Installation
Gas Connection

GAS HOSE RESTRAINT

If the oven is mounted on casters, a commercial flexible
connector with a minimum of 3/4" (1.9 cm) inside diam-
eter must be used along with a quick connect device.
The restraint, supplied with the oven, must be used to limit
the movement of the unit so that no strain is placed upon
the flexible connector. With the restraint fully stretched the
connector should be easy to install and quick connect.
The restraint (ie: heavy gauge cable) should be 1,000 lb.
(453 kg) test load and should be attached without damag-
ing the building. DO NOT use the gas piping or electrical
conduit for the attachment of the permanent end of the
restraint! Use anchor bolts in concrete or cement block.
On wooden walls, drive hi test wood lag screws into the
studs of the wall.
1. Mount the supplied bracket to the leg bolt just below
the gas inlet.
2. The clip on restraining cable can be attached to the
mounting bracket.
Back of Oven
Restraint
Cable Bracket
Double stacked unit shown. Use the same procedure for single
units with 25" (64 cm) legs.
Figure 7
WARNING!!
If the restraint is disconnected for any reason
it must be reconnected when the oven is re-
turned to its original position.
U.S. and Canadian installations
The connector must comply with the Standard for Con-
nectors for Movable Gas Appliances, ANSI Z21.69 or
Connectors For Moveable Gas Appliances CAN/CGA-
6.16 and a quick disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas
Fuel, ANSI Z21.41 or Quick Disconnect For Use With Gas
Fuel CAN 1-6.9. Adequate means must be provided to
limit the movement of the appliance without depending
on the connection and the quick disconnect device or its
associated piping. Adequate means must be provided to
limit the movement of the appliance without depending
on the connection and the quick disconnect device or its
associated piping.
General export installations
The restraint and quick connect must conform with Local
and National installation standards. Local installation
codes and/or requirements may vary. If you have any
questions regarding the proper installation and/or opera-
tion of your Blodgett oven, please contact your local
distributor. If you do not have a local distributor, please
call the Blodgett Oven Company at 0011-802-658-6600.