Specifications; Level; Auto Scan Testing; Voltage - Pico Macom PICO-PRO User Manual

Signal analysis meter
Hide thumbs Also See for PICO-PRO:
Table of Contents

Advertisement

Pico Pro Manual 06.qxd

4. SPECIFICATIONS

4.1 LEVEL

Frequency Range:
Resolution Bandwidth:
Channels:
Level Range:
Accuracy:
Input impedance:
Wave detection:

4.2 AUTO SCAN TESTING

Max Channel Scan:
Scan Range:
Scan Speed:
Memory Groups:

4.3 VOLTAGE

Voltage Range:
Accuracy:
Resolution:
4.4 C/N (The measured result is only for reference)
Level Range:

4.5 OTHERS

Dimension:
Weight:
Working Temperature:
Display LCD:

4.6 POWER

DC Supply:
AC Supply:
Battery working hours:
Recharging hours:

4.7 ACCESSORIES

Battery Charger:
RF Input Port:
User Manual
4/10/06
3:20 PM
PICO-PRO
5-870MHz
280kHz ± 50kHz
NTSC CATV & PAL B/G & SUB-Band
30dBµV – 115dBµV (61-870MHz)
33dBµV – 115dBµV (5-60MHz)
±1.5dBµV (under room temperature 27° C)
75Ω (BNC or F connector)
Peak value
100 Channels
All Channels within 46—870MHz
30 Channels/Min
23 Groups (00-22) Each group stores Max 100 Channels
0 – 100VAC
±1.5V
0.1V
80dBuV – 105dBuV
214mm x 94mm X 47mm
1.4 kg
-l5° C – +40° C
128x64 Matrix Super big LCD with back light
DC 7.2V/1.6Ah rechargeable battery
AC 220V/50Hz±10%
longer than 4.5 hours at continuous working mode
12 – 14 hours.
charger 1pc
F type 2pcs
1 copy
Ph: 800-421-6511
www.picomacom.com
Page 9
Pico-Pro User Manual
9
Rev. 03/06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents