The manual includes how to install and operate the machine under safe condition and explain all the labels printed on the machine. If you encounter any problem, contact your local Antari dealer for assistant immediately. 2. Safety Information...
Please make sure the power outlet is not damaged or loose before plug in the power cord. If the power cord is damaged, it must be replaced by Antari or its local dealers, otherwise the warranty will be void.
Control Settings AF-6/AF-6R Special Effects Fan can be operated in the following modes. The machine can only accept 1 type of signal at a time. When using different control modes at the same time, the machine will work according to built-in control priority: ...
Page 6
W. Remote Setting Use ▲UP and ▼DOWN buttons to select Pair and Unpair Pair/Upair radio wireless remote Quick Turn On or Off Quick Start mode Start Off/On When it is turned on, once power up AF-6 fan, it will run last...
Press ▓STOP button to reset AF-6 to Factory settings Proceed? UID 1ED8 To view RDM’s UID (Unique Identifier) 06020001 Run Time To view total how many minutes or hours this AF-6 has been 0000000H running Machine Status Screen Description AF-6 v1.0...
Fan Speed 6 – 255 Fan 1 – 100% 10. RDM Function The AF-6/AF-6R Special Effect Fan is RDM enabled, allowing control system to configure, monitor and manage. Category RDM Parameter ID’s (Slot 21-22) GET Allowed SET Allowed Value Required 類別...
12. WTR-20 Wireless Remote (Optional) WTR-20 Wireless Remote is an optional accessory for AF-6 Special Effects Fan, it included a W-2 wireless transmitter and a W-2 wireless receiver. If you already purchased the wireless model, it’s ready to use. If you purchase the WTR-20 Wireless Remote afterwards, please follow the instruction below.
Graph 1 Graph 2 Graph 3 1. Please see graph 1, remove the cover from the pointed place; 2. You will see a white cable like graph 2, pull it out and connect to the W-2 wireless receiver; 3. Screw it back to the machine like graph 3 and follow the instruction on 12.3 for pairing. Pair &...
14. Technical Specifications AF-6/AF-6R US Model : AC 100-120V, 50/60Hz 2.5A Rated Voltage EU Model : AC 220-240V, 50/60Hz 1.5A 250W Rated Power 0°C – 40°C (32°F – 104°F) Ambient Temp. Range 2583 CFM (AC 120V/60Hz)、2550 CFM (AC 240V/60Hz) Air Flow 1550 rpm (AC 120V/60Hz)、1530 rpm (AC 240V/60Hz)
3. 包裝內容與檢查 在收到機器後,請立即小心地打開包裝紙箱,檢查所有內容,確認您所購買的機型及配件。如果有任何部 件因運輸過程出現損壞或缺少,請立即連絡經銷商,並以原包裝退回檢查。 3.1 包裝內容 AF-6 AF-6R 1 x AF-6 特效風扇 1 x AF-6R 特效風扇 1 x Neutrik powerCon 電源線 1 x WTR-20 無線控制器 1 x 說明書或掃描機身 QR Code 1 x Neutrik powerCon 電源線 1 x 說明書或掃描機身 QR Code 3.2 選配說明...
Appendix I - Grounding Instruction This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug.
Need help?