SICK MRS1000 Operating Instructions Manual

SICK MRS1000 Operating Instructions Manual

Peoplecounter

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
MRS1000 PeopleCounter
PeopleCounter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MRS1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK MRS1000

  • Page 1 O P E R A T I N G I N S T R U C T I O N S MRS1000 PeopleCounter PeopleCounter...
  • Page 2 Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 3: Table Of Contents

    Opening user interface................Overview....................User levels....................General settings..................PeCo settings.................... 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 4 12.1 Declarations of conformity and certificates..........12.2 Licenses....................O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 6: Safety Information

    O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 7: Limitation Of Liability

    Knowledge of the software and hardware environment for the ■ particular application 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 8: Operational Safety And Specific Hazards

    Install the grounding for the product and the system in accordance with national ■ and regional regulations. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 9: Product Description

    The type label gives information for identification of the device. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 10: Principle Of Operation

    This is carried out in 4 spread-out scan layers (scan layers 1 to 4) Figure 3: Scan layers O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 11: Person Counting Application

    Transmission to a third device is also possible. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 12 SOPASair or the digital inputs of the data supplier are not. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 13: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 14: Mounting

    Detection area: Typically 3.50 m x 2.10 m (W x H); max. 10.00 m x 2.10 m (W x H) O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter...
  • Page 15: Mounting The Device

    Switch on the supply voltage. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 16: Electrical Installation

    10 V applied to the device, max. power consumption as per type label): 6.5 m at 12 V; 46.5 m at 24 V; 66.5 m at 30 V. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 17: Prerequisites For Safe Operation Of The Device

    Closed current loop with equalizing currents via cable shield 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 18 Within the islands, a stable equipotential bonding prevents equalizing currents on the cable shields. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 19: Connection Diagram

    The recommended connecting cables and their associated technical data can be found online at: www.sick.com/people-counter 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 20 Digital output 2: Room capacity Brown warning threshold reached (traffic light: yellow) O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 21: Connection Options

    Figure 13: Connection example of stand-alone operation (single device) or host in host/guest operation, PNP outputs, active high inputs 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 22: Connecting The Device Electrically

    Connect the device according to the connection diagram, see "Connection dia‐ gram", page O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 23: Operation

    Password User/Authorizations Customers: Display only, no configu‐ ration 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 24: General Settings

    6 minutes when the counter is activated. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 25: Peco Settings

    100 %. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 26 (host) defined as a host. Enter the IP address of the host. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 27: Region Of Interest Settings

    If activated, the scan data is shown in 3D in the Scan view. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 28: Counter

    Additional information on the connection (Connection) and status (Mode) of the connected guests is displayed on the host. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 29: Room Capacity

    -1 if the value for Room capacity is set to 0 or the device is defined as the host. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 30: About

    {"args": {"roomCapacity": <new capacity>}} O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 31 You have to reload the web page to see the effect in the software interface of SOPASair. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 32: Service And Diagnostics: Operation With Sopas Et

    Following installation of the device description file, the device can be selected from the device catalog and added to a project. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 33: Communication In Sopas Et Via Sopas Commands

    This parameter outputs the total value of IN counted by the device and the position and size of the last counted IN. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 34 In these cases it works like an event, i.e. every time the device registers a new person, the SOPAS variable is triggered and the IN/OUT value is updated. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 35: Maintenance

    5600006). Rinse off coarse dirt first with water. The cleaning interval essentially depends on the ambient conditions. 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 36: Troubleshooting

    The device must be sent in the original packaging or an equivalent padded pack‐ aging. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 37: Disposal

    Separate the recyclable materials by type and place them in recycling containers. ■ 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 38: Technical Data

    100 mA per output E.g. 30 V*100 mA = 3 W O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 39: Dimensioned Drawing

    Close range (no detection or measurement possible) â Detection zone ã 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 40: Performance

    Max 90% air humidity (non-condensing) humidity Ambient light immunity 80 klx O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK Subject to change without notice...
  • Page 41: Accessories

    8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 42: Annex

    For license texts see www.sick.com/licensetexts. Printed copies of the license texts are also available on request. O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter 8025783/1GI8/2022-09-14 | SICK...
  • Page 43 ANNEX 8025783/1GI8/2022-09-14 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000 PeopleCounter Subject to change without notice...
  • Page 44 Phone +7 495 283 09 90 E-Mail info@sick.com E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG  |  Waldkirch  |  Germany  |  www.sick.com...

Table of Contents