Before installing this product make sure the structure you are fixing the product to can withstand 
its load and the total load of any other unit installed. 
 
1. Hang the unit to the structure and firmly tighten the clamp. 
2. Make sure there is enough distance between each unit to allow free movement 
3. Make sure there are no obstructions to the free movement of the yoke 
4. Fix the safety bond  
 
 
7. CONNECT TO THE POWER SUPPLY 
 
• Make sure the plug you are fitting withstands the lamp power load.  
• This fixture must be grounded 
• To perform a correct wiring, please note that the cores in this mains lead are colour‐coded as 
follows: 
In case the colours of the cores do not correspond to the colour of the connection points on your 
plug, please proceed as follows: 
• The green or green and yellow core must be connected to the connection point marked with 
the letter E or with the symbol   or coloured in green or in green‐yellow 
• The blue core must be connected to the connection point marked with the letter N or with the 
symbol  
or coloured in black 
• The brown core must be connected to the connection point marked with the letter L or with 
the symbol 
or coloured in red 
 
• Before you finally position this product for use, temporarily connect it to a properly fused 
power supply to check the lamp works correctly.  
• Protect each product with a fuse suitable to the lamp you are using. Should you connect this 
product to a dimmer pack, please make sure this is fitted with suitable protective fuses. 
 
 
8.  CLEANING AND MAINTENANCE 
 
To ensure maximum performance of the product, a regular maintenance service should be carried 
out. Please make sure the product is cold and disconnected from power supply when doing this. 
 
• clean all reflective parts such as reflector, mirror and lens opening the product, if 
necessary. 
• check the lamp and the lenses and replace any visibly damaged component. 
• clean air ducts and fans in order to allow proper ventilation activity on the product. 
• check internal and external wiring and replace any cable which should be damaged by heat 
or mechanical agents. 
 
 
Tel. +39 0376 771 777 – fax +39 0376 772 140 – email info@ldr.it – web www.ldr.it 
LDR Inno A1000 PO & Inno S1000 PO User's Manual – 1.0 
Ground: green+yellow  –  Neutral: blue  ‐  Live: brown 
Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy 
 