  • Page 1 Owner’s Manual GENERATOR EU3000is Click to Save As See page 89 for Initial Use Instructions 2016 Honda Motor Co., Ltd. -All Rights Reserved...
  • Page 2 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. California Proposition 65 This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm Exhaust contains poisonous carbon monoxide gas that can build up to...
  • Page 3 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely.
  • Page 4 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual.
  • Page 5: Table Of Contents

    CONTENTS GENERATOR SAFETY ................6 IMPORTANT SAFETY INFORMATION ..........6 Operator Responsibility..............6 Carbon Monoxide Hazards..............6 Electric Shock Hazards ..............7 Fire and Burn Hazards ...............7 Refuel With Care ................8 SAFETY LABEL LOCATIONS..............9 CONTROLS & FEATURES...............10 COMPONENT & CONTROL LOCATIONS...........10 CONTROLS...................12 Engine Switch ..................12 Starter Grip..................12 Fuel Valve Lever................13 Choke Knob ..................13...
  • Page 6 CONTENTS OPERATION .....................21 SAFE OPERATING PRECAUTIONS.............21 STARTING THE ENGINE ..............22 STOPPING THE ENGINE ..............26 AC OPERATION..................27 AC Applications................28 AC PARALLEL OPERATION..............29 AC Parallel Operation Applications ..........31 DC OPERATION..................33 ECO-THROTTLE SYSTEM ..............36 STANDBY POWER ................37 Connections to a Building’s Electrical System ......37 System Ground ................37 Special Requirements..............38 SERVICING YOUR GENERATOR............39...
  • Page 7 CONTENTS TRANSPORTING..................66 TAKING CARE OF UNEXPECTED PROBLEMS ........67 ENGINE WILL NOT START..............67 ENGINE LACKS POWER..............67 NO POWER AT THE AC RECEPTACLES..........68 NO POWER AT THE DC RECEPTACLE ..........68 TECHNICAL INFORMATION ..............69 Serial Number Location ..............69 Carburetor Modification for High Altitude Operation....70 Emission Control System Information...........71 Air Index ...................74 Specifications ...................75...
  • Page 8: Generator Safety

    GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all the instructions in this manual and on the generator.
  • Page 9: Electric Shock Hazards

    • Do not connect to a building’s electrical system unless an isolation switch has been installed by a qualified electrician. • Use only a Honda approved parallel operation cable kit (optional equipment) when connecting two EU3000is generators for parallel operation. • Never connect different generator models.
  • Page 10: Refuel With Care

    GENERATOR SAFETY Refuel With Care • Gasoline is extremely flammable, and gasoline vapor can explode. • Do not refuel during operation. • Allow the engine to cool if it has been in operation. • Refuel only outdoors in a well-ventilated area and on a level surface. •...
  • Page 11: Safety Label Locations

    GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement.
  • Page 12: Controls & Features

    CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls. PARALLEL OPERATION OUTLETS DC RECEPTACLE DC CIRCUIT OUTPUT PROTECTOR INDICATOR AC CIRCUIT PROTECTORS OVERLOAD ALARM OIL ALERT INDICATOR ENGINE SWITCH CHOKE KNOB AC RECEPTACLES...
  • Page 13 CONTROLS & FEATURES SPARK PLUG CAP FRONT HANDLE MUFFLER OIL FILLER CAP AIR CLEANER OIL DRAIN PLUG OIL MAINTENANCE COVER LEFT SIDE MAINTENANCE COVER FUEL TANK CAP STARTER GRIP REAR HANDLE GROUND TERMINAL...
  • Page 14: Controls

    CONTROLS & FEATURES CONTROLS Engine Switch The engine switch controls the ignition system, and it operates the electric starter. OFF – Stops the engine. The START engine switch key can be removed/inserted. ON – Running position, and for starting with the recoil starter. ENGINE SWITCH START –...
  • Page 15: Fuel Valve Lever

    CONTROLS & FEATURES Fuel Valve Lever The fuel valve lever is located on the control panel. The fuel valve must be in the ON position for the engine to run. After stopping the engine, turn the fuel valve to the OFF position. FUEL VALVE LEVER CHOKE KNOB Choke Knob...
  • Page 16: Eco-Throttle Switch

    ECO-THROTTLE SWITCH Parallel Operation Outlets These outlets are used for connecting two EU3000is generators for parallel operation (see page 29). A Honda approved parallel operation cable kit (optional equipment) is required for parallel operation. This kit can be purchased from an authorized Honda generator dealer.
  • Page 17: Ac Circuit Protectors

    CONTROLS & FEATURES AC Circuit Protectors The AC circuit protectors will automatically switch to OFF if there is a short circuit or a significant overload of the generator at the 120 V 20 A receptacle or 120 V 30 A locking plug receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.
  • Page 18: Features

    CONTROLS & FEATURES FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. OUTPUT INDICATOR (GREEN) Overload Alarm (Indicator) If the generator is overloaded (in excess of 3.0 kVA), or if there is a short circuit in a connected appliance, the overload alarm (red) will come ON.
  • Page 19: Oil Alert Indicator

    CONTROLS & FEATURES ® Oil Alert Indicator ® The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator (red) comes on and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
  • Page 20: Ground Terminal

    CONTROLS & FEATURES Ground Terminal The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
  • Page 21: Before Operation

    BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it.
  • Page 22: Check The Engine

    BEFORE OPERATION To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Before beginning your pre-operation checks, be sure the generator is on a level surface and the engine switch is in the OFF position.
  • Page 23: Operation

    OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 19). For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.
  • Page 24: Starting The Engine

    OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Operating this generator less than 3 feet (1 meter) from a building or other obstruction can cause overheating and damage the generator.
  • Page 25 OPERATION 3. Make sure the Eco-Throttle ECO-THROTTLE SWITCH switch is in the OFF position, or more time will be required for warm-up. CHOKE KNOB 4. To start a cold engine, pull the choke knob out to the CLOSED position. To restart a warm engine, leave the choke knob in the OPEN position.
  • Page 26 OPERATION 6. If the choke knob was moved to CHOKE KNOB the CLOSED position to start the engine, gradually push it to the OPEN position as the engine warms up. OPEN 7. If you wish to use the Eco-Throttle system, turn the ECO-THROTTLE SWITCH Eco-Throttle switch to the ON position after the engine has...
  • Page 27 OPERATION 5. Pull the starter grip lightly until STARTER GRIP you feel resistance; then pull briskly in the direction of the arrow as shown. Do not allow the starter grip to snap back against the generator. Return it gently to prevent damage to the starter.
  • Page 28: Stopping The Engine

    OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1. Turn off or disconnect all appliances that are connected to the generator or the parallel operation kit. 2.
  • Page 29: Ac Operation

    OPERATION AC OPERATION Before connecting an appliance to the generator, make sure that it is in good working order and that its electrical rating does not exceed that of the generator. Most motorized appliances require more than their electrical rating for startup.
  • Page 30: Ac Applications

    OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
  • Page 31: Ac Parallel Operation

    This is normal if the overload alarm (red) goes off within 4 seconds. If the overload alarm (red) stays on, consult your generator dealer. 1. Connect the parallel operation kit between the two EU3000is generators following the instructions supplied with the kit. PARALLEL OPERATION KIT (optional equipment) 2.
  • Page 32 OPERATION 3. Plug in the appliance following the instruction provided with the parallel operation cable kit. 4. Turn on the appliance. If the generators are overloaded (see page 32), or if there is a short circuit in a connected appliance, the overload alarm (red) will go ON. The overload alarm (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF .
  • Page 33: Ac Parallel Operation Applications

    • Never connect different generator models and types. • Use only a Honda approved parallel operation kit (optional equipment) when connecting two EU3000is generators for parallel operation. • Never connect or remove the parallel operation kit when the generator is running.
  • Page 34 OPERATION Most appliance motors require more than their rated wattage for startup. Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator. Maximum power in parallel operation is: 6.0 kVA For continuous operation, do not exceed the rated power.
  • Page 35: Dc Operation

    DC Current Eco-Throttle switch (Do not use the AC output) Model EU3000is 12 A approximately 4 A Connecting the battery charging cable (optional equipment): 1. Before connecting the battery charging cable (optional equipment) to a battery that is installed in a vehicle, disconnect the vehicle battery ground cable from the negative (–) battery terminal.
  • Page 36 OPERATION 2. Plug the battery charging cable into the DC receptacle of the generator. 3. Connect the red lead of the battery charging cable to the positive (+) battery terminal and the black lead to the negative (–) battery terminal. BATTERY CHARGING CABLE (optional equipment) RED LEAD...
  • Page 37 OPERATION YELLOW INDICATOR DC RECEPTACLE DC CIRCUIT PROTECTOR Disconnecting the battery charging cable: 1. Stop the engine. 2. Disconnect the black lead of the battery charging cable from the negative (–) battery terminal. 3. Disconnect the red lead of the battery charging cable from the positive (+) battery terminal.
  • Page 38: Eco-Throttle System

    OPERATION ECO-THROTTLE™ SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco-Throttle™...
  • Page 39: Standby Power

    OPERATION STANDBY POWER Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
  • Page 40: Special Requirements

    OPERATION Special Requirements Keep all cooling holes open and clear of debris, mud, water, etc. Cooling holes are located on the side panel, the control panel, and the bottom of the generator. If the cooling holes are blocked, the generator may overheat and damage the engine, inverter, or windings.
  • Page 41: Servicing Your Generator

    SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
  • Page 42: Maintenance Safety

    SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Improper maintenance can cause an unsafe condition.
  • Page 43: Maintenance Schedule

    SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) First Every Every Every Perform at every indicated month Each month year or operating hour interval, months months page whichever comes first. 20 Hrs. 300 Hrs. ITEM 50 Hrs. 100 Hrs. Engine oil Check level Change...
  • Page 44: Refueling

    SERVICING YOUR GENERATOR REFUELING With the engine stopped, remove the fuel tank cap and check the fuel level. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel.
  • Page 45: Fuel Recommendations

    SERVICING YOUR GENERATOR FUEL LEVEL GAUGE UPPER LEVEL MARK (RED) FULL TETHER EMPTY FUEL STRAINER UPPER LEVEL MARK (RED) FUEL TANK CAP After refueling, reinstall the fuel tank cap securely. FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher.
  • Page 46: Engine Oil Level Check

    SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped. 1. Open the oil maintenance cover. 2. Remove the oil filler cap. 3. Check the oil level. If it is below the upper limit, fill with the recommended oil (see page 46) to the upper limit.
  • Page 47: Engine Oil Change

    SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1. Open and remove the oil maintenance cover. 2. Place a suitable container below the engine to catch the oil, then remove the drain plug and sealing washer, remove the oil filler cap, and drain the oil.
  • Page 48: Engine Oil Recommendations

    SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W—30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range.
  • Page 49: Air Cleaner Service

    SERVICING YOUR GENERATOR AIR CLEANER SERVICE AIR CLEANER COVER CLIPS 1. Use a screwdriver to loosen the latch and open the left side maintenance cover. 2. Unsnap the air cleaner cover clips, and remove the air cleaner cover. CLIPS FOAM AIR FILTER 3.
  • Page 50: Foam Air Filter Cleaning

    SERVICING YOUR GENERATOR FOAM AIR FILTER CLEANING A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule.
  • Page 51: Spark Plug Service

    SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plug: BPR6ES (NGK) W20EPR-U (DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
  • Page 52 SERVICING YOUR GENERATOR 6. Visually inspect the spark plug. SIDE ELECTRODE Replace it if the electrodes are 0.028–0.031 in worn or if the insulator is (0.7–0.8 mm) cracked, chipped, or fouled. 7. Measure the spark plug SEALING electrode gap with a wire-type WASHER INSULATOR feeler gauge.
  • Page 53: Spark Arrester Service

    SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: 1.
  • Page 54 SERVICING YOUR GENERATOR 6. Remove the three 5 mm bolts, and remove the exhaust tail pipe and the spark arrester. EXHAUST TAIL PIPE SPARK ARRESTER 5 mm BOLTS 7. Use a brush to remove carbon deposits from the spark arrester screen.
  • Page 55 SERVICING YOUR GENERATOR 9. Install the lower muffler protector, the rear under plate, and the rear handle in the reverse order of removal. HOOK LOWER MUFFLER PROTECTOR LOWER MUFFLER PROTECTOR REAR HANDLE REAR UNDER PLATE HOOK Install the lower muffler protector inside the hook securely. 10.
  • Page 56: Sediment Cup Cleaning

    SERVICING YOUR GENERATOR SEDIMENT CUP CLEANING The sediment cup prevents water that may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1. Turn the engine switch to the OFF position. 2.
  • Page 57 SERVICING YOUR GENERATOR 8. Unscrew the sediment cup. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away •...
  • Page 58: Battery Service

    SERVICING YOUR GENERATOR BATTERY SERVICE Your generator’s engine charging system charges the battery while the engine is running. However, if the generator is only used periodically, the battery must be charged monthly to maintain the battery service life. The battery contains sulfuric acid (electrolyte), which is highly corrosive and poisonous.
  • Page 59 SERVICING YOUR GENERATOR Battery Removal WARNING: Battery posts, terminals, and related accessories contain lead and lead components. Wash hands after handling. 1. Remove the four 6 mm cap nuts, and remove the front cover. COLLAR (4) FRONT COVER 6 mm CAP NUTS 2.
  • Page 60 SERVICING YOUR GENERATOR Battery Charging The battery will expel explosive hydrogen gas when overcharged. A spark or flame can cause the battery to explode with enough force to kill or seriously hurt you. Always use a regulated charger that provides the correct charging current to prevent overcharging.
  • Page 61 SERVICING YOUR GENERATOR Battery Installation 1. Install the battery in the generator. 2. Connect the battery positive (+) cable to the battery positive (+) terminal first and tighten the bolt securely. 3. Slide the battery boot over the positive (+) cable and terminal. 4.
  • Page 62: Fuse

    SERVICING YOUR GENERATOR FUSE If the fuse is blown, the starter motor won’t operate. 1. Turn the engine switch to the OFF position. 2. Remove the four 6 mm cap nuts and the front cover. COLLAR (4) FRONT COVER 6 mm CAP NUTS 3.
  • Page 63: Storage

    STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again.
  • Page 64 STORAGE Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline stabilizer Fill with fresh gasoline and add gasoline 2 months to 1 year stabilizer Drain the carburetor float bowl (page 63).
  • Page 65 STORAGE Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away •...
  • Page 66: Engine Oil

    STORAGE Engine Oil Change the engine oil (see page 45). Engine Cylinder 1. Remove the spark plug (see page 49), and pour approximately one teaspoon (5 cc) of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug.
  • Page 67: Storage Precautions

    STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer.
  • Page 68: Transporting

    TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil or fuel may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle.
  • Page 69: Taking Care Of Unexpected Problems

    TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause Correction Fuel valve lever OFF . Turn lever ON (p. 22). Engine switch OFF . Turn engine switch to ON (p. 23). Out of fuel. Refuel (p. 42). Bad fuel; generator stored without Drain fuel tank and carburetor treating or draining gasoline, or (p.
  • Page 70: No Power At The Ac Receptacles

    TAKING CARE OF UNEXPECTED PROBLEMS NO POWER AT THE AC RECEPTACLES Possible Cause Correction Output indicator is OFF , and Check AC load. Stop and restart overload alarm is ON. the engine. Check the cooling air inlet. Stop and restart the engine. AC Circuit protector tripped.
  • Page 71: Technical Information

    TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries. Frame serial number: Date purchased:...
  • Page 72: Carburetor Modification For High Altitude Operation

    TECHNICAL INFORMATION Carburetor Modification for High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
  • Page 73: Emission Control System Information

    TECHNICAL INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
  • Page 74 TECHNICAL INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. • Hard starting or stalling after starting. • Rough idle. • Misfiring or backfiring under load. •...
  • Page 75 TECHNICAL INFORMATION U.S. EPA and CARB Compliance Your new Honda complies with both the U.S. EPA and State of California emission regulations. In all areas of the United States your power equipment engine is designed, built, and equipped to meet the U.S.
  • Page 76: Air Index

    TECHNICAL INFORMATION Air Index (Models sold in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines.
  • Page 77: Specifications

    TECHNICAL INFORMATION Specifications Dimensions Model (Type) EU3000is1 Description code EZGF Length 25.9 in (658 mm) Width 17.6 in (447 mm) Height 22.0 in (558 mm) Dry mass [weight] 130.7 lbs (59.3 kg) Engine Model GX200T2 Engine type 4-stroke, overhead valve, single cylinder Displacement 12.0 cu-in (196 cm [Bore ×...
  • Page 78: Wiring Diagram

    TECHNICAL INFORMATION Wiring Diagram...
  • Page 79: Consumer Information

    CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: http://powerequipment.honda.com/dealer-locator Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.com/support/shop-manuals Parts Catalog...
  • Page 80: Customer Service Information

    CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help.
  • Page 81: Distributor's Limited Warranty

    (from date of original retail purchase) PRIVATE COMMERCIAL/ RESIDENTIAL (2) RENTAL/INSTITUTIONAL EU3000is generator 36 months 36 months (1) Length of Warranty: Batteries supplied with applicable products as standard, original equipment are covered by this warranty for a period of 12 months (private residence) or 3 months (commercial/ rental/institutional use) from the date of original retail product purchase.
  • Page 82 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S.
  • Page 83 CONSUMER INFORMATION Exclusions: 1. Any damage or deterioration resulting from the following: – Neglect of the periodic maintenance as specified in the product owner’s manual – Improper repair or maintenance – Operating methods other than those indicated in the product owner’s manual –...
  • Page 84 CONSUMER INFORMATION Honda Parts, Accessories, and Apparel This warranty is limited to Honda Power Equipment parts, accessories, and apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia 30005-8847. PRODUCTS COVERED LENGTH OF WARRANTY BY WARRANTY (from date of original retail purchase) PRIVATE COMMERCIAL/...
  • Page 85 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment part, accessory, or apparel, or the Honda Power Equipment on which the accessory or part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S.
  • Page 86: Emission Control System Warranty

    CONSUMER INFORMATION Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California (models certified for sale in California only) emission regulations. American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the United States and its territories.
  • Page 87 CONSUMER INFORMATION Owner’s Warranty Responsibility As the power equipment engine owner, you are responsible for completing all required maintenance listed in your owner’s manual. Honda recommends that you retain all receipts covering maintenance on your power equipment engine, but Honda cannot deny warranty coverage solely for the lack of receipts or for your failure to ensure that all scheduled maintenance has been completed.
  • Page 88 CONSUMER INFORMATION Warranty Coverage Honda power equipment engines sold in the United States and Canada are covered by this warranty for a period of two years from the date of delivery to the original retail purchaser or the length of the Honda Distributor’s Limited Warranty, whichever is longer.
  • Page 89 CONSUMER INFORMATION To Obtain Warranty Service You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during their normal business hours.
  • Page 90 CONSUMER INFORMATION Disclaimer of Consequential Damage and Limitation of Implied Warranties American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment;...
  • Page 91: Initial Use Instructions

    INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Open the oil maintenance cover. 3. Remove the oil filler cap. 4. Add enough SAE 10W-30 API service category SJ or later (or equivalent) oil to bring the oil level to the upper limit of the oil filler neck.
  • Page 92: Fuel

    INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage.
  • Page 93: Battery

    INITIAL USE INSTRUCTIONS Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under warranty. Move the generator at least 10 feet (3 meters) away from the fueling source and site before starting the engine.
  • Page 94: Before Operation

    INITIAL USE INSTRUCTIONS BEFORE OPERATION Before using the generator, all generator operators must read the following chapters and sections: • GENERATOR SAFETY (pages 6–9) • CONTROLS & FEATURES (pages 10–18) • BEFORE OPERATION (pages 19–20) • OPERATION (page 21) • STARTING THE ENGINE (pages 22–25) •...
  • Page 95: Index

    INDEX AC Applications .................. 28 AC Circuit Protectors ................15 AC OPERATION................... 27 AC PARALLEL OPERATION..............29 AC Parallel Operation Applications........... 31 AIR CLEANER SERVICE ..............47 Air Index ....................74 ARE YOU READY TO GET STARTED?..........19 BATTERY SERVICE ................56 BEFORE OPERATION..............
  • Page 96 INDEX Eco-Throttle Switch ................14 ECO-THROTTLE SYSTEM ..............36 Electric Shock Hazards ................. 7 Emission Control System Information..........71 Emission Control System Warranty..........84 Engine Cylinder................... 64 ENGINE LACKS POWER..............67 Engine Oil ..................64, 89 ENGINE OIL CHANGE................. 45 ENGINE OIL LEVEL CHECK ..............
  • Page 97 INDEX MAINTENANCE SAFETY..............40 MAINTENANCE SCHEDULE .............. 41 NO POWER AT THE AC RECEPTACLES..........68 NO POWER AT THE DC RECEPTACLE ..........68 Oil Alert Indicator................17 OPERATION..................21 Operator Responsibility ............... 6 Output Indicator.................. 16 Overload Alarm (Indicator) ..............16 Parallel Operation Outlets..............
  • Page 98 INDEX SAFE OPERATING PRECAUTIONS............ 21 SAFETY LABEL LOCATIONS..............9 SEDIMENT CUP CLEANING............... 54 Safety Precautions................40 Serial Number Location ..............69 SERVICING YOUR GENERATOR ............39 SPARK ARRESTER SERVICE.............. 51 SPARK PLUG SERVICE............... 49 Special Requirements ................ 38 Specifications..................75 STANDBY POWER ................
  • Page 99: Quick Reference Information

    QUICK REFERENCE INFORMATION Fuel Type Regular unleaded gasoline with an ethanol content of no more than 10% and a pump octane rating of 86 or higher Engine Oil Type SAE 10W-30, API SJ or later (or equivalent), for general use (page 46) Maximum oil capacity: 18 oz (0.55 L)
  • Page 100 英 31ZT7633 00X31-ZT7-6330 Printed in Japan...