Salvislab Thermocenter TC40 User Manual
Hide thumbs Also See for Thermocenter TC40:

Advertisement

Thermocenter TC40 / TC100
User Manual
- 1 -
Copyright © Salvis Lab / Edition 191107

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Thermocenter TC40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Salvislab Thermocenter TC40

  • Page 1 Thermocenter TC40 / TC100 User Manual - 1 - Copyright © Salvis Lab / Edition 191107...
  • Page 2: Table Of Contents

    User Manual Thermocenter TC40 / TC100 DECLARATION OF CONFORMITY ........................4 IMPORTANT INFORMATION..........................5 ........................5 UICK NFORMATION FOR ERVICE TECHNICAL DATA SHEET..........................6 ’ .........................6 ECHNICAL S FROM THE OVENS INTRODUCTION ..............................7 ................................7 VERVIEW ..............................7 PPLICATIONS ..............................7 ONTROLLER ..............................7 OOR ALARM ................................8 AFETY GETTING STARTED............................9...
  • Page 3 APPENDIX D ..............................34 TC 40........................34 RAWING HERMOCENTER APPENDIX E ..............................35 TC 100......................... 35 RAWING HERMOCENTER APPENDIX F ..............................36 ..........................36 RAWING PARE ARTS APPENDIX G..............................37 ..........................37 PARE UMBERS Copyright© SalvisLab / Edition 191107 - 3 -...
  • Page 4: Declaration Of Conformity

    (Name/Unterschrift oder Kennzeichnung des Befugten) (Place and date of issue) (name and signature or equivalent marking of authorised person) (Lieu et date) (nom et signature du signataire autorisé) Rotkreuz, 12.02.2002 Marcel Käppeli Technical Manager - 4 - Copyright © SalvisLab / Edition 191107...
  • Page 5: Important Information

    Please fill out all necessary information for your Thermocenter. It helps you when you contact your Dealer or Service department. SERIAL NUMBER: PHONE NUMBER SERVICE PURCHASE DATE SOFTWARE VERSION (See Display at Power ON) Notes: Copyright© SalvisLab / Edition 191107 - 5 -...
  • Page 6: Technical Data Sheet

    10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times without prior notice. - 6 - Copyright © SalvisLab / Edition 191107...
  • Page 7: Introduction

    Introduction Overview The THERMOCENTER TC40 / TC100 is an oven with a patented design. All functional elements are integrated in the door. Forced Air with an intelligent control of fan-speed in a range between 0-100%. of ramping functions. Fast and accurate heating up procedure. More applications available to users Microprocessor-controller with enhanced Fuzzy-Logic - Allows precise ramping of temperature as well as an excellent reproduction of temperature distribution in the chamber.
  • Page 8: Safety

    There is also an additional mechanical over-temperature device which shuts down the oven High quality accurate PT 100 temperature sensors. Superior “Swiss Made” manufacturing quality according ISO9001 - 8 - Copyright © SalvisLab / Edition 191107...
  • Page 9: Getting Started

    Display shows current Firmware Version see Power On Sequence To start oven or program it see Chapter Operating Menus Cleaning To clean the System use mild detergents. No Acid or similar detergents should be used. Copyright© SalvisLab / Edition 191107 - 9 -...
  • Page 10: Your System Components

    Your System Components Air Exhaust Air Flap Air Inlet Door Handle Controller RS232 Connector Shelf Glider Shelf Fan Outlet Spring loaded door lock Door Switch to indicate a open door (alarm switch) - 10 - Copyright © SalvisLab / Edition 191107...
  • Page 11: Controller

    ON/OFF Switch ON or OFF your System. When on LED is lit LED Indicators When lit: Heat Power is on When lit: You are running a program When flashing: A delayed start for program operation was entered. Copyright© SalvisLab / Edition 191107 - 11 -...
  • Page 12: Operating

    If you are using a start date or time you will be able to set a future date/time to start the system with pre- setted parameters i.e. temperature, Gradient, Fan Speed, Timer - 12 - Copyright © SalvisLab / Edition 191107...
  • Page 13: Main Menu Overview

    Configuration ESC returns to 4 Service Mode This menu point is protected by an access-code and is available Main Menu only for trained Service-Technicians. Press to select Service Mode ESC returns to Copyright© SalvisLab / Edition 191107 - 13 -...
  • Page 14: Main Menu Temp & Options

    +/- Change value confirms and saves the value Fan_Speed ESC restores the old value or returns to ____________100% Note: The minimal Fan Speed is depending on the system and is factory set. - 14 - Copyright © SalvisLab / Edition 191107...
  • Page 15 If your Start Date and/or Start Time is in the future you will see the operating display ESC restores the old value and skips back one input field HH) or goes back to Note: The pre-set time is the actual time from the real-time clock. Copyright© SalvisLab / Edition 191107 - 15 -...
  • Page 16: Main Menu Program

    Menu. _Delete ESC return to 2.5 Menu Program - Print Print a program Menu_Program____ to select [Print Program] 2.5.1 to scroll through the Menu. _Print ESC return to - 16 - Copyright © SalvisLab / Edition 191107...
  • Page 17: Menu Program Start

    If your Start Date and/or Start Time is in the future you will see the operating display ESC restores the old value and skips back one input field HH) or goes back to Note: The pre-set time is the actual time from the real-time clock. Copyright© SalvisLab / Edition 191107 - 17 -...
  • Page 18: Menu Program New

    +/- change desired value Fan_Speed confirm value 2.2.6 ESC restores the old value or returns to 04/01_______100% Note: The minimal Fan Speed is depending on the system and is factory set. - 18 - Copyright © SalvisLab / Edition 191107...
  • Page 19 +/- change desired value Fan_Speed confirm the value 2.2.11 ESC restores the old value or if in step 2 and higher returns to 04/02______ 100% 2.2.6 but the actual step will not be saved ! Copyright© SalvisLab / Edition 191107 - 19 -...
  • Page 20 If No selected: 2.2.11 2.2.13 Confirming & Saving the new program Program______P04 Displays confirmation that the new program has been stored. After a few seconds the display will return to Stored..._______ - 20 - Copyright © SalvisLab / Edition 191107...
  • Page 21: Menu Program Edit

    +/- change desired value. Pre-set value is the last used value in Set_Temperature_ manual mode. confirms and saves the value 2.3.7 04/02____110.0°C ESC restores the old value or returns to Note: Display 04/01 means actual program/step number. Copyright© SalvisLab / Edition 191107 - 21 -...
  • Page 22 If Yes selected: 2.3.12 Yes__ If No selected: 2.3.10 2.3.12 Save program display Program______P04 Displays confirmation that the new program has been stored. After a few seconds the display will return to Stored..._______ - 22 - Copyright © SalvisLab / Edition 191107...
  • Page 23: Menu Program Delete

    2.5.2 Displaying print in progress Program______P04 Display confirms that the program has been printed. After a few seconds it will return to Printing..._ __ For an example of printout and printer connection refer section Printer Operation Copyright© SalvisLab / Edition 191107 - 23 -...
  • Page 24: Main Menu Configuration

    +/- change value HHMM_______00:01 accept value and skips to the next input field ((HH MM) or saves the time and goes to ESC restores the old value and/or skips back one input-field - 24 - Copyright © SalvisLab / Edition 191107...
  • Page 25: Menu Service Mode

    The Display confirms that the Configuration has been Stored. After a few seconds it will return to Stored... 4 Menu Service Mode Main_Menu This menu point is protected by a code and is only available for trained Service-Technicians. _Service_Mode Copyright© SalvisLab / Edition 191107 - 25 -...
  • Page 26: Operating Displays

    15:00 Here you can see the actual Date and Time. This is the last Date 05.05.07 information of the Operating Display. Press the button to see Time 14:18 first display again - 26 - Copyright © SalvisLab / Edition 191107...
  • Page 27: Status Display: Program Mode Delayed Program Start

    If No selected: Back to running status 9.2 Conformation of cancelling a process Process stopped Display confirms that the running process has been cancelled. After a few seconds it will return to Main Menu Copyright© SalvisLab / Edition 191107 - 27 -...
  • Page 28: Messages And Errors

    Error: Safety Controller was active. Call Service Safety Bond Error: Temperature exceeded security range level. Cool down oven. If error persist call Service Temp out of rang Unexpected Call Service Error - 28 - Copyright © SalvisLab / Edition 191107...
  • Page 29: Printer Operation

    10.04.07, 09:35 Gradient 1,5 °C/Min Hold Time: 0:45 HHH:MM Set Temperature: 130,5 °C Fan Speed 80 % Act Temperature: 130.5 °C Gradient 1,5 °C/Min Hold Time: 1:00 HHH:MM Fan Speed 94 % Copyright© SalvisLab / Edition 191107 - 29 -...
  • Page 30: Temperature Limiter And Safety Controller

    5. Control Range of the Safety Controller 6. Actual Temperature Range of gradient 1. The gradient can be set in this range 2. This range can not be used. It is system depending - 30 - Copyright © SalvisLab / Edition 191107...
  • Page 31: Graphical Presentation Of A Program

    Step 1 : Start of program Step 2 : New parameter setting where used. Step 3 : New parameter setting where used. After finishing the step 3, the program ends. Copyright© SalvisLab / Edition 191107 - 31 -...
  • Page 32: Menu Structure Fields

    End of Program 2.3.7 2.3.6 2.3.8 Program stored.. Delete Program 2.4.1 2.4.1 Select Program 2.4.2 Delete Program 2.4.2 2.4.3 2.4.1 Program Deleted Print Program 2.5.1 2.5.1 Select Program 2.5.2 2.5.2 Program Printing - 32 - Copyright © SalvisLab / Edition 191107...
  • Page 33: Schematic / Wiring Diagram

    X10 = Leer / E mpty X11 = Speisung Heizung / Power heating element X12 = Leer / E mpty X13 = Anschluss Display / Connector Display X1 1 X1 0 R R W MADE BY RENGGLI Copyright© SalvisLab / Edition 191107 - 33 -...
  • Page 34: Drawing Thermocenter Tc 40

    Appendix D Drawing Thermocenter TC 40 - 34 - Copyright © Salvis Lab / Edition 191107...
  • Page 35: Drawing Thermocenter Tc 100

    Appendix E Drawing Thermocenter TC 100 4 5 0 4 6 0 5 7 0 5 7 0 6 6 0 Copyright© SalvisLab / Edition 191107 - 35 -...
  • Page 36: Drawing Spare Parts

    Appendix F Drawing Spare Parts 2 1 /2 2 1 6 /1 7 1 2 /1 3 2 6 /2 7 2 4 /2 5 3 /4 9 /1 0 - 36 - Copyright © SalvisLab / Edition 191107...
  • Page 37: Spare Part Numbers

    Appendix G Spare Part Numbers Position Part. Nr. Description 31W04141005 Panel TC-40/100 31W04144152 Display / Touch Panel 115V/230V 31W04144150 Main PCB 230V / 10A 31W04144151 Main PCB 115V / 10A 31W04142002 Air Inlet Protection Cover 31W04144014 Door Handle 31W04144013 Cable Relieve 31W04144018 Exhaust Knob 31W04140003...

This manual is also suitable for:

Thermocenter tc100

Table of Contents

Save PDF