Download Print this page

Magnescale LT80-NE Operating Manual

Display unit

Advertisement

Quick Links

Display Unit
LT80-NE
Read all the instructions in the manual carefully before use and strictly follow them.
Keep the manual for future references.
This manual corresponds to the software version Ver 1.05.00JP.
This manual describes only the added and changed functions compared to the software version
Ver 1.04.00, so be sure to also read the software version Ver 1.02.00/1.04.00 Operating Manual.
Operating Manual

Advertisement

loading

Summary of Contents for Magnescale LT80-NE

  • Page 1 Display Unit LT80-NE Read all the instructions in the manual carefully before use and strictly follow them. Keep the manual for future references. This manual corresponds to the software version Ver 1.05.00JP. This manual describes only the added and changed functions compared to the software version Ver 1.04.00, so be sure to also read the software version Ver 1.02.00/1.04.00 Operating Manual.
  • Page 2 ・Functions added by V1.05.00JP LT80-NE software version V1.05.00JP adds and changes the following functions compared to V1.04.00JP. 1. Display resolution setting ・・・・・・・・・・・・・・・・・・・・・P.2 ・The measurement value display resolution can be set in the view frame. Measurement values can be displayed at a resolution lower than the input resolution of the measuring unit.
  • Page 3 1. Display resolution setting This function sets the display resolution of the measurement values displayed in the view frame. A display resolution lower than the input resolution of the measuring unit can be set. ・View frame settings screen Display resolution setting Touch inside the frame to cycle through the available display resolution settings.
  • Page 4 2. Scaling This function sets the display magnification for the measurement display values. This enables operations such as compensation in account of the linear expansion of the object to be measured, x2 display, 1/2 display, and average value processing of two measuring units using calculations.
  • Page 5 3. Preset settings for frames with a calculation set Starting from this version, preset values can also be set for frames with a calculation set. ・View frame settings screen Touch inside the frame and use the numerical keypad to enter the preset value.
  • Page 6 4. Measurement data save An auto save function by number of data has been added, and the Data menu has been changed. The operation related contents are as follows. Setting contents: Import setup parameters from external memory Export setup parameters and measurement data to external memory Measurement data auto save setting Clear measurement data saved in display unit Device...
  • Page 7 • Import/Export data These buttons are used to import and export data from and to an external memory. Import: Imports setup parameters from an external memory to the display unit. Export: Exports setup parameters and measurement data from the display unit to an external memory.
  • Page 8 • Measurement data format settings and auto save settings The following date and time formats and Decimal points can be selected for the format when saving measurement data in an external memory. Save mode selects whether to export data to an external memory manually or automatically according to the number of measurement data.
  • Page 9 • Save mode The following selections are available. Manual : Export operation using the Data menu, or save operation using the display unit I/O No. of data : Set the number of data. The measurement data is automatically saved in the external memory when the set number of data is reached.
  • Page 10 • Addition of data save function set via the display unit I/O Save operation can be performed from the display unit I/O regardless of whether manual or auto (No. of data) is selected for Save mode. * Save operation can be performed before the set number of data in auto mode is reached, but note that measurement operation stops while save is in progress.
  • Page 11 5. Function change when using the MG80-LM In previous versions, measuring screen refresh was not performed while latch operation is stopped (standby status for operation, measurement start button text color is gray). From this version, however, normal operation is possible and the display is refreshed even while latch operation is stopped.
  • Page 12 Co., Ltd. et sont destinées exclusivement à l'usage des acquéreurs de l'équipement décrit dans ce manuel. Magnescale Co., Ltd. interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l'équipement à...
  • Page 13 Note: Th is product (or technology) may be restricted by the government in your country. Please make sure that end-use, end user and country of destination of this product do not violate your local government regulation. 45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan LT80-NE 2020.6 2-A02-969-1A Printed in Japan ©2020 Magnescale Co., Ltd.