Hose
Connector
Hose
(White)
Connector
Connector
WILL NOT CIRCULATE WATER
Is the impeller of the drain pump clogged?
Are the Hose Connector and/or Hose clogged?
Is the connector disconnected, disassembled?
Is the coil of the right side of drain pump open
or short circuited? (Coil R is 18-30Ω )
When checking voltage between the
connectors during spin, is the voltage 120V AC,
as the figure?
NO
NO
NO
NO
30
YES
Remove foreign material.
YES
Remove foreign material.
Reconnect or repair
YES
the connector.
YES
YES
Replace PUMP MOTOR
ASSEMBLY.
NO
Replace the MAIN PWB
ASSEMBLY.

Advertisement