EPI Valumass 400 Series Installation, Wiring & Configuration

Thermal mass flow meters

Advertisement

Quick Links

INSTRUCTION MANUAL
VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS
Title:
This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization.
Valumass™
Thermal Mass Flow Meters
400-440 & 500-540 Series
Installation, Wiring, and Dimensions
www.epiflow.com
Eldridge Products, Inc.
465 Reservation Road
Marina, CA 93933
Tel: 800-321-3569 or 831-648-7777
Fax: (831) 648-7780
Email:
Sales@epiflow.com
or
Service@epiflow.com
Page 1 of 29
Rev.: A
Document # 90000002
TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
PRINTED ON THIS DATE: 8/23/2021 AND TIME: 10:19:40 AM.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Valumass 400 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EPI Valumass 400 Series

  • Page 1 INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. Valumass™ Thermal Mass Flow Meters 400-440 & 500-540 Series Installation, Wiring, and Dimensions www.epiflow.com Eldridge Products, Inc.
  • Page 2: Table Of Contents

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. Applicable Models: Series 400-440 Series 500-540 Approvals CE Approved Instrument 400 & 440 Series Flow Transmitter: Manufacturer rated as Type 4X, IP66 500 &...
  • Page 3 INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 400 & 440 S ........................11 ERIES 500 & 540 S ........................12 ERIES AC T ........................13 RANSFORMER...
  • Page 4: Introduction, Power Requirements, And Signal Interface

    Ten feet of five-wire connection cable is provided with the standard remote assembly. If more cable is required, please inform your EPI sales representative at the time of order. The transmitter is independent of cable length and will not suffer any signal degradation with length changes.
  • Page 5: Signal Interface

    DC Voltage Coefficient Resistance Loop Examples: Input Ohms Max. *24 VDC Powered EPI Flowmeter Power Input Supply: 32.708 115/230 VAC Powered EPI Flowmeter Power Input Supply: 32.708 Isolated - Customer Powered 4-20 mA Current Loop: 34.167...
  • Page 6: General Installation And Guidelines

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. General Installation and Guidelines The Valumass™ thermal dispersion sensor must be exposed to the flowing gas within the process pipe at a location that provides a uniform and consistent flow profile across the pipe diameter.
  • Page 7: Straight Run Requirements

    General Guideline for Minimum Straight Run Requirements Note: 10x within the illustration represents 10 ID lengths and 15x represents 15 ID lengths and so forth. Some of EPI inline flow meters come with flow conditioning plates that can assist with shorter upstream conditions. Consult factory...
  • Page 8: Installation Of Inline Flow Meters

    The flow section is typically specified to match the user’s flow conduit and is plumbed directly in the flow line. Inline mounting styles are available through EPI for line sizes 1/4" pipe and larger. Consult our factory for flow section end mounting options.
  • Page 9: Installation Of Insertion Flow Meters

    The tube length will be determined by EPI based upon the installation specifications.
  • Page 10: Insertion Depth Guidelines

    *For other pipe sizes: please use the insertion depth with the nearest inside diameter associated with your process pipe, or contact the EPI Service department Final Equation: Depth + Fitting Height = Total Depth from top of fitting to probe end.
  • Page 11: Wiring Diagrams

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. Wiring Diagrams 400 & 440 Series Page 11 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 12: 500 & 540 Series

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 500 & 540 Series Page 12 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 13: Ac Transformer

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. AC Transformer Page 13 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT. PRINTED ON THIS DATE: 8/23/2021 AND TIME: 10:19:40 AM.
  • Page 14: Frequency Output (400 & 440 Series)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. Frequency Output (400 & 440 Series) Page 14 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 15: Frequency Output (500 & 540 Series)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. Frequency Output (500 & 540 Series) Page 15 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 16: Dimensional Diagrams

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. Dimensional Diagrams 400 Series (Integral) Page 16 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 17: 400 Series (Remote Electronics Or 115/230Vac)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 400 Series (Remote Electronics or 115/230VAC) Page 17 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 18: 440 Series (Integral)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 440 Series (Integral) Page 18 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 19: 440 Series (Remote Electronics Or 115/230Vac)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 440 Series (Remote Electronics or 115/230VAC) Page 19 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 20: 500 Series (Integral)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 500 Series (Integral) Page 20 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 21: 500 Series (Remote Electronics)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 500 Series (Remote Electronics) Page 21 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 22: 540 Series (Integral)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 540 Series (Integral) Page 22 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 23: 540 Series (Remote Electronics)

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. 540 Series (Remote Electronics) Page 23 of 29 Rev.: A Document # 90000002 TIME STAMP: THIS IS A CONTROLLED DOCUMENT AS LONG AS NO NEW RELEASED REVISION SUPERSEDES IT.
  • Page 24: Factory Calibration

    Flow calibration is a process of comparing or verifying the meter under strict test conditions against a meter of better accuracy used as a calibration standard. EPI flow calibrations are traceable to NIST through traceability of the instrumentation and equipment used.
  • Page 25: General Specifications And Information

    Or user specified STP at time of order NIST traceable calibration Standard *EPI is not responsible for measurement errors due to flow profile irregularities caused by installation, piping configurations, surface corrosion or scale, valve placement, etc. ** Specify overage process operating temperature, with high & low limits.
  • Page 26: 500 & 540 Series Specifications

    Or user specified STP at time of order NIST traceable calibration Standard *EPI is not responsible for measurement errors due to flow profile irregularities caused by installation, piping configurations, surface corrosion or scale, valve placement, etc. ** Specify overage process operating temperature, with high & low limits.
  • Page 27: Specification Notice

    EPI of the defect within the warranty period. Upon receipt of the defective product, EPI will either repair or replace the defective product at its sole option. EPI MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AS TO THE PRODUCTS. EPI MAKES NO WARRANTY THAT THE GOODS SOLD TO ANY PURCHASER ARE FIT FOR ANY PARTICULAR PURPOSE.
  • Page 28: Service Work

    Storage EPI recommends equipment and instrumentation be stored in an environmentally controlled storage shelter or warehouse when not in use. All openings should be sealed off to prevent foreign materials from entering the instrumentation.
  • Page 29: Eu Declaration Of Conformity

    INSTRUCTION MANUAL VALUMASS SERIES INSTALLATION, WIRING, AND DIMENSIONS Title: This document is the property of Eldridge Products Inc. and shall not be copied or used without written authorization. EU Declaration of Conformity This is to declare, in accordance with Directives 2014/34/EU, 97/23/EC, 2004/108/EC, 93/68/EEC, 92/31/EEC, 89/336/EEC, that the following products are designed and manufactured in accordance with the requirements of the directives.