Inspections And Maintenance; Labeling Diagram - Vestil MPU-AC GEN2 Instruction Manual

Ac-powered modular power unit
Table of Contents

Advertisement

Table of Contents

Inspections and Maintenance:

Review the "Inspections & Maintenance" section of the owner's manual for your product. Put the product into
recommended inspection configuration (e.g. apply maintenance props) before performing the following inspections
and maintenance.
DO NOT inspect the power unit or perform any repairs or maintenance on it unless the selector switch is OFF and
the unit is unplugged from the power source (wall socket).
(A) Before each use, check the cart for any of the following conditions. Restore the unit to normal condition before
returning it to service.
Oil leaks
Pinched or chafed hoses
Damaged electrical cords/hand control
(B) At least once per month, remove the cover and:
• Check the oil level. Oil should be 1in. to 1
& 14) when the piston is completely retracted. Add oil, if necessary. Only use AW-32 hydraulic fluid or its
equivalent. If the oil looks milky, water is present and must be replaced.
• Check for oil leaks. Resolve the issue as described in
• Check hand control and pigtail cord for severe wear.
• Cycle the piston. Watch for binding. Listen for unusual noises. See Troubleshooting.
• Make sure all labels are in place & in readable condition. See
(C) Yearly:
Change the oil at least once a year. The oil should be changed as soon as it darkens, becomes gritty, or
appears milky. Milky appearance indicates the presence of water. Only use AW-32 hydraulic fluid or its
equivalent.

Labeling diagram:

The unit should be labeled as shown in the diagrams. However, label content and location are subject to change
so your product might not be labeled exactly as shown. Thoroughly photograph the unit when you first receive it as
discussed in the
Written Record
record includes a photograph of each label. Replace all labels that are damaged, missing, or not easily readable (e.g.
faded). To order replacement labels, contact the technical service and parts department online at
http://www.vestilmfg.com/parts_info.htm. Alternatively, you may request replacement parts and/or service by calling
(260) 665-7586 and asking the operator to connect you to the Parts Department.
A or B
C
Label 206 (all units; applied to oil reservoir inside
power unit housing): Hydraulic oil specifications
Table of Contents
Rev. 11/27/2018
1
/
in. below the top of the reservoir/tank (item no. 2 on
2
portion of the Inspections and Maintenance section on p. 5. Make sure that your
A: Label 1077 (units
with powered lift
function)
Label 248-251 (all units; applied to front and back of
metal frame):
Copyright 2018 Vestil Manufacturing Co.
Troubleshooting
on p. 21-22.
Labeling diagram
B: Label 1078
(units with
powered tilt
function only)
248: 115V AC, Single-Phase, 60Hz
249: 208-230V AC, 3-Phase, 60Hz
250:460V AC, 3-Phase, 60Hz
251: 208-230V AC, Single-Phase, 60Hz
MPU-AC GEN2, MANUAL