Wiring Diagrams - Carrier EVOLUTION 189BNV Service Manual

V variable speed heat pump, v variable speed air conditioner with puron refrigerant
Table of Contents

Advertisement

WIRING DIAGRAMS - - 189BNV
W
BLK
YEL
CHOKE
4
1
2
+
LD1
DC
DC FAN
F L1 L2
FUSE 3 AMP
120
60
30
30
60
90
J2
FORCED
DEFROST
YEL
BLK
PL18
LVCH
GRN
TB
21
23
L2
L1
208/230 1Ø POWER SUPPLY
Fig. 44 – 189BNV WIRING DIAGRAM - - Sizes 13 and 24B
CONNECTION DIAGRAM
OFM
COMP
(R)
U
V
(C)
W
RED
U
(S)
V
YEL
RED
BLK
CHOKE
RED
BLK
YEL
-
DC
U
W
V
MOTOR & COMPRESSOR
CONTROL SECTION
HPS
BLU
BLU
MOTOR CONTROL COMM HEADER
HP CONTROL COMM HEADER
RVS
PEV
PL10
1
SW2
BLU BLU
1 2
PL19
STATUS COMM
SPT
1
PEV
PL17
AIR CONDITIONER
OST
CONTROL SECTION
1
PL16
ODT
MODEL
1
PL15
24V
UTIL
C
R
1
Y
2
W
O
Y
OCT
OAT
1
BLK
BRN
BRN
BLK
UTILITY INTERFACE
CHOKE
OCT
OAT
EQUIP GND
Fig. 45 – 189BNV WIRING DIAGRAM - - Sizes 25, 36, 37, 48, 49, 60
UNIT OPERATION
This control board contains a 3.5 minute short cycle protector. A 3.5 minute delay will occur between
Compressor off/on cycles. To bypass delay, short forced defrost pins for 1 second then release.
However, there is an additional 2.5 minutes delay upon expiration of the 3.5 minute short cycle delay to
ensure the high and low side pressures are equalized. This is important for long term rotary compressor
reliability. It is a delay that cannot and must not be bypassed. The internal crankcase heater is energized
during off cycle as needed.
NOTES:
1. To Be Wired In Accordance With National Electric Code (N.E.C.) And Local Codes.
HPS
2. Use Copper Conductors Only. Use Conductors Suitable For At Least 75ºC (167ºF).
3. Two Wire A and B Required For Communication. If Outdoor Unit Improperly
BLU/PNK
BLU/PNK
Grounded, Connect Indoor Ground To "C" Terminal.
4. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or
Equivalent Wire.
5. Check All Electrical Connections Inside Control Box For Tightness.
6. Do Not Attempt To Operate Unit Until Service Valves Have Been Opened.
7. If Communicating, Must Use With Infinity or Evolution User Interface Listed In
Pre-sale Literature Only.
8. For Non-Communicating Thermostats, 24VAC To Be Provided To R Connection.
9. N.E.C. class 2, 24 V circuit, min. 40 VA required, 60 VA on units installed with LLS.
-LEGEND-
SPT
FACTORY POWER WIRING
BLK
+
FIELD POWER WIRING
WHT
-
FACTORY CONTROL WIRING
RED
FIELD CONTROL WIRING
COMPONENT CONNECTION
BLK
JUNCTION
BLK
FIELD SPLICE
OST
PLUG CONNECTION
BLK
SYSTEM COMMUNICATION
COMM
COMPRESSOR
COMP
BLK
HIGH VOLTAGE INDICATOR LED
LD1
ODT
HIGH PRESSURE SWITCH
HPS
LOW VOLTAGE CHOKE HARNESS
LVCH
* MAY BE FACTORY OR FIELD INSTALLED
MODEL PLUG CHART
MODEL MODEL
PIN RESISTANCE (K
PLUG
SIZE
HK70EZ
1 - 4 (R1)
2 - 3 (R2)
25
011
5.1K
150K
36
012
5.1K
180K
025
11K
091K
37
48
013
5.1K
220K
11K
49
027
150K
5.1K
60
014
270K
37
MODEL
MODEL PLUG
OAT
OUTDOOR AIR THERMISTOR
OCT
OUTDOOR COIL THERMISTOR
ODT
OUTDOOR DISCHARGE THERMISTOR
OFM
OUTDOOR FAN MOTOR
OST
OUTDOOR SUCTION THERMISTOR
PEV
PRESSURE EQUALIZER VALVE
SPT
SUCTION PRESSURE
TRANSDUCER
STATUS
SYSTEM FUNCTION LIGHT
SW2
DEFROST TIME SELECT
TB
TERMINAL BLOCK
UTIL
UTILITY CURTAILMENT
24V
24 VOLTS DC
)
340613-101 REV. C