Fixing The Outdoor Unit In Position; Checking And Testing Operations - Samsung AQ07P2GE Installation Manual

Hide thumbs Also See for AQ07P2GE:
Table of Contents

Advertisement

C
I
OMPLETING THE
NSTALLATION

Fixing the Outdoor Unit in Position

'X' mm
Rubber leg
Model
X
AQ07/09 2G
SH07/09 S2
489
SH07/09 S2A
AQ12 4G
SH12 S4
550
SH12 S4A
SH
APG
504
SH
APGA

Checking and Testing Operations

14
E-
The outdoor unit must be installed on a rigid and stable base to
avoid any increase in the noise level and vibration, particularly if the
outdoor unit is to be installed close to a neighbour.
If it is to be installed in a location exposed to strong winds or at a height,
the unit must be fixed to an appropriate support (wall or ground).
1
Position the outdoor unit so that the air flow is directed towards the
outside, as indicated by the arrows on the top of the unit.
Y
2
Attach the outdoor unit to the appropriate support using anchor bolts.
300
3
If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit, so that the fan can operate correctly.
303
Certainly fix up its rubber leg, in order to prevent its vibration and
251
noise.
To complete the installation, perform the following checks and tests to
ensure that the air conditioner is operating correctly.
1
Review all the following elements in the installation:
Installation site strength
Piping connection tightness to detect any gas leakages
Connection wiring
Heat-resistant insulation of the piping
Drainage
Earthing wire connection
Correct operations (follow the steps below)
2
Press the
Result:
3
Press the
Result:
4
Air flow direction
/
button.
The indicator lights on the indoor unit flash at half-second
intervals.
While the indoor unit opens, the indoor unit fan runs to start.
/
button.
The outdoor unit operates in cooling or heating mode as
following the room temperature.
Press the
/
air flow blades work properly.
button and check that the