USER MANUAL
Micro UPS Series
500VA / 650VA / 850VA / 1000VA / 1250VA / 1650VA / 2200VA
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions that must be followed to avoid fire, property damage, personal injury, or death. The warnings, precautions, and
instructions mentioned in this manual cannot cover all possible conditions and situations that may occur. The operator must understand that common sense and
caution are factors which cannot be built into this product, but must be supplied by the operator. Failure to heed these warnings may affect the warranty.
CAUTION! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
 Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service
equipment with large electrical demands (e.g., air conditioner, refrigerator, copier, etc.). Do not use if the supply cord or plug is damaged. Always unplug the power
cord by the plug, never by tugging at the cable. Do not use with extension cords, an accessory surge protector, into its own output, or "daisy-chain" in serial fashion
with other power strips, UPS, surge protectors, or extension cords.
 Do not remove the cover except to service the battery. When replacing the battery, use the same number and type of battery. No user serviceable parts inside
except for battery. Servicing of user replaceable batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions.
Do not attempt to add external batteries to the UPS.
 Although the UPS may be unplugged from the utility power, hazardous voltage may still be present through the battery. Always turn off the unit and unplug it from
the AC power source before servicing the battery.
 Place the UPS at least 20 cm (7.8 in.) away from other objects to give it adequate airflow around the unit. Do not cover the UPS' cooling vents and avoid exposing
the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Do not allow the UPS to be exposed to moisture,
rain excessive heat, or direct sunlight. Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels (i.e.,
aquariums) on or near the unit. Condensation from liquids can cause the unit to short circuit.
 Install in a temperature and humidity controlled indoor area free of conductive contaminants. Keep on a flat stable surface. If wall mounting, install in a vertical
position to the side of a wall, desk, table, or other stable surface to avoid overheating.
 In the event of an emergency, press the OFF button and disconnect the power cord from the AC power.
 Do not dispose of batteries in a fire, the battery may explode. Do not open or mutilate batteries. Released material is harmful to the skin and eyes and may be toxic.
 Do not attach non-computer-related items, such as medical, life-support, or nuclear equipment, microwave ovens, or vacuum cleaners to UPS. Do not use in any
circumstance that would affect operation or safety of any life support equipment or with any medical applications or patient care.
 Always adhere to all local and national electrical codes.
 Risk of suffocation, choking, or electric shock. Do not allow people with reduced sensory, physical, or mental capacity, children, or pets play with the plastic bag,
packaging material, or battery that was included with your unit.
 Do not use the UPS on any transportation such as airplanes or ships. Shocks or vibrations caused during transit and the damp environment can cause the unit to
short out.
 Do not use the UPS other than its intended use.
 Use tools with insulated handles and wear rubber gloves and boats when servicing. Do not handle any metallic connector before power has been disconnected
when servicing. Always remove metallic objects such as wristwatches and jewelry such as rings when replacing the battery.
 Recycle used batteries in accordance with local ordinances or regulations. Do not dispose battery with regular household waste; batteries are considered hazardous
waste. Remove the battery from the UPS before disposal. Check your local recycling center or waste disposal center to locate your nearest recycling location.
INSTALLING YOUR UPS SYSTEM
OVERVIEW
Thank you for purchasing the Micro UPS Series from Maruson. The Micro UPS provides battery backup during power outages, surge protection, and protection from
power sags. The built-in automatic voltage regulation (AVR) function adjusts minor voltage fluctuations instead of switching over to battery mode for the battery
backed outlets. In the event of a power outage, the UPS will provide temporary power to connected equipment plugged into the Battery-Backed Outlets.
UNPACKING
Inspect the package contents upon receipt. Notify your local dealer if there is any damage. The box should contain the following: (1) UPS and (1) User. Select
models will include (1) Power Cord and/or (1) USB Communication Cable. Power management software for select models can be downloaded online at
www.MarusonUSA.com.
USE GUIDE
 Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral equipment does not exceed the rated capacity. There are many
factors that can affect the amount of power that your computer system will require. For optimal system performance keep the connected load below 80% of the
UPS's rated capacity.
 Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit's rated capacity. If rated unit capacities are exceeded, an
overload condition may occur and cause the UPS unit to shut down and/or the circuit breaker to trip.
 Your new UPS may be used immediately upon receipt. However, recharging the battery for at least eight (8) hours when first receiving the new unit is recommended
to ensure that the battery's maximum charge capacity is achieved. Charge loss may have occurred during shipping and storage. To recharge the battery, simply
leave the unit plugged into an AC outlet. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will
automatically recharge.
 With the UPS unit off and unplugged, connect the computer, monitor, and any equipment into the battery power supplied outlets. Never plug a laser printer,
copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices
will overload and possibly damage the unit or connected device, which will not be covered under warranty.
 To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. To store your UPS for an extended period, fully charge the battery before
storing. Recharge the battery every three months to ensure battery life.
 Battery life and runtime will vary based on battery age, maintenance, altitude, ambient temperatures, power quality of AC power, and frequency of shorts to the UPS.
If the unit requires service or you are having difficulty using the unit, follow these steps:
1. Review the Troubleshooting section of the manual to see if that resolves the issue.
2. Contact your local authorized distributor for support. If you are not able to get ahold of your local authorized distributor, contact Maruson Technical Support at
+1-800-627-8766 or support@marusonusa.com. We're available Monday through Friday, 9 AM to 5 PM (Pacific Time). We will need your model number, serial
number, and description of issue and connected equipment for support.
a. If we are unable to resolve the issue over phone or email, the technician will issue a Return Authorization Number (RMA #) to ship the unit back for repair.
b. If the unit is under warranty, the repairs are free.
3. Pack the unit in the original packaging to avoid damage during transit. Damage sustained during transit and lost packages on the way to or from Maruson are not
covered under warranty. The customer is responsible for all shipping costs (including duties and taxes if outside US) to ship to and from Maruson.
SUPPORT
4. The RMA number must be marked on the outer packaging and return the unit by insured, pre-paid carrier to the address provided by the technician. Packages
Let's Connect
without an RMA number on the outside package and collect shipments will be refused.
@marusontechnology
500VA / 650VA / 850VA / 1000VA Models
1. Input Power Cord: Utility power cord.
2. Input Circuit Breaker: The circuit breaker provides overload and fault protection. In the event of an overload and the circuit breaker trips, turn off the UPS then
unplug at least one piece of equipment from the UPS outlet. Wait 10 seconds before depressing the circuit breaker and turn the UPS on again.
3. Battery-Backed Outlets with Voltage Regulation and Surge Protection: These outlets provide battery power, automatic voltage regulation, and surge
protection. In the event of a major power disturbance, these outlets will continue supplying power to connected equipment until utility power returns or battery is
depleted. The automatic voltage regulation feature adjusts minor voltage fluctuations instead of switching over to battery power.
4. Surge Protected Outlets: These outlets provide surge protection to connected equipment.
5. Phone/Fax/Network Ports (RJ-11/45 Combo Ports): * Suppresses surges in phone, fax, and network cables. Connect the
phone or network cable from the phone or network service to the "IN" port. Connect a second cable from the "OUT" port from the
UPS to your phone, fax, or network equipment. (For 1250VA / 1650VA / 2200VA models only)
6. USB Communication Port: * This port allows connection and communication between the USB port on your computer and UPS
unit. Use the included USB cable to connect your UPS and computer and download the software online if you want to use the
power management feature. (For "S" models only)
7. LED Status Indicators: The LEDs and audible alerts will provide real-time information on the UPS status. See Status Indicators
section for additional information.
8. Power Button: Press the button for to turn the UPS on or off. You will hear 1 short beep when you turn the UPS on or off. This
UPS also has cold start function allowing the UPS to turn on even if there is no utility power as long as there is sufficient battery
power stored.
UPS
Green LED
Orange LED
Status
Line
Solid green
Off
Mode
Flashes every 8 seconds Off
Flashes every 4 seconds Off
Flashes every 2 seconds Off
Flashes every second
Off
Solid green
Off
Battery
Off
Two flashes every 4
Mode
seconds
Off
Off
Off
Constant flashes every
two seconds
Off
Two flashes every 2
seconds, up to 30 times
Off
Fault
Off
Off
Off
Off
Off
Mode
Flashes every 2 seconds Off
FEATURES
1250VA / 1650VA / 2200VA Models
STATUS INDICATORS
Red LED
Audible Alert
Status
Off
Off
UPS normal and battery fully charged
Off
Off
Battery charged at 70% to 90% capacity
Off
Off
Battery charged at 50% to 70% capacity
Off
Off
Battery charged at 30% to 50% capacity
Off
Off
Battery charged at 0% to 30% capacity
Flashes red
Continuous beeping
UPS overload in Line Mode. UPS will shut down at 120%
overload
Turn the UPS off and unplug at least one piece of equipment
before turning the UPS on again. Continue unplugging one
piece of equipment at a time until the UPS stops beeping.
Off
Two beeps every 8
UPS is in normal Battery Mode. Load and battery conditions
seconds up to 10 times
are normal. The audible alert will mute after 10 sets of beeps.
Off
Continuous beeping
UPS overload in Battery Mode. UPS will shut down at 120%
overload
Turn the UPS off and unplug at least one piece of equipment
before turning the UPS on again. Continue unplugging one
piece of equipment at a time until the UPS stops beeping.
Off
Rapid beeping
Battery overtemperature
Off
Two beeps every 2
UPS short-circuited
seconds, up to 30
times
Off
Eight beeps every
Battery overvoltage
second
Solid red
Continuous beeping
Fault detected. Contact support at support@marusonusa.com
if this issue does not go away.
Off
Off
UPS is off
Off
Off
AC normal and battery is charging
Green LED
Orange LED
Red LED
7
8

Advertisement

loading

Summary of Contents for Maruson Micro UPS Series

  • Page 1 If the unit is under warranty, the repairs are free. UPS is off 3. Pack the unit in the original packaging to avoid damage during transit. Damage sustained during transit and lost packages on the way to or from Maruson are not Mode covered under warranty.
  • Page 2 (negative, -) wire to the negative battery terminal of the first battery. ten (10) days of occurrence. If you need to file a claim, contact your local authorized dealer first or fill out the RMA form online from the Maruson website. Terms and conditions apply.

This manual is also suitable for:

Micro ups 500vaMicro ups 650vaMicro ups 850vaMicro ups 1000vaMicro ups 1250vaMicro ups 1650va ... Show all