Identify The Recording Interface Callback Settings; Device Door Control - Black Box BDS-8W Configuration Manual

Hide thumbs Also See for BDS-8W:
Table of Contents

Advertisement

CHAPTER 2: DYNAMIC DETECTION DISPLAY LAN INT. V1.4
Example:
{
"data": "2020-03-15 22:10:50", // Device current time
"result": 1,
"success": true
}

2.17 IDENTIFY THE RECORDING INTERFACE CALLBACK SETTINGS

Request method: POST request
Request address: http://device ip: 8080/setIdentifyCallback
FIELD
pass
callbackUrl
Request description:
The callback can be set in other settings of the APP terminal settings.
Example:
{
"data": "http://192.9.51.45:8080/setIdentifyCallback",
"result": 1, //1 Set successfully -1 No callbackUrl field -2 callbackUrl Field is empty
"success": true //true Set successfully, false set failed
}

2.18 DEVICE DOOR CONTROL

Request method: POST request
Request address: http://device ip: 8080/device/openDoorControl
FIELD
pass
20
REQUEST DATA
MODE
REQUEST
String
Y
String
Y
REQUEST DATA
MODE
REQUEST
String
Y
1.877.877.2269
DESCRIPTION
Device password
Identify the url interface for record upload
DESCRIPTION
Device password
BLACKBOX.COM