When Web Control Administrator Rights Password Is Not Set (Non-Protect Mode) - Panasonic PT-VW330E Operating Instructions Manual

Hide thumbs Also See for PT-VW330E:
Table of Contents

Advertisement

Control commands via LAN (continued)

When WEB Control administrator rights password is not set (Non-protect mode)

Connection method
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and
make a request for connection to the projector.
Acquire the IP address from the menu screen of the projector, and the port number from the WEB control
page.
IP address :
Obtain from MAIN MENU → [Network] → [Network status]
Port No. :
Acquire from the WEB control "Detailed set up" → "Command port set up" page
2)
There is a response from the projector.
Response data
Data section
"NTCONTROL"
(ASCII string)
9 bytes
Mode : 0 = Non-protect mode
Command transmission method
Transmit by the following command format.
Transmitted data
'0'
0x30
1 byte
Receive data
'0'
0x30
1 byte
Receive data
"ERR1"
"ERR2"
"ERR3"
"ERR4"
"ERR5"
"ERRA"
24
Header
'0'
0x30
1 byte
Header
'0'
0x30
1 byte
Error message
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
4 bytes
Blank
Mode
' '
0x20
0x30
1 byte
1 byte
Data section
Control command
(ASCII string)
Undefined length
Data section
Control command
(ASCII string)
Undefined length
Termination symbol
'0'
Termination symbol
Termination symbol
Termination symbol
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-vw330uPt-vw330eaPt-vx400uPt-vx400ePt-vx400ea

Table of Contents