SAFETY INFORMATION
USE OF EXTENSION CORDS WITH
DEHUMIDIFIER
Only use a grounded extension cord that is rated at least 7.8 amps
and has a third-wire ground. When a long extension cord is used to
connect the dehumidifier, a voltage drop occurs. The longer the cord,
the greater the voltage drop. This results in less voltage being supplied
to the dehumidifier and increases the amount of current (amp) draw
or reduces performance. A heavier cord with a larger wire size will
reduce the voltage drop. Be sure to choose a cord that will supply
enough voltage to operate the dehumidifier. The table below indicates
appropriate gauge for extension cords.
Ampere Rating
Not more
More than
than
0
6
6
10
10
12
12
16
WARNING: Keep electrical cords in good condition. Do not use worn, bare, or
frayed cords because they can cause electrical shock.
WARNING: Operating equipment at low voltage can cause it to overheat. Using
an excessively long extension cord can cause the cord to overheat.
Technical Data
Model
Dehumidifying
Capacity
Power Source
Refrigerant/
charge
These specifications are for reference only. For actual data, please refer to the rating label on the back
of the unit.
The dehumidification capacity is rated at a room temperature of 86˚F (30˚C) with a relative humidity of 80%.
The operational temperature is in the range of 44.6˚F (7˚C) to 95˚F (35˚C). If the room temperature is outside of
this range, the unit will not operate normally.
Page 6
Minimum Gauge for Cord Sets
Volts
120V
25 (7.6)
240V
50 (15.2)
18
18
16
14
CCD25JW
CCD35JW
25 Pints/day
35 Pints/day
115V~ 60Hz
115V~ 60Hz
R32/90g
R32/150g
Total Length of Cord in Feet (meters)
50 (15.2)
100 (30.5)
AWG
16
16
16
12
CCD50JW
50 Pints/day
115V~ 60Hz
R32/150g
100 (30.5)
150 (45.7)
200 (61.0)
300 (91.4)
16
14
14
12
14
12
Not Recommended
CCD50PJW
50 Pints/day
115V~ 60Hz
R32/150g

Advertisement