages caused by
improper use.
3.2 Warranty
The warranty shall be void in the event of:
4. Basic safety information
4.1 Follow the instructions in the operating manual
4.2 Warning
▸ Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
▸ If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immediately.
▸ Thoroughly clean the refractometer after each use.
▸ The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
▸ This refractometer is not a toy. Keep out of reach of children.
▸ Make sure that you will not be hit by anything else while you are using the
refractometer, as this could cause serious eye injuries
Net weight
▸ The rubber eyeshade may cause irritation when in prolonged contact with the
skin. If this happens, consult your doctor.
▸ Do not touch the lenses with your fingers.
0,400kg
5. supplied items
After unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
1
6. Before the first use
Remove the protective film ( if present ) from the prism surface [ 2 ] and check that
the rubber eye-cup [ 4 ] is fitted correctly.
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. To ensure correct measure-
ment, the measuring device should be adjusted before measurements are carried
out. Please make sure your hands are dry before handling the measuring device.
The measuring instrument has two measuring ranges. To switch between the two
measuring ranges rotate the housing ring [ 5 ] between the eyepiece [ 4 ] and the
optical tube [ 3 ] .
2
▸ Failure to observe the instructions in the operating manual
▸ Use for purposes other than those described
▸ Modifications or opening the device housing
▸ Mechanical damage and/or damage resulting from media,
liquids, natural wear and tear
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
▸ Every language version includes a non-authoritative translation.
The original German document is the definitive version.
▸ Refractometer
▸ Storage box
▸ Pipette
▸ Adjustment tool
▸ Cleaning cloth
▸ Calibration liquid (Distilled water)
3
4
5
6
Need help?
Do you have a question about the ORA 80 BE and is the answer not in the manual?
Questions and answers