Thermistor Failure - U-Line U-2224BEVINT-00A User Manual & Service Manual

Hide thumbs Also See for U-2224BEVINT-00A:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Thermistors
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a
resistance which varies based on surrounding
temperatures. If a faulty thermistor is suspected it may
be tested using an accurate ohmmeter.

THERMISTOR FAILURE

Zone Thermistors
If the zone thermistor in the unit fails the unit will continue
to cool in a back up mode to preserve the integrity of the
contents. The unit will cycle on for ten minutes, then shut
down for forty five minutes. The process will repeat until
the problem is corrected. All other functions of the unit
will continue to operate normally.
Evaporator Thermistors
If an evaporator thermistor fails the unit will rely on a
preset defrost timer during defrost cycles. The unit will
otherwise operate normally. The error will be displayed in
the service mode "Error Log."
This unit has two thermistors. Thermistor one is located
along the right hand side wall inside of the unit and is used
to maintain temperature within the unit.
Thermistor two is located on the back of the evaporator
and is used for defrost purposes.
Thermistor connections must be kept clean. A thermistor
connection that has become corroded can cause
resistance values from the thermistor to change as they
pass through a dirty connection to the board.
It is for that reason that we apply die electric grease to all
of our thermistor connections. Die electric grease will help
to keep thermistor connections clean and dry.
If you change a thermistor in the unit please re-apply die
electric grease to the connection. If you encounter a dirty
thermistor connection, you should replace the thermistor
and the thermistor harness.
Thermistor Resistance Data
Temp (F)
Temp (C)
-40
-31
-22
-13
-4
5
14
23
32
41
50
59
68
77
86
95
104
113
122
131
140
149
158
167
176
* (=/-5%)
65
Nominal Resistance
(OHMS)*
-40
169157
-35
121795
-30
88766
-25
65333
-20
48614
-15
36503
-10
27681
-5
21166
0
16330
5
12696
10
9951
15
7855
20
6246
25
5000
30
4029
35
3266
40
2665
45
2186
50
1803
55
1495
60
1247
65
1044
70
879
75
743
80
631
Thermistor 1