Knx bridge with ip interface and power supply knx + aux 640ma + mqtts (8 pages)
Summary of Contents for Eelectron IPSBA01KNX
Page 1
IPSBA01KNX Knx bridge with ip interface and power supply knx + aux 640ma + MQTT USER MANUAL Translation of the original instructions Version: 1.0 Date: 06/06/2023...
Page 2
IPSBA01KNX Index Introduction to the user manual ..............................4 Meaning of the symbols used ..............................4 Product overview ..................................4 Installation instructions ................................4 Configuration and commissioning ............................. 5 General parameters .................................. 5 General settings ..................................5 Surveillance configuration ............................... 6 Logics configuration ................................6 Network configuration ................................
Page 3
We therefore cannot accept any liability for this. Any necessary corrections will be incorporated into newer ver- sions of this manual. Eelectron S.p.A. Via Claudio Monteverdi 6, I-20025 Legnano (MI), Italia Tel +39 0331.500802 info@eelectron.com IPSBA01KNXFI00020100_UM_EN_1.0 M E M B E R...
This manual is intended for use by KNX installers and describes presence information is managed. The presence detection solu- functions and parameters of the IPSBA01KNX device and how tion can deduce the presence of people in the room using one or the settings and configurations can be changed using the ETS more dedicated sensors.
In large systems after a power outage or shutdown, this delay avoids ETS® program.
Page 6
IPSBA01KNX Bus controlled Warning time - seconds 20 ... 255 Initial enable state This parameter defines the warning time (seconds). This time indicates disabled / enabled how much before the end of the surveillance time a group value read is It defines the initial state of the IP interface function when bus con- sent on the bus through the “Warning Read Request” object. Used by...
Page 7
IPSBA01KNX “<General> Alarm 4 Bytes” This parameter enable the object “<General> Alarm 4 Bytes” which 4 Bytes sends to the BUS a bitmask containing the network errors. “<General> Alarm Text” 14 Bytes Alarm text disabled / enabled KNX PARAMETER SETTINGS This parameter enable the object “<General> Alarm Text” which sends a text string containing network errors to the BUS. DNS 1 address max 15 bytes With this parameter (Domain Name System) it’s possible to convert a web address in an IP address which uniquely identifies the device.
Need help?
Do you have a question about the IPSBA01KNX and is the answer not in the manual?
Questions and answers