Advertisement

Quick Links

Infosystem
Copyright © 2003~2015
Infosystem Technology Corporation, Ltd.
2F, No. 57, Lane 53, Dongnan St.
Hsinchu, Taiwan 300, R.O.C.
TEL: +886-3-562-7187
FAX: +886-3-561-1435
Service E-mail: services@infosystem.com.tw
Web page URL:http://www.infosystem.com.tw
E
E
®
I
O
-
D
-
I
O
-
D
-
Ethernet Digital I/O
Ethernet
Ethernet
Ethernet
User Manual
User Manual
User Manual
User Manual
Version 1.0
Version 1.0
Version 1.0
Version 1.0
Infosystem Technology Corporation, Ltd.
Infosystem Technology Corporation, Ltd.
Infosystem Technology Corporation, Ltd.
Infosystem Technology Corporation, Ltd.
2
1
0
M
2
1
0
M
Digital I/O
Digital I/O
Digital I/O
L
L

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EIO-D-210ML and is the answer not in the manual?

Questions and answers

Summary of Contents for Infosystem Technology Corporation EIO-D-210ML

  • Page 1 Digital I/O Infosystem ® User Manual User Manual User Manual User Manual Copyright © 2003~2015 Infosystem Technology Corporation, Ltd. Version 1.0 Version 1.0 Version 1.0 Version 1.0 2F, No. 57, Lane 53, Dongnan St. Hsinchu, Taiwan 300, R.O.C. TEL: +886-3-562-7187 FAX: +886-3-561-1435 Service E-mail: services@infosystem.com.tw...
  • Page 2 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem B. Uninstall ......................... 29. Index Step 1: Execute Uninstall Program ............. 20. 1. Index ............................ 1. Step 2: Click “Yes” to process ............... 30.
  • Page 3: Warranty

    Infosystem Technology Corporation, Ltd. Copyright © 2003 - 2005 Infosystem Technology Corporation, Ltd. All rights reserved. Printed in Taiwan.
  • Page 4: Product Information

    Photo Coupler Isolated Inputs commands in console mode. With no doubt, Photo Coupler Isolated Outputs EIO-D-210ML will bring you the best integration in Input / Output your applications. DC 24V Input x 12...
  • Page 5: Front Panel

    EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Exterior Exterior B. Front Panel A. Overview a. Connector 1 (CONN1) Serial Serial Digital Digital Port Port b. Ethernet 10/100MBaseT RJ45 Connector...
  • Page 6: Basic Specifications

    EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Specifications Specifications A. Basic Specifications B. Digital Input Specifications Entry Description Entry Description Communication Interface Ethernet 10/100M BaseT, RJ-45 Number of Input Points...
  • Page 7: Digital Output Specifications

    EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Specifications Specifications D. LED Indicator and Switch Description C. Digital Output Specifications – Box View – Entry Description Number of Input Points...
  • Page 8 D. LED Indicator and Switch Description E. Wiring – Description – Users may refer to the following diagram to connect the external wiring for the EIO-D-210ML module. LED Indicator: Front Panel PIN Definition – Description The SYS LED blinks at a rate of 1.5Hz and indicating normal work.
  • Page 9 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Specifications Specifications E. Wiring E. Wiring – Equivalent Input Circuit – – Equivalent Output Circuit –...
  • Page 10 F. ModBus Holding Register Definition – Input Address – The discrete I/O points of the EIO-D-210ML can easily be controlled and monitored through Modbus protocol. The Modbus address mapping with The 10-points digital input of EIO-D-210ML is mapped with the Modbus discrete I/O is described as the followings.
  • Page 11 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Software Installation Software Installation A. Installation A. Installation Step 1: Insert the CD and click the button Step 2: Click the Link of the Page The Software Installation CD that came with EIO-A-200 will automatically be run after inserting it into the CD-ROM drive.
  • Page 12 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Software Installation Software Installation A. Installation A. Installation Step 3: Press Next to Continue Step 4: Decide the Application Directory Figure3. Installation Welcome Message Figure4.
  • Page 13 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Software Installation Software Installation A. Installation A. Installation Step 5: Create the Directory if not existent Step 6: Create Program’s Shortcut Figure5. Create Application Directory...
  • Page 14 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Software Installation Software Installation A. Installation A. Installation Step 7: Decide if Desktop icon needed Step 8: Press Install to start installation Figure7.
  • Page 15 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Software Installation Software Installation A. Installation A. Installation Step 9: Process Installations Step 10: Finish Installation Figure9. Installing Figure10. Installation Finished...
  • Page 16 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Software Installation Software Installation B. Uninstall B. Uninstall Step 1: Execute Uninstall Program Step 2: Click “Yes” to process Uninstall Program is located at the application directory named “Uninstall Ethernet Converter Setup”.
  • Page 17 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Configuration Configuration A. By Browser A. By Browser Step 1: Ready to login. Step 2: Configure your parameters.
  • Page 18 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Configuration Configuration A. By Browser B. By Setup Tools Step 3: Finish and reboot. Step 1: Searching the devices. Step 2: Double click the selected item.
  • Page 19 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Configuration Configuration B. By Setup Tools C. By Direct Broadcast Commands Step 3: It needs broadcasting to handle all the configurations and it allows users to code their Configure and update your parameters.
  • Page 20 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Configuration Configuration C. By Direct Broadcast Commands C. By Direct Broadcast Commands User Level: For General Users User Level: For General Users...
  • Page 21 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Application Notes Application Notes A. Description: B. Disable Firewall of Windows XP SP2. Firewall will make the program off normal, so Step 2: Close the Firewall one might choose the following solutions to Choose “Close”...
  • Page 22 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Application Notes Application Notes C. Make Program exception for Firewall C. Make Program exception for Firewall Step 1: Choose "Exception" Step 2: Add on New Program and Selection Choose “Exception”...
  • Page 23 EIO-D_210ML EIO-D-210ML Digital Ethernet I/O Module Digital Ethernet I/O Module ® ® (Preliminary Version) (Preliminary Version) Infosystem Infosystem Application Notes Application Notes C. Make Program exception for Firewall C. Make Program exception for Firewall Step 3: Allow "Accept Any Computer"...

Table of Contents