Mitsubishi Electric MUZ-FT25VGHZ-E1 Service Manual page 56

Outdoor unit
Table of Contents

Advertisement

OPERATING PROCEDURE
6. Removing the compressor and 4-way valve
(1) Remove the cabinet and panels. (Refer to section 1.)
(2) Remove the inverter assembly. (Refer to section 2.)
(3) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
(4) Detach the brazed part of the suction and the discharge pipe
connected with compressor.
(5) Remove the compressor nuts.
(6) Remove the compressor.
(7) Detach the brazed part of pipes connected with 4-way valve.
© Copyright 2020 MITSUBISHI ELECTRIC CORPORATION
Published: Jun. 2020. No. OBH865
Made in Japan
(0 MPa).
2
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
PHOTOS/FIGURES
Photo 9
Suction pipe
brazed part
Specifications are subject to change without notice.
56
Discharge pipe
brazed part
Brazed parts of 4-way valve