INSTALLATION GUIDE
GVS-65 SIDE WALL VENT TERMINATION KIT
For Type BH, Class IIA (65°C) Gas Venting Systems
Combustion Air
Vent Base
2" Screws x 4
Vent Cap
1" Screws x 4
4. Use the vent base as a template to locate the vent and intake
holes and four mounting holes. Cut two 3-7/8" diameter holes
for the exhaust and intake pipes. Drill four 3⁄16" diameter
holes for the mounting screws. Attach vent base to wall with
4 - #8 x 2" SS Screws.
5. Assemble the vent cap to the vent base with 4 - #8 x 2" SS Screws.
6. Install the exhaust and intake piping through the wall into the
vent termination kit. Use RTV silicon sealant to seal the pipe to
the vent cap, to allow future disassembly and cleaning. DO NOT
use PVC solvent cement to seal this connection.
7. Seal gap between pipes and wall with expanding foam or other
suitable material.
8. Extend intake and exhaust pipes to appliance, make sure to
attach intake and exhaust to the correct sides of the vent cap.
Use only Westlake Pipe & Fittings GVS-65 pipe, fittings, primer,
and solvent cement.
9. Operate appliance and look for leaks for a minimum of 15
minutes to make sure that it works properly and that all piping
joints are sealed to prevent the escape of combustion products
into the home.
Certifications:
Rated for flue gas temperatures up to and including 65°C. This vent kit
is certified to ULC S636 as part of the Westlake Pipe & Fittings GVS-65
Gas Venting System, for use as a Type BH, Class IIA (65°C) gas venting
system. This vent kit is approved for use with certain appliances;
please check with your appliance manufacturer for more information.
www.westlakepipe.com
©2023 Westlake Pipe & Fittings All rights reserved PL-IG-021-CA-EN-0523.1
Vent
Minimum 12"
to overhang
Maintain 12" minimum clearance
above highest anticipated snow
level or grade whichever is greater
WARNING
Furnaces: This vent kit is to be used with gas appliances with flue gas temperatures up to
65°C. This vent termination kit must be approved for use with any appliance by the appliance
manufacturer. DO NOT use for Roof Top Venting. Use this kit for side wall venting only.
WARNING
To avoid bodily injury, fire or explosion, solvent cements MUST be kept away from all
ignition sources (i.e. sparks, open flames and excessive heat) as they are combustible
liquids. Avoid breathing cement vapors or contact with skin and/or eyes.
WARNING
High Voltage – Disconnect ALL electrical power and shut off gas supply before servicing
or installing. Multiple power sources may be present. Failure to do so may cause property
damage, personal injury or death.
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
What to do if you smell gas:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use and phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
WARNING
To avoid property damage, personal injury or death due to explosion or fire, install a gas detecting
warning device. Since the odorant in propane gas can be reduced by iron oxide (rust), a gas
detecting warning device is the only reliable method to detect propane gas leaks.
WARNING
Property damage, furnace malfunction, personal injury or death may result from improper
installation or maintenance performed by untrained personnel. Installation must conform with
local codes, with codes of the country having jurisdiction. Call your installing dealer or other
qualified service companies to perform the installation or maintenance inspection.
WARNING
To avoid the risk of property damage, personal injury or fire, shut off gas supply first, then
disconnect the electrical supply before proceeding with the kit installation.