INDEX GENERAL INTRODUCTION ................3 GENERAL ..................3 SAFETY INSTRUCTIONS ..............3 OVERVIEW OF THE MAIN COMPONENTS ........4 USE OF THE PRODUCT ..............5 STICKERS ..................8 IDENTIFICATION OF THE PRODUCT ..........9 PRODUCT DATA ................10 IN CASE OF EMERGENCY ...............10 SAFETY PARTS AND WARNING SIGNS ..........11 UNPACKING, TRANSPORTATION AND STORAGE ......12 MAINTENANCE &...
OPERATING MANUAL – DataLift 250 INTRODUCTION Thank you for putting your trust in the Ixolift products. We design all our products to solve all your lifting challenges. Read the whole manual before using the machine. Store this manual in a safe and proper way for use in the future.
OPERATING MANUAL – DataLift 250 OVERVIEW OF THE MAIN COMPONENTS REMOTE CONTROL MAST DIRECTIONAL LOCK LEVER HANDLE BAR EMERGENCY STOP TABLE BATTERY INDICATOR FRONT WHEEL & LOCKING BOLT MAIN SWITCH BACK WHEELS CHARGE INLET BLOCK WHEEL USER MANUAL COMPARTMENT CABLE CHAIN...
OPERATING MANUAL – DataLift 250 USE OF THE PRODUCT GENERAL Only use on level surface and never go under the load. Always follow the safety instructions of this manual. IXODL250-021 LIFTING AND LOWERING The DataLift is switched on with the main switch (5). Please always switch off when the unit is not in use.
Page 6
OPERATING MANUAL – DataLift 250 50-002 BRAKE Do not step with your whole bodyweight on the brake. IXODL250-007 Max. Load 30kg. The brake is activated by pushing the brake lever (8) down. In horizontal position the brake is inactive. It is a directional and swivelling brake for the back tires.
Page 7
OPERATING MANUAL – DataLift 250 ACCESSORIES The platform is equipped with 4 holes M10 for fixing accessories. Read and understand the instructions of the accessories! On the bottom side of the platform there are holes for attaching hooks if needed.
OPERATING MANUAL – DataLift 250 STICKERS All safety stickers must be fixed to the DataLift for safe operation. IXODL250-017 IXODL250-011 IXODL250-018 IXODL250-016 IXODL250-020 IXODL250-020 IXODL250-010 IXODL250-019 IXODL250-010 IXODL250-006...
OPERATING MANUAL – DataLift 250 IDENTIFICATION MANUFACTURER KALKKIMÄENTIE 2 FI-03100 NUMMELA, FINLAND TYPE DataLift 250 SERIAL NO XXXXX YEAR 2022 195 kg (with Battery, MASS no Load) MAX LIFTING CAPACITY 250 kg PLATFORM HEIGHT LOWERED 138 mm RAISED 2.400 mm Battery: 2 x 12V each 10,2 kg ±5%...
OPERATING MANUAL – DataLift 250 PRODUCT DATA CHARACTERISTICS TYPE UNIT VALUE DIMENSIONS 1150x640x1700 LIFTING HEIGHT 2400 WEIGHT SYSTEM VOLTAGE WHEELS TYPE UNIT VALUE WHEEL MATERIAL POLYURETHANE FRONT WHEEL DIAMETER REAR WHEEL DIAMETER DRIVE TYPE UNIT VALUE ENGINE POWER WINCH LIFTING CAPACITY...
OPERATING MANUAL – DataLift 250 UNPACKING, TRANSPORTATION AND STORAGE FIXING & LIFTING POINTS The DataLift is fitted with 4 fixing points for transport and one lifting point. Only use correct screws and lifting tabs. Screws for fixing: Dimension M8, min. length 20 mm and class 8.8...
Page 13
OPERATING MANUAL – DataLift 250 UNPACKING The DataLift is delivered on a euro pallet and fixed with 4xM8 hexagon screws. There are two ramps supplied for unloading. Only use attached ramps! Wrench size: 13mm for fixing screws. Wood screw bit: TX20...
OPERATING MANUAL – DataLift 250 MAINTENANCE OPENING OF THE BACK COVER Park the DataLift safely, lock the position with the brake (8) and switch off the main switch (5). Loosen the 4 screws on the back cover, remove the back cover.
OPERATING MANUAL – DataLift 250 DAILY OPERATIONAL INSPECTION AND MAINTENANCE Check the DataLift daily before use, paying particular attention to the wheels and cable. Foreign objects such as cloths, etc. can block the wheels, table, mast or cable. After finishing working with the DataLift and before checking, unload the table and lower it to the lowest position.
OPERATING MANUAL – DataLift 250 BATTERY The DataLift is equipped with maintenance-free AGM lead battery 2 x 12 V/36Ah. These batteries are maintenance-free and must not be refilled with water. Note: Please observe the maximum operating temperature of the battery.
Page 17
OPERATING MANUAL – DataLift 250 Fuse charger Fuse main circuit Batteries FUSE The DataLift is equipped with 2 fuses, one for the charger and one for the main circuit. If the fuse is blown, make sure to identify the cause and repair!
OPERATING MANUAL – DataLift 250 TROUBLESHOOTING Problem Reason Solution Fuse is out Replace fuse Main switch Enable main switch Remote cable broken Replace remote control No response Pull emergency reset button Emergency stop to reset Winch motor is broken Replace motor...
OPERATING MANUAL – DataLift 250 SPARE PARTS According to Spare parts list. Only use qualified original spare parts! WARRANTY The warranty of one year from date of invoice covers materials, manufacturing or construction defects. Damages, which are due to natural wear and tear, improper handling or unauthorized modification are not covered by the warranty.
03.2022 Authorized Representative Johan Friis TECHNICAL FILE REFERENCE IXOLIFT-DL250-Y1 DECLARATION Ixolift declares that the equipment described herein is in conformity with Supply of Machinery (Safety) Regulations 2008: Harmonised standards used: EN ISO 3691-5:2020 EN ISO 12100:2011 Ixolift declares that the equipment described herein is in...
Page 21
Ixolift declares that the equipment described herein is in conformity with Machinery Directive 2006/42/EC. Harmonised standards used: EN ISO 3691-5:2020 EN ISO12100:2011 Ixolift declares that the equipment described herein is in conformity with Electromagnetic Directive 2014/30/EU: Harmonised standards used: EN 61000-6-2:2019 EN 61000-6-3:2007+A1:2011.
Need help?
Do you have a question about the DataLift 250 and is the answer not in the manual?