10) Indoor unit fan control for energy saving (Only cooling mode)
Enable or disable indoor unit fan control when the outdoor unit is stopped.
Setting Description
No
Yes
*If setting value is "00":
When the outdoor unit is stopped, the indoor unit fan operates following the setting on the remote controller
continuously.
*If setting value is "01":
When the outdoor unit is stopped, the indoor unit fan operates at very low speed intermittently.
( . . .Factory setting)
Function Number
Setting Value
49
- (01 - 42) -
00
01