Advertisement

Quick Links

CML1 / CDL1
CML1 / CDL1
Original Operating Instructions
Original Operating Instructions
CML1 / CDL1
CML1 / CDL1

Advertisement

Table of Contents
loading

Summary of Contents for Captron CML1

  • Page 1 CML1 / CDL1 CML1 / CDL1 Original Operating Instructions Original Operating Instructions CML1 / CDL1 CML1 / CDL1...
  • Page 2: Safety General Safety

    This manual has been written for technicians/installers and operators and should be kept for future reference. Read these operating instructions carefully and make sure that you have fully understood the contents before installing or working with the CML1 / CDL1. Safety General safety...
  • Page 3 DANGER Danger designates a hazardous situation, which, if ignored, will lead to death or serious injury. The symbol next to the warning indicates the type and source of the danger. WARNING Warning designates a hazardous situation, which, if ignored, may lead to death or serious injury. The symbol next to the warning indicates the type and source of the danger.
  • Page 4 NOTICE Notice designates a situation, which may cause material damages and impair the product’s function if attention is not paid. Tip provides additional useful information about the handling of the product. Symbol Meaning Avoiding and adverting danger in the warning note ►...
  • Page 5: Personnel Qualifications

    WARNING Improper work on electrical systems! Electric shock can result in death or life-threatening injuries. Before working on electrical systems, disconnect them from their voltage supply and secure them against being switched on again. Work on electrical installations should be carried out only by qualified personnel in compliance with local and national electrical regulations and specifications.
  • Page 6: Intended Use

    Intended use The indicator light is intended for use in accordance with the items listed here, the values from the “Technical specifications” chapter and the product description. Only connect the product to a limited energy source as per IEC 61010 or to an NEC class 2 power supply unit. Source current <...
  • Page 7: Technical Specifications

    Technical specifications Operating voltage 24 V (21.6 ...26.4 V) Reverse polarity protection Protection of all cables/lines (temporary) Power consumption CDL1 Max. 20 mA at 24 V CTL1 Max. 30 mA at 24 V Operating temperature -20...+50°C Degree of protection IP Front IP69K Relative air humidity Max.
  • Page 8: Dimensional Drawing

    Dimensional drawing Example representation plug, M8 4-pin CML-1_9 / CDL1-1_9...
  • Page 9 CML1-1_8 / CDL1-1_8 CML1-6_8 / CDL1-6_8...
  • Page 10 CML1-1_8_/CPM20 CDL1-1_8_/CPM20 Drilling pattern Drilling pattern...
  • Page 11 Connection CML1-_7_... 200 mm single strands with wire end ferrules Wire end ferrules with plastic collars DIN 46228 Wire cross-section strands 0.15 mm CML1-_5_... CML1-_K_... Plug M8, 4-pin Terminal strip, 5-pin...
  • Page 12 ► Insert the indicator light into the prepared hole and screw the lock nuts (B) back ► Position the indicator light (A) and tighten the lock nuts with max. 1 Nm. Connect CML1 Different colors are shown depending on CML1 actuation.
  • Page 13 Pin assignment Indicator light color 24 V 24 V Green 24 V Blue 24 V 24 V Yellow* 24 V 24 V Violet 24 V 24 V Light blue 24 V 24 V 24 V White* Colors not technically pure...
  • Page 14 black +VDC / LED 3 LED3 white +VDC / LED 2 LED2 brown +VDC / LED 1 LED1 blue Connect CDL1 Different colors are shown depending on CDL1 actuation.
  • Page 15: Maintenance

    black +VDC / LED 2 LED2 white +VDC / LED 1 LED1 blue Maintenance Carry out the following maintenance operations at the specified intervals. Operation as needed annually Clean the switch surface Check cable for integrity...
  • Page 16 Operation as needed annually Check screw connection for tightness NOTICE Solvents contained in cleaning agents can attack the plastic of the button! Clean the surface of the button with a neutral cleaning agent or a damp microfiber cloth. Disassembly ► Disconnect the system from its voltage supply and secure it against being switched on again.
  • Page 17: Manual Updates

    Manual updates CAPTRON reserves the right to make changes to the contents of this manual as needed. The most current version can be found on our website. www.captron.com . Or scan the QR code.
  • Page 18 Imprint The operating instructions have been authored and published by CAPTRON Electronic GmbH Johann-G.-Gutenberg-Straße 7 82140 Olching – Germany Tel.: +49 (0)8142 - 44 88 - 160 sales@captron.com www.captron.com Copyright 2020 CML1 - CDL1 1.1...
  • Page 19: Product Description

    Product description...

This manual is also suitable for:

Cdl1

Table of Contents