2. intrOduCtiOn
Powerful dehumidification capacity. removes excess moisture from air, preventing build-up of mildew and mould. features auto-defrost function,
which activates if the room temperature falls too low. Washable activated carbon air filter. Refrigerant is environmentally friendly R410A, SDH50.V2
uses r410A. may be connected to a drain hose for continuous operation. mounted on castors for manoeuvrability.
3. speCifiCatiOn
model no:
Supply Voltage:
Power:
dehumidifying capacity:
Working Space:
Maximum Airflow
refrigerant:
condensate tank:
Working Temperature Range:
Dimensions (L x W x H)
Weight:
4. OperatiOn
efficiency of the dehumidifier is influenced by the air outside the room. for operating
efficiency, try to avoid opening and closing the windows and doors. for best performance,
operate the dehumidifier within the usable operating temperature.
4.1.
OperatiOn
4.1.1.
Plug the unit in to the mains socket, a beep will be heard when inserting the plug.
4.1.2.
Press the "ON/OFF" switch and the operation light will illuminate, the humidity display
will light to display the previous set humidity. The initial setting for humidity is 60%, after
3 seconds the display will show the current humidity.
4.1.3.
Press the humidity up or down buttons to adjust to the desired humidity required.
If the required humidity is 3% below the current humidity the unit will start automatically,
if the set humidity is 3% more than the current humidity the dehumidifier will automatically
stop.
4.1.4.
the unit has a memory function. use the humidity up and down buttons to adjust to the
desired setting and then press the memory button to record the setting, each time the
machine is switched on it will automatically run at the required setting.
4.1.5.
When setting the humidity to less than 30%, the unit will run continuously and the
display will read "co".
4.1.6.
To shut the dehumidifier down press the "ON/OFF" switch.
note: if the humidity setting is greater than the current humidity the unit will not run.
WarninG! the fan motor and compressor must run for at least 3 minutes while
dehumidifying.
dO nOt start the dehumidifier immediately after shutting down, allow 3 minutes
8
before restarting.
fig.2
© Jack sealey limited
sdH30
230V
750W
30ltr/day
30 - 40mtr³
3
300m
/hr
Contains fluorinated greenhouse gases.
this product is hermetically sealed.
R410a (HFC32:23% HFC125:25%) 0.330kg
GWP:2088
co
Equivalent: 0.689t
2
5ltr (with auto shut-off)
5 - 32°C
497 x 420 x 850mm
28kg
Control panel
Original Language Version
SDH50
230V
900W
50ltr/day
50 - 70mtr³
3
350m
/hr
Contains fluorinated greenhouse gases.
this product is hermetically sealed.
R410a (HFC32:50% HFC125:50%) 0.330kg
GWP:2088
co
Equivalent: 0.689t
2
5ltr (with auto shut-off)
5 ~ 32°C
497 x 420 x 850mm
30kg
fig.1
sDH30, SDH50.V2 Issue 2 14/03/18