Chapter 4 Input Level Versus Channel Loading - Pico Macom PFT-10 Owner's Manual

Pft fiber optic series
Hide thumbs Also See for PFT-10:
Table of Contents

Advertisement

PICO MACOM
Input Level versus Channel Loading
The PFT Transmitters are designed to properly modulate the light output with a specified number of 6
MHz. channels. The PFT-x Specifications shows unit operation with 78 NTSC channels at 15 dBmV
input level each, plus 300 MHz of QAM channels at –6 dB (9 dBmV) input level. If the number of
higher level NTSC signals is reduced, the input levels may be increased to provide the same laser drive
level and end-to-end performance.
The formula to use is: Desired Input Level =
Specified Input Level –10Log (actual channel count /specified channels)
Table of Input Level vs. Channel Count
channels
Input
actually
Delta
level
input
1
18.92 33.92
2
15.91 30.91
3
14.15 29.15
4
12.90 27.90
5
11.93 26.93
6
11.14 26.14
7
10.47 25.47
8
9.89
24.89
9
9.38
24.38
10
8.92
23.92
11
8.51
23.51
12
8.13
23.13
13
7.78
22.78
14
7.46
22.46
15
7.16
22.16
16
6.88
21.88
17
6.62
21.62
18
6.37
21.37
19
6.13
21.13
20
5.91
20.91
CONTACT US
858.546.5050
channels
Input
actually
Delta
level
input
21
5.70 20.70
22
5.50 20.50
23
5.30 20.30
24
5.12 20.12
25
4.94 19.94
26
4.77 19.77
27
4.61 19.61
28
4.45 19.45
29
4.30 19.30
30
4.15 19.15
31
4.01 19.01
32
3.87 18.87
33
3.74 18.74
34
3.61 18.61
35
3.48 18.48
36
3.36 18.36
37
3.24 18.24
38
3.12 18.12
39
3.01 18.01
40
2.90 17.90
Fiber Optic
Chapter 4
channels
Input
actually
Delta
level
input
41
2.79 17.79
42
2.69 17.69
43
2.59 17.59
44
2.49 17.49
45
2.39 17.39
46
2.29 17.29
47
2.20 17.20
48
2.11 17.11
49
2.02 17.02
50
1.93 16.93
51
1.85 16.85
52
1.76 16.76
53
1.68 16.68
54
1.60 16.60
55
1.52 16.52
56
1.44 16.44
57
1.36 16.36
58
1.29 16.29
59
1.21 16.21
60
1.14 16.14
www.picomacom.com
Series
channels
Input
actually
Delta
level
input
61
1.07 16.07
62
1.00 16.00
63
0.93 15.93
64
0.86 15.86
65
0.79 15.79
66
0.73 15.73
67
0.66 15.66
68
0.60 15.60
69
0.53 15.53
70
0.47 15.47
71
0.41 15.41
72
0.35 15.35
73
0.29 15.29
74
0.23 15.23
75
0.17 15.17
76
0.11 15.11
77
0.06 15.06
78
0.00 15.00
79
-0.06 14.94
80
-0.11 14.89
1