Download Print this page

Technical Data - Whirlpool JT 359/BL Service Manual

Advertisement

S E R V I C E

Technical data

Product dimensions
Height
Width
Depth
Cavity dimensions
Height
Width
Depth
Cavity volume
Turntable diameter
Weight
Net
Electrical
Voltage
Frequency
Power
Output power MW
Grill
Forced air
Microwave frequency
5 power levels
Error codes
Certain fault conditions are indicated by an error code.
The following codes are implemented:
Error code
ERR 1
MW Relay error
ERR 2
Keyboard error
ERR 3
Cavity temperature sensor error
ERR 4
Ambient temperature sensor error
Magnetron temperature sensor error
ERR 5
Switched mode power supply (SMPS) error
ERR 7
Humidity sensor error
ERR 8
EEPROM error
Whirlpool Europe
Customer Service
Description
JT 359/BL
8587 359 99491
377
493
487
210
395
370
31
360
31.4
230 - 240
50
1000
1200
1500
2450
16.08.2004 / Page 3
Doc. No: 4812 714 15491
mm
mm
mm
mm
mm
mm
l
mm
kg
V
Hz
W
W
W
MHz

Advertisement

loading