INSTALLATION MANUAL
1500KNGK / 1500KPGK
Gas Conversion Kits for 1500K & 1600K ONLY
Kit Contents
• 1 Pilot injector
• 1 Main burner injector
• 1 Minimum rate bypass screw
• 1 Set of conversion labels
Tools Required
• 7/16" socket driver with extension to install main
burner injector
• Small (jewelers size) fl at blade screwdriver, to set pres-
sure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove bypass screw
• Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
• Manometer, to set pressure
• Wrenches, to disconnect gas line (optional step)
• Phillips (+) screwdriver, to remove burner module
(optional step)
• 1/4" inner diameter tubing
Specifi cations
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
* This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
4008198-02
©2020, Miles Industries Ltd.
L1 Series
1500KN
1500KP
1600KN
1600KP
Natural
Propane
0-4,500 feet*
30,000
30,000
19,000
21,000
3.5"
9.0"
5"
11"
10"
14"
DMS#36
DMS#51
51
30
220
160
 WARNING
This conversion kit shall be installed by
a qualifi ed service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fi re, explosion
or production of carbon monoxide
may result causing property damage,
personal injury or loss of life. The
qualifi ed service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specifi ed in the
manufacturer's instructions supplied with
the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
General Notes Regarding Conversion
The conversion may be done before or after the
appliance is installed. However, if the unit has been
installed and wall fi nish applied, the burner module
must be removed from the fi replace (see page 3).
Note that the gas must be connected to set the
manifold pressure.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Valor L1 1500KNGK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Miles Valor L1 1500KNGK

  • Page 1 Maximum Supply Pressure (in w.c.) 10” 14” Main Burner Injector Marking DMS#36 DMS#51 Pilot Injector Marking Min. Rate By-Pass Screw * This appliance is certifi ed for use from 0–4500 feet. For altitudes above 4500 feet, see local codes. 4008198-02 ©2020, Miles Industries Ltd.
  • Page 2 Prepare Appliance Rotate Air Shutter Stopper 1. If the fi replace is already installed, remove any in- Adjust the air shutter stopper for your desired fuel. stalled trims, fronts, doors, and window. Remove the two screws holding the stopper in place, and rotate the stopper to the appropriate position.
  • Page 3 Replace Pilot Injector Remove Burner Module 1. Remove pilot shield (2 screws). This section is only required if the appliance has been installed and wall fi nish has been applied. If not, the steps in the next section, “Replace the Minimum Rate Bypass Screw”...
  • Page 4 Replace Minimum Rate Bypass Screw Set Manifold Pressure 1. Locate and remove the bypass screw from the valve 1. Fit a manometer to the manifold pressure test tap and discard (this screw may be covered by a sticker). on the valve using 1/4” ID tubing —see fi gure below. Note the bypass screw may have require either a Manifold fl...
  • Page 5 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel.
  • Page 6: Directives D'installation

    DIRECTIVES D’INSTALLATION Série L1 1500KNGK/1500KPGK—Trousse de conversion de gaz pour 1500K et 1600K SEULEMENT Contenu du kit  AVERTISSEMENT • 1 Injecteur de veilleuse • 1 Injecteur de brûleur Ce kit de conversion doit être installé par • 1 Vis d’indice minimum une agence de service qualifi...
  • Page 7 Préparez l’appareil Pivotez le butoir d’obturateur 1. Si le foyer est déjà installé, enlevez le pare-étince- Pivotez le butoir d’obturateur selon le gaz qui sera lles, les portes des côtés, la plinthe, la fenêtre et le utilisé. Dévissez les deux vis retenant le butoir de lit d’alimentation (bûches, verre, etc.).
  • Page 8 Remplacez l’injecteur de la veilleuse Enlevez le module du brûleur (si nécessaire) 1. Enlevez l’écran de veilleuse (2 vis). Si la finition du mur devant l’appareil n’est pas posée, allez à la section suivante pour remplacer la vis d’indice minimum de la soupape à gaz. Autrement, enlevez le module du brûleur pour avoir accès à...
  • Page 9 Remplacez la vis d’indice minimum Réglez et vérifi ez la pression d’admission Accédez à la vis sur la soupape par le trou d’accès se 1. Fixez un manomètre à la connexion de vérifi cation trouvant sur la paroi avant de l’appareil. de pression d’admission sur la soupape à...
  • Page 10 Parce que nous favorisons une politique de développement continu, certains détails de la présente publication peuvent varier. Conçue et fabriquée par / pour Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tél. 604-984-3496 Téléc. 604-984-0246...

This manual is also suitable for:

Valor l1 1500kpgk