Salvislab Thermocenter TC40 User Manual

Salvislab Thermocenter TC40 User Manual

Drying oven
Hide thumbs Also See for Thermocenter TC40:
Table of Contents

Advertisement

Salvislab Thermocenter TC40/100
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Thermocenter TC40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Salvislab Thermocenter TC40

  • Page 1 Salvislab Thermocenter TC40/100 User Manual...
  • Page 2: Table Of Contents

    Salvislab Thermocenter TC40/100 User Manual User Manual Salvislab Thermocenter TC40/100 CE DECLARATON OF CONFORMITY ....................5 GENERAL ..........................6 ....................... 6 URPOSE OF THIS DOCUMENT ........................... 6 ESCRIPTION ..........................6 OPYRIGHT ....................6 RESENTATION OF SAFETY ADVICE SAFETY .............................6 ......................6 BSERVE SAFETY ADVICE ......................
  • Page 3 Keyboard input ......................51 USB ............................. 52 14.1 USB-S ................... 52 XPORT MPORT WITH TICK ETHERNET .......................... 52 ADMIN FEATURES ......................53 16.1 SW U ........................53 PDATE 16.1.1 Unlock options ......................54 16.2 ........................54 EST SCREEN Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 4 RAWING SPARE PARTS APPENDIX I ..........................65 TC100 ......................65 RAWING SPARE PARTS APPENDIX J ..........................66 TC40/100 ....................66 RAWING SPARE PARTS PANEL APPENDIX K ..........................67 ....................... 67 PARE PARTS AND OPTIONALS GLOSSARY ........................... 69 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 5: Ce Declaraton Of Conformity

    (Name/Unterschrift oder Kennzeichnung des Befugten) (Place and date of issue) (name and signature or equivalent marking of authorised person) (Lieu et date) (nom et signature du signataire autorisé) Alain Frenguelli Rotkreuz · CH, 31.10.2015 Alain Frenguelli Technical Manager Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 6: General

    1.3 Copyright The copyright of this composition and all documents entrusted to the customer remains at all time with Renggli AG/Salvislab. This document must not be provided to third parties or made available without the written permission of Renggli AG.
  • Page 7: Important Information

    3.1 Quick Informations for Service Dear customer, Thank you for purchasing our Salvislab Thermocenter drying oven. Please fill out all the necessary information of your Thermocenter in the form below and keep it ready in case you will need to contact for assistance your Dealer or Service department.
  • Page 8: Technical Data

    All indications are average values, typical for units produced in series. Differing ambient temperatures or variances in the design of individual equipment may produce different performance. We reserve the right to alter technical specifications at all times without prior notice. *We reserve the right to alter technical specifications at any time without prior notice. Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 9: Introduction

    Salvislab Thermocenter TC40/100 User Manual Introduction 5.1 Overview The THERMOCENTER TC40/100 is an oven with a patented design • Robust “SwissTEQ” quality design • Thermocenter ovens ensure effective drying without damaging the material being dried • All functional elements are integrated in the door •...
  • Page 10: Regulation

    Acoustic alarms for key tones, program end and errors • Acoustic alarm for door open with adjustable delay (default 30s) • User administration (user ID) protected by password • Dynamic IP address • Counter for operating hours - optional • - 10 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 11: Multi User Levels

    A mechanical over-temperature device provides additional safety After power cut-off controller restarts automatically and last stored values remain in memory • High quality accurate PT100 temperature probes • Integrated door switch interrupts heater when opening the door • - 11 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 12: Getting Started

    Close the door • Switch power on • Display shows Salvislab logo during boot • The device is ready for use when the SalvisTEQ Home menu appears on screen • For information on how to operate and navigate properly through the GUI, refer to chapters 9-16 •...
  • Page 13: System Components

    Air inlet Door handle Air flap Air exhaust Shelf support Shelf Fan outlet Spring loaded door lock Door switch Rating plate Thermocenter front view - closed door Thermocenter front view - open door - 13 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 14: Operation

    Duration a set temperature has to be hold (build-in timer is starting to count back as soon as set • temperature is reached) Maximal set time is 999 hours and 59 minutes • Start date / time Future date/time to start process or program • - 14 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 15: Salvisteq Graphic User Interface: First Steps

    Program mode is described in chapter 11. User level Logged on users Date and time display Open menu 9.2 Menu Pressing the tool button [4] opens the device menu. Program mode (11) Manual mode (10) Settings (12) - 15 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 16: Manual Mode

    Salvislab Thermocenter TC40/100 User Manual 10 Manual mode Temperature settings (10.1) Device-specific settings (10.2) Time settings (10.3) Play button, starts the warming process using the selected settings. - 16 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 17: Temperature Settings

    Select the type of heating curve. Linear heating using the set gradients Exponential heating, the target temperature is approached with the largest possible gradient. Target temperature Gradient (for linear heating processes only) Confirm input - 17 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 18: Device-Specific Setting Options

    Fan rotation speed. The fan speed can be set between 60 - 100%. Confirm input The fan is always required to ensure even internal heating. The speed can therefore be reduced, but the fan cannot be turned off completely. - 18 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 19: Time Settings

    Heat up and hold for specified time (10.3.3) Time settings, dependent on selected mode Confirm input 10.3.1 Start in Start of the heating process is delayed by the set time. A time of 000:00 indicates an immediate start. - 19 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 20: Start At

    10.3.3 Hold for Hold the target temperature for a specific length of time. The hold time begins once the target temperature has been reached. Time for which the target temperature should be held. - 20 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 21: Program Mode

    Existing programs can be modified once they have been loaded (11.5). 11.1 Create new program To create a new program you first need to enter a name for it. The name you enter cannot be changed later. Back to main screen Confirm input - 21 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 22: Program List

    Edit / create program (11.5) Menu 11.2 Program list This screen contains a list of all existing programs on the device. Back Program list Save program as (11.2.2) Load program from device (11.2.1) - 22 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 23: Load Program From Device

    "Load from USB" from the menu. 11.4 Program options An overview of the program is displayed once it has been loaded. Several actions are available. Program name Start Terminate (11.6) Edit (11.5) Export (11.7) Delete (11.8) - 23 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 24: Edit Program

    Temperature / general step settings (11.5.2) Fan settings (10.2.1) Previous program step Insert new program step before current step (11.5.1) Delete program step Next program step Insert new program step after current step (11.5.1) Finish editing - 24 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 25: Create New Program Step

    The set temperature will be reached as quickly as Fast possible Linear The set temperature is approached linearly The current temperature is held for a set period of Hold time Repeat The program jumps to a selected program step - 25 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 26: Temperature / General Step Settings

    Programs can also be set to be regularly repeated. Only one individual program can be scheduled. Back Program name Repetition type Daily (11.6.1) Weekly (11.6.2) Never (no repetition) Confirm input - 26 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 27: Daily Repetition

    Salvislab Thermocenter TC40/100 User Manual If a specific time is set for the program to run then the scheduler is automatically started. Execution time display Cancel scheduler 11.6.1 Daily repetition Execution time Confirm input - 27 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 28: Weekly Repetition

    Salvislab Thermocenter TC40/100 User Manual 11.6.2 Weekly repetition Execution time Selected weekday (11.6.2.1) Confirm input 11.6.2.1 Select day The corresponding buttons are used to the select the desired days for the program to be started. - 28 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 29: Export Program

    The selected program can be exported to a USB stick. A program can only be exported after a USB stick has been inserted into the device. Back Export target Export You are informed via an information bar after the program has been successfully exported or if an error occurred during the export process. - 29 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 30: Delete Program

    Salvislab Thermocenter TC40/100 User Manual 11.8 Delete program The loaded program can be deleted from the device. This action must then be confirmed. Back Confirm deletion - 30 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 31: Settings

    Salvislab Thermocenter TC40/100 User Manual 12 Settings Information (12.1) Language (12.2) Users (12.3) General settings (12.6) Logging (12.7) - 31 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 32: Information

    The info screen also contains a QR code that can be scanned to directly access the manufacturer's website. Back Device type Serial number RU serial number DU serial number Control unit software version Regulator firmware version Manufacturer address QR code, contains link to manufacturer´s website - 32 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 33: Language

    Salvislab Thermocenter TC40/100 User Manual 12.2 Language The user can select the interface language by pressing on the flag for the desired language. The language setting is applied after pressing the OK button. - 33 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 34: Users

    The user level is indicated using stars: User Calibrator Administrator Service technician Back Username User level Log out Create new user (12.3.1) Delete user (12.3.2) Confirm input - 34 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 35: Create User

    Salvislab Thermocenter TC40/100 User Manual 12.3.1 Create user Back Enter username Enter password Select role Confirm input 12.3.2 Delete user Back User list (select a user by clicking) Delete selected user Back - 35 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 36: Lock The Screen

    A small lock now appears on the display. The screen can now be locked by using your finger to drag the lock into the circle that appears on screen. User is logged on Start heating process Open lock appears Drag lock Circle appears Drag lock into circle, the oven is now locked - 36 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 37: Unlock Screen

    A screensaver appears after 30 minutes of standby time. This screen will only be activated, if no regulation is in progress. Touch the display on any position to deactivate the screensaver and return to the last screen. - 37 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 38: General Settings

    The internal and external temperature sensors can be calibrated with the help of this menu. Calibration is secured using a password or can be done only by the service technician. For more detailed information, please contact the manufacturer. - 38 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 39: Date And Time

    Salvislab Thermocenter TC40/100 User Manual 12.6.3 Date and time Back Set date Set time Confirm input 12.6.3.1 Set date Back Select date Confirm input - 39 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 40: System Log

    You can swipe up and down to scroll through the system log. Back List of log files Open log Export log Delete log Back - 40 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 41: Temperature Unit

    When regulating using the external sensor, the oven temperature is monitored with this value. Errors may occur if the limit is too narrowly set. The limits do not define the precision of the regulator. They define only when the safety regulator is activated. - 41 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 42: Reset

    The user can run a software update from here. The new software first needs to be loaded onto a USB stick. This is then inserted into the device. For further detail please refer to chapter 16.1. - 42 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 43: Network Settings

    IP address by the network. This can be manually set using "static" mode. 12.6.11.1 Automatic Back Mode (change by clicking) Current address (assigned by the network) Current subnet mask (assign by the network) Confirm input - 43 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 44 It can take a little time for the IP address to be assigned, as the controller must first check whether the set address is already in use on the network before setting the new address. - 44 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 45: Buzzer Delay

    Successful sterilization is recorded with the date and time in the oven in order to show that the last successful sterilization was run. 12.6.14 Product information This menu option brings up the oven settings. 12.6.14.1 Oven data Back Oven type Maximum temperature (operational) Minimum temperature (operational) Maximum temperature (calibration) Scroll Back - 45 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 46: Maximum Temperature

    12.6.16 Process log time This allows you to set the interval for logging process data. The value can be set between 2s and 5min. Longer sample times allow process data to be recorded over longer periods. - 46 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 47: System Error

    Acknowledge the marked error List of appeared errors Scroll If you acknowledge an error who is gone, it will be automatically deleted from the list. If the error condition is still met, the error will reappear. - 47 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 48: Dac

    Only available with the corresponding option. 12.7 Logs Users have the option to export or delete logged process data. Back List of process logs Delete selected process data Export selected process data Back - 48 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 49: Keyboard

    The keyboard can be switched between text (QWERTZ) and number input. 13.1 QWERTZ Back Switch to numeric keyboard Delete last character Confirm input 13.2 Numeric Back Delete last character Switch to QWERTZ keyboard Confirm input - 49 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 50: Special Input Errors

    Increase the respective digit Clicking on a number opens up the keyboard input (13.3.2) Lower the respective digit Name of the value to set Decimal point, position varies depending on value/value range Unit Confirm input - 50 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 51: Keyboard Input

    [1], [2], [0], [0]. Back Name of the value to set Delete last digit Confirm input If an invalid value is entered, then the user is prompted to enter a valid value. - 51 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 52: Usb

    The current status of the device can be called up over the Ethernet interface. A TCP/IP connection with the following properties is created for this: Port: 1234 IP address of the device More detailed information can be found in document [Host Interface Specification]. - 52 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 53: Admin Features

    An update may take several minutes. The controller will restart during the update. Please ensure to follow all instructions on the screen and never turn off the device. Only remove the USB stick once the update has completed and the device has restarted. - 53 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 54: Unlock Options

    Only remove the USB stick once the update has completed and the device has restarted. 16.2 Test screen The test screen allows all features and sensors of the device to be checked. - 54 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 55: Graphs Of Temperature Limits, Gradient And Program Run

    Thermal levels of a Thermocenter unit. Typ. value Color ID Param. Description [°C] Mechanical temperature limiter Electronical temperature limiter ≤200 Set point temperature Electronical over-temperature protection +10] WW, max Electronical under-temperature protection -10 ; T WW, min - 55 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 56: Range Of Allowable Heating Gradients

    This example shows a custom user program defined in the custom programs section with 4 steps and a pre- set calendar start date/time. For further detail please refer to chapter 11 “Program mode”. - 56 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 57 The program steps 1-4 contain respectively: Positive gradient (adjustable) Hold time (adjustable) Positive gradient (adjustable) Hold time (adjustable) Positive gradient (adjustable) Hold time (adjustable) Negative gradient (given) Hold time (according to program step 2) - 57 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 58: Wiring Diagram Tc40/100

    Potential free contact Door switch Analog output PT100 temperature probe Redundant PT100 temperature probe External connector Standard device wiring up - - - - - - Optional device wiring up Wiring diagram Salvislab Thermocenter TC40/100 - 58 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 59: Salvisteq Ru Printed Board

    Potential free contact Connection for main switch Connection for heating, fan Power stage heater Power stage fan Voltage converter Hardware controller/microprocessor RU Printed board - 2D layout RU Printed board - 3D view - 59 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 60: Salvisteq Du Printed Board

    Power supply Battery 3V 225 mAh SD card slot Display connection Power supply USB Port Ethernet Port USB extension LAN extension DU Printed board - 2D Layout DU Printed board - 3D view - 60 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 61: Legend

    Hardware controller/microprocessor DU Main Description Standard Optional outputs Connection to regulation unit Power supply Battery 3V 225 mAh SD card slot Display connection Power supply USB Port Ethernet Port USB extension LAN extension - 61 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 62: Drawing Salvislab Thermocenter Tc40

    Salvislab Thermocenter TC40/100 User Manual Appendix F Drawing Salvislab Thermocenter TC40 * Renggli AG / SalvisLab reserves the right to change technical specifications and dimensions without prior notice. - 62 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 63: Drawing Salvislab Thermocenter Tc100

    Salvislab Thermocenter TC40/100 User Manual Appendix G Drawing Salvislab Thermocenter TC100 * Renggli AG / SalvisLab reserves the right to change technical specifications and dimensions without prior notice. - 63 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 64: Drawing Spare Parts Tc40

    Salvislab Thermocenter TC40/100 User Manual Appendix H Drawing spare parts TC40 - 64 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 65: Drawing Spare Parts Tc100

    Salvislab Thermocenter TC40/100 User Manual Appendix I Drawing spare parts TC100 - 65 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 66: Drawing Spare Parts Panel Tc40/100

    Salvislab Thermocenter TC40/100 User Manual Appendix J Drawing spare parts panel TC40/100 - 66 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 67: Spare Parts And Optionals

    Heating element 230V 31W04143107 Air ventilation plate TC40 31W04143108 Air ventilation plate TC100 31W04943203 Door gasket TC40 1.5m 31W04943203 Door gasket TC100 2.0m 31W04144184 Display SalvisTEQ 31W04141006 Panel TC40/100 31W04144183 PCB DU SalvisTEQ - 67 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 68 Internal memory upgrade up to 32 GB (micro SD) Calibration certificate for one desired temperature 31F04715 and point (1 certificate) Additional calibration certificate for one desired 31F04716 temperature and point (2 to 10 certificate) 31F04750 IQ/OQ draft paper, 3 hard copies - 68 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 69: Glossary

    Mechanical temperature limit °C Standard room temperature °C Set point Temperature °C Electronical temperature limit °C ≤200 Electronical over-temperature limit °C +10] WW, max Electronical under-temperature limit °C -10 ; T WW, min - 69 Copyright© SalvisLab / Edition 30062016_2.0...
  • Page 70 Renggli AG / Salvislab Industrie-Ost CH-6343 Rotkreuz Switzerland T +41 (0)41 798 14 14 F +41 (0)41 798 14 40 www.salvislab.com salvislab@renggli.com...