Advertisement

Quick Links

Installation Manual
G3.5
with
Canadian Patent 2,717,779 Issued October 24 2017
US Patent 10,060,624 Issued August 28 2018
US Patent   1 0,935,246 Issued March 2 2021
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings
exactly could result in serious
injury, death, or property damage.
Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
DANGER
4005344-14
©2021, Miles Industries Ltd.
Direct Vent Insert
Gas Fireplace
natural gas
propane gas 700XP
Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
Hot glass
will cause burns.
Do not touch glass
until cooled.
Never allow children
to touch glass.
700XN
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fi re department.
A barrier designed to reduce
the risk of burns from the hot
viewing glass is provided with this
appliance and must be installed for
the protection of children and
other at-risk individuals.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Valor G3.5 700XN and is the answer not in the manual?

Questions and answers

Summary of Contents for Miles Valor G3.5 700XN

  • Page 1 Do not touch glass viewing glass is provided with this until cooled. appliance and must be installed for the protection of children and Never allow children to touch glass. other at-risk individuals. 4005344-14 ©2021, Miles Industries Ltd.
  • Page 2 Note: Natural gas, in its original state, contains Benzene. The information contained in this manual is believed to be correct at the time of printing. Miles Industries Ltd. reserves the right to change or modify any information or specifi cations without notice. Miles Industries Ltd.
  • Page 3: Table Of Contents

    Welcome to Valor ® This appliance has been professionally installed by: Please read this manual BEFORE Dealer Name: ________________________________ installing and operating this Phone:______________________________________ appliance. Fireplace Safety ..........4 Window Re-Installation & Checking ....... 21 Remote Control Pairing ..........22 Specifi...
  • Page 4: Fireplace Safety

    Fireplace Safety This manual contains very important information about the safe installation and operation of the fi replace. Read and understand all instructions carefully before installing and operating the fi replace. Failure to follow these instructions may result in possible fi re hazard and will void the warranty. Replacement manuals are available by contacting the Valor Customer Service at 1-800-468-2567, or by visiting valorfi...
  • Page 5 Fireplace Safety Glass window Intended use • This appliance is designed and approved as a supple- mental heater and provides the potential for most en-  WARNING ergy conservation when used while attended. The use Do not operate this appliance with the of an alternate primary heat source is advisable.
  • Page 6: Specifications

    Specifications Approval & Codes Supply Gas This appliance is certifi ed to ANSI Z21.88/CSA 2.33 Heater engine 700XN uses natural gas. American National Standard / CSA Standard for Vented Heater engine 700XP uses propane gas. Gas Fireplace Heaters for use in Canada and USA, and The supply pressure must be between the limits shown to CGA 2.17-91 High Altitude Standard in Canada.
  • Page 7: Kits & Accessories

    Kits & Accessories Required Kits Optional Accessories Fuel Beds (choose one) Riser Trims (choose one) 725RTB 700XDWK Driftwood Log Set Riser trim black for 3 sided fronts 793RTB 700XDGM Murano Glass 793RTV Riser trim vintage iron for 3 sided fronts Liners (choose one) Backing Plates (choose one) 705LSLV3...
  • Page 8: Dimensions

    Dimensions Dimensions 28-5/8” (727 mm) IMPORTANT: See below for minimum cavity dimensions! 21-1/4” (540 mm) Fan box: 3” (76 mm) Optional fan 3” 3” 9” (76 m m m) (76 mm) 13” (228 mm m ) (330 mm) 1-1/2” (38 mm) 4”...
  • Page 9: Installation Planning

    Installation Planning Clearances Combustible Mantel—Left Side View Sidewall Clearances With optional Fan: depth 4” (102 mm) Do not put +3” (76 mm) furniture or objects within 36” (914 mm) of the front of appliance Minimum distance from side of appliance (liner box) to Non-combustible hearth combustible wall: 4”...
  • Page 10: Before Installation

    Installation Planning Before Installation  Caution Only qualified, licensed, or trained personnel should install this appliance. Installer - READ THIS FIRST! 1. YOU NEED TO KNOW FROM THE HOMEOWNER: • What accessories (surround, screen, fan*, etc) will be installed 2. Unpack the appliance, removing all items packed inside and around it.
  • Page 11: Concept

    Installation Planning Concept Intended Installation This appliance may ONLY be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. DO NOT install into combustible construction. This appliance is NOT APPROVED for installation with a zero clearance kit.
  • Page 12: Venting

    Venting Concept Typical Vent Installation Terminal Cap NOTE: Flexible co-linear vent pipes may only be installed into existing non-combustible solid-fuel burning fi replaces and chimneys. Flashing See list of approved Venting Accessories on page 41 of this manual. The appliance must not be connected to a chimney fl...
  • Page 13: Preparation

    Preparation Existing Fireplace Preparation Existing Fireplace Preparation Gas Line Routing A few points must be considered before inserting Plan the routing of the gas line before proceeding. the 700 into an existing fi replace cavity. Generally, no Utilize the existing hole for the gas line of the factory- modifi...
  • Page 14: Installation

    Installation Window and Fan Remove Window Install Fan Kit (if used) The window is held in place by a spring-loaded lever on If the 795CFKV2 Circulating Fan Kit (blower) is to be each side. To remove the window: installed, we suggest that you do it now. 1.
  • Page 15: Venting

    Installation Venting Connect Venting IMPORTANT: This appliance’s venting system is room sealed and therefore does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process.
  • Page 16: Gas Supply

    Installation Gas Supply Connect Gas Supply The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve The gas supply inlet connection is a 1/2” NPT female. during any pressure testing of the gas supply piping Gas shut-off...
  • Page 17 Installation Gas Supply Inlet Connection 2. Install alternate elbow (not supplied). The appliance is sup- plied with a fl ared elbow 6-3/8” connector fi tted onto the (162 mm) valve and a fl ex connec- tor supplied loose to be 3/8”...
  • Page 18: Liners

    Installation Liners Remove and re-install burner (if necessary) 2. Place the rear panel against the back of the fi rebox, on the ledge at bottom, behind the burner. The ceramic panels can be installed without removing the burner. However, you can remove the burner for additional space if desired.
  • Page 19: Fuel Beds

    Installation Fuel Beds Install Driftwood Kit 700XDWK 2. Place the right log on the right side of the ceramic burner inserting the two pegs of the log in the holes Material required of the burner. • Driftwood Kit, which contains: •...
  • Page 20: Install Decorative Glass Murano 700Xdgm

    Installation Fuel Beds Install Decorative Glass Murano 700XDGM 5. Carefully spread the glass on top of the burner within the platform opening. Material required • Decorative Glass Murano kit, which contains: • 1 glass platform • 1 glass piece for pilot cover •...
  • Page 21: Window Re-Installation & Checking

    Installation Window Re-Installation & Checking Refi t and Check Window  WARNING 1. Place the window in its bottom railing and push its top against the fi rebox. Ensure to remove any The window unit must be correctly particles in the railing before installing the window. installed, fastened and sealed after servicing or serious bodily injury and/or Window...
  • Page 22: Remote Control Pairing

    Installation Remote Control Pairing Synchronize Remote Control 4. With a sharp object, press and hold the receiver’s RESET button until you hear one short and one long The receiver and the handset of the remote control beep. Release the reset button after the second beep. system must be initially synchronized before the fi...
  • Page 23: Check Operation And Aeration

    Installation Check Operation and Aeration Check Operation 3. Loosen the air shutter nuts, adjust and re-tighten. Turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs is achieved—see the Remote Control Use starting on page Close Adjust Aeration (if necessary) Light the fi...
  • Page 24: Accessories

    Installation Accessories Install Side Shrouds The side shrouds are required to install the front on the appliance. They are supplied with the engine. Fit them to the appliance outer case as indicated (2 screws/side). See instructions supplied with the front trim for installation of trim.
  • Page 25: Remote Control Holder

    Installation Remote Control Holder Install Remote Control Handset Wall Holder The remote control kit for this fi replace comes complete with a wall-mounted holder. This holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall.
  • Page 26: Gv60 Wiring Diagram

    Installation GV60 Wiring Diagram MAN Knob Main Valve Knob Optional Wall Switch Combination Control Valve black Interruptor Block ON/OFF Switch Connector Thermocouple yellow Antenna Receiver Battery Holder RESET Button Optional 795CFKV2 Control Module...
  • Page 27: Approved Venting Components

    Approved Venting Components Approved Direct Vent Suppliers for Valor Models 700 , 739 , 780 and 785 Venting Parts Code / availability by Manufacturer Venting Parts Description 4DVC 940264 HSDV4658- Standard Co-axial 46DVA-VC 4DT-VT — — 4DH-1313 — 940364 1313 940206LP High Wind Co-axial 46DVA-VCH...
  • Page 28: Appendix A-Lighting Instructions

    Appendix A—Lighting Instructions FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly causing property damage, personal injury or loss of life. . To save gas, turn the pilot off when not using the appliance for a prolonged period of time. WHAT TO DO IF r’s phone.
  • Page 29: Appendix B-Remote Control Operation

    Appendix B—Remote Control Operation Initial Pairing Before the remote control can be used with the fi replace, it must be paired. See page 22. Radio Frequency Turn Fireplace ON 315 MHz for USA and Canada. Press buttons until you hear a short beep;...
  • Page 30 Appendix B—Remote Control Operation Setting ºC/24-hr or ºF/12-hr Manual Mode M A N clock Manual ame height adjustment. In MAN mode, press buttons Daytime Temperature Mode until temperature / clock display TEMP changes from When pilot is lit, room temperature is measured and compared to set °F / 12-hour °C / 24-hour...
  • Page 31 Appendix B—Remote Control Operation Circulating Fan Operation Setting Program Timers (if equipped) You can program two periods of time between 12 am Circulating fan has 4 speed levels from and 11:50 pm in each 24-hour cycle. low to high (1 to 4 bars). Programs P1 and P2 must be set in the following order Press SET to scroll to .
  • Page 32 Appendix B—Remote Control Operation Setting P2 high and low temperature times. Repeat same steps as Setting P1. When all settings are complete, press to save them. Timer Programming Example (default temperatures shown) 6:00 am 8:00 am 4:00 pm 10:00 pm 6:00 am high temp low temp...
  • Page 33: Appendix C-Spare Parts

    Appendix C—Spare Parts Part Part Description Description Number Number AutoFire Exhaust slide assembly 4006540 Auxiliary battery holder & cable Exhaust slide gasket 4001662 Battery holder 4006553 Shrouds (2) 4003295AZ Battery holder cable 1500mm 4006552 Side brick anchors (2) 4001283 Handset GV60 MAX 4002251 LH Explosion relief assembly 4003681...
  • Page 34 Appendix C—Spare Parts Part Description Number Valor red brick 4003217 Right side panel Ledgestone V3 4008185 Refl ective Glass 4004706 Ceramic fl uted black 4003209 Valor red brick 4003218 GV60 Valve repair kit 4004544 2.5-4.5” hose clamp (2) 4000768...
  • Page 35 Appendix C—Spare Parts 48 50 51 700XDWK 36 6 38 39 700XDGM 33a, 30–31 25–28...