Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Warranty All products manufactured by Infosystem are warranted against defective materials for a period of one year from the date of delivery to the original purchaser.
Page 6
ARP, ICMP, TCP, UDP, IP, DHCP-Client and even HTTP protocols. You can use any browsers to set the parameters, or just use the commands in console mode. With no doubt, EIO-A-200 will bring you the best integration in your applications.
Page 7
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Product Information B. Features Easy Configuration Setting Use Setup Tools to Configure the Settings Use HTTP, IE/Netscape Browser for Setting Good Security Concerned...
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Product Information C. Applications Data collection and Security Terminals Access Control Terminals Security Devices Time Recorders Warehouse Terminals Shop floor automation Terminals...
Page 9
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Exterior A. Overview RJ-45 Ethernet Port Analog Input Indicator Discrete Output DC 24V Power Input Dip Switch Discrete Output Analog Input...
Page 10
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Exterior B. Front Panel a. Connector 1 (CONN1) b. 10 BASE-T Ethernet c. Discrete Output LED Indication d. LED Indicator e. Connector 2 (CONN2) C.
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications A. Basic Specifications – Part 1 – Entry Description 10BaseT, RJ-45 Network Interface ARP, ICMP, TCP, UDP, IP, DHCP Client, HTTP,...
Page 12
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications A. Basic Specifications – Part 2 – Entry Description 0.5A/pt Max. load current 0.1mA or less Leakage current at OFF circuit 1.5V or less...
Page 13
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications B. LED Indicator and Switch Description – Top View – CONN1 Ethernet TOP View LINK CONN2...
Page 14
Switch Description: Defining Operation Range Users may set the positions of the dip switches which are located on the bottom side of the module to choose one of the operation ranges provided by the EIO-A-200 module. EIO-A-200 OPERATION RANGE Voltage inputs: 0~10V...
Page 15
(Preliminary Version) (Preliminary Version) Specifications C. Wiring Users may refer to the following diagram to connect the external wiring for the EIO-A-200 module. (Wires for analog input signals are recommended to have the shielding protection) – Analog Input Channels– CH1+...
Page 16
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications C. Wiring – DC 0.5A Digital Output x 2 (DO1, DO2) –...
Page 17
Specifications D. ModBus Holding Register Definition The EIO-A-200 module provides 11 registers (words) for users to access the status of the module and read the data from the input channels or write the data to the output register. These 11 registers are called scan data registers.
Page 18
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition Digital output register: (40001) Bit 1: DO1 output status Bit 2: DO2 output status Bit 3 to Bit 16 are reserved.
Page 19
Specifications D. ModBus Holding Register Definition Besides the scan data registers, the EIO-A-200 module also provides other Modbus holding registers for users to fill in the high/low limit value and define the conversion data type. High- and low-limit values will be used by the module for comparing the channel’s input signal to detect if the input signal is...
Page 20
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition Holding Register Description 40013 Flags for control A/D conversion 40014 High/low limit control flags 40015 Low limitation value of CH1...
Page 21
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition Holding Register Description Conversion data type 40032 (row data or engineering data) 40033 Low engineering setting value of CH1...
Page 22
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition Conversion control/speed flags: (40013) 1. Bit 1 to Bit 8 are reserved. 2. Bit 9 to Bit 16 are A/D conversion control flags.
Page 23
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition High/low limit control flags: (40014) Bit 1: low limitation control bit for CH1 Bit 2: high limitation control bit for CH1...
Page 24
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition Remarks: 1. If some bits of the high/low limit control flags are set to ‘1’, the input Signals of corresponding channels will be compared with the corresponding limitation values which were stored in the specified holding registers.
Page 25
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Specifications D. ModBus Holding Register Definition Remark: 1. The default status of the above bits is ‘0’. In other words, the default conversion data type for each channel is raw data.
Page 26
A. Installation Step 1: Insert the CD and click the button The Software Installation CD that came with EIO-A-200 will automatically be run after inserting it into the CD-ROM drive. Click the “Ethernet converter Setup Utilities” button will bring the installation page out, Figure1.
Page 27
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Software Installation A. Installation Step 2: Click the Link of the Page Click the Link of the Page to run the Ethernet Converter Setup Tools Installation Software.
Page 28
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Software Installation A. Installation Step 3: Press Next to Continue Figure3. Installation Welcome Message...
Page 29
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Software Installation A. Installation Step 4: Decide the Application Directory Figure4. Decide the Application Directory...
Page 30
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Software Installation A. Installation Step 5: Create the Directory if not existent Figure5. Create Application Directory...
Page 36
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Software Installation B. Uninstall Step 1: Execute Uninstall Program Uninstall Program is located at the application directory named “Uninstall Ethernet Converter Setup”. Execution of it could let the Ethernet Converter Setup Tools clearly be removed.
Page 37
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Software Installation B. Uninstall Step 2: Click “Yes” to process Figure12. Process Uninstall Step 3: Finished Figure12. Process Uninstall...
Page 38
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration A. By Browser Step 1: Ready to login.
Page 39
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration A. By Browser Step 2: Configure your parameters.
Page 40
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration A. By Browser Step 3: Finish and reboot.
Page 41
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration B. By Setup Tools Step 1: Searching the devices. Step 2: Double click the selected item.
Page 42
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration B. By Setup Tools Step 3: Configure and update your parameters.
Page 43
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration C. By Direct Broadcast Commands It needs broadcasting to handle all the configurations and it allows users to code their own application software.
Page 44
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration C. By Direct Broadcast Commands User Level: For General Users Admin Level: For Factory Default Setting – Command List B – User Level –...
Page 45
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Configuration C. By Direct Broadcast Commands User Level: For General Users Admin Level: For Factory Default Setting – Command List C – Admin Level –...
Page 46
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Application Notes A. Description: Firewall will make the program off normal, so one might choose the following solutions to Firewall program, “Disable” or “Exception”.
Page 47
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Application Notes B. Disable Firewall of Windows XP SP2. Step 2: Close the Firewall Choose “Close” to close firewall.
Page 48
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Application Notes C. Make Program exception for Firewall Step 1: Choose "Exception" Choose “Exception” in Firewall Program. And add on new program of Setup Tools.
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Application Notes C. Make Program exception for Firewall Step 2: Add on New Program and Selection Choose “Setup Tools” to make it as an...
Page 50
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Application Notes C. Make Program exception for Firewall Step 3: Allow "Accept Any Computer" Allow “Accept Any Computer” to finish exception.
Page 51
Ethernet Analog I/O Controller Ethernet Analog I/O Controller EIO-A-200 EIO-A-200 ® ® Infosystem Infosystem (Preliminary Version) (Preliminary Version) Application Notes C. Make Program exception for Firewall Step 4: Finished Finish Exception.
Need help?
Do you have a question about the EIO-A-200 and is the answer not in the manual?
Questions and answers