CDC-2FxB
English
Talk LED Indicator:
off
Unlock LED Indicator:
VHFRQG ORFN LW ZLOO EH ÀDVKHG WZR WLPHV
Lock Control Jumper:
Doorstation Code DIP:
Main Connect Port:
‡ BUS: Connect to the bus line, no polarity.
‡ PL: External lock power input, connect to the power positive(power +).
‡ S1+, S2+: Lock power(+) output, to connect 2 locks.
‡ S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
Lock Power supply:
Power Consumtion:
NO, COM dry contact:
Unlocking time:
Working temperature:
4.1 How to open the unit
-
4
-
'XULQJ WDONLQJ WKH /(' ZLOO EH WXUQHG RQDIWHU ¿QLVKLQJ WDONLQJ LW ZLOO EH WXUQHG
When release the first lock,it will be flashed one time.when release the
To select the lock type: see 5.2.1 , 5.2.2
Total 4 doorstations can be supported,see 6.1
To connect the bus line and the electronic locks.
3. Specifications
4. Mounting and Settings
slide down
12Vdc, 300mA(Internal Power)
1W in standby, 12W in working
Max. 48V dc 1.5A
1 to 9 seconds, set by Monitor
-10ºC ~ 45ºC
take off the bracket