Environmental
Working Conditions
Ambient temperature: -5°C ~+40°C;
RH: 5% ~95%;
Max. altitude: 2000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless
and ventilated conditions, the full load temperature rise not exceeding 40°C.
Storage Conditions
Ambient temperature: -40°C ~+70°C;
RH:0% ~95%;
Max. altitude: 20000 meter.
Reliability
No.
Item
01
MTBF
02
Anti-vibration
Safety
Insulation Characteristics
Input to output
Insulation
Input to case
resistant
Output to case
Input to output
Hi-Pot
Input to case
Output to case
Description
Average operating life > 30000h
5mm/50Hz/600s vibration test
DC500V 50MQmin (25°C, Humidity^70%)
DC500V 50MQmin (25°C, Humidity^70%)
DC500V 50MQmin (25°C, Humidity^70%)
1500Vac 50Hz 1 minute <10mA
1500Vac 50Hz 1 minute <10mA
500Vac 50Hz 1 minute <10mA
-4-
Remark
25 °C
PASS