9.1.2 Adjustment Procedure
All adjustments except "Touch Panel Calibration"and "Factory Setting" performs using "14 Adjustment function for the service" in
service mode menu.
"Touch Panel Calibration" is performed using 16 of service mode menu and "Factory Setting" is performed using 1, of service
mode menu. Refer to "6 Service mode" and "10 Factory Setting".
[Execute adjustment function for service]
1. Set the power switch to ON.
2. Press the "O.I.S./ USER 3"button, "WHITE BAL"button and "Zoom Lever"to W side for more than 3 seconds until
the top screen of the Service Mode Menu is displayed.
3. Touch the [
] once then touch the [14] of LCD.
4. Touch the [YES] of LCD.
- 96 -