How To Setup The Unlock Parameter In Monitor - PROEM CDC-2F B Series User Manual

Table of Contents

Advertisement

Available languages

Available languages

connect one lock
Take off the Jumper
S1
BUS
PL
+
POWER
SUPPLY

5.5 How to setup the unlock parameter in Monitor

monitor
intercom
setup
exit
1.Press MENU button twice
to enter the MAIN MENU
page,then press setup item.
Unlock Time
1
Unlock Mode
0
Exit
6.Use
/
to select the
item, use
/
to change
the value of the item.select Exit
item,press MENU button to save
the settings automatically.
Note:
1.must connect DT599 correctly before setting.
2.the parameter will be saved in DT599 automatically,so you need only set on one monitor.
S2
S-
+
LOCK
Outdoor Tone
-- 01
Intercom Tone
-- 05
Monitor Time
-- 1min
Advanced Set...
Auto Record
-- OFF
Exit
2.Select Advanced Set...item
and press MENU button to
enter,a password will be
asked.
Hardware ver
0302
Software ver
0168
Voltage
22.4V
Manufacture
00.0T
Restore to default
Exit
5.Press UNLOCK button
and hold for 2s.
connect two locks
Take off the Jumper
S1
S2
BUS
PL
S-
+
+
POWER
SUPPLY
Password:
0
3 . T h e d e f a u l t p a s s w o r d i s
2008. press
/
change the value,Press
button to select the location,after
finishing,press MENU button to
enter next step.
Slave Addr Set
Guard Unit Set
Date/Time Set...
Other Settings...
Information...
Exit
4.Select Information...item
and press MENU button to
enter next page.
LOCK
* * *
button to
/
-- 0
-- 0
-
9
-