SICK RFU65 Series Operating Instructions Manual
SICK RFU65 Series Operating Instructions Manual

SICK RFU65 Series Operating Instructions Manual

Rfid read/write device (uhf)
Table of Contents

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
RFU65x
RFID read/write device (UHF)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RFU65 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK RFU65 Series

  • Page 1 O P E R A T I N G I N S T R U C T I O N S RFU65x RFID read/write device (UHF)
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Wiring digital inputs ................. 6.10 Wiring digital outputs ................8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 4 Maintenance..................69 Maintenance plan..................Cleaning..................... Troubleshooting................. 70 10.1 Overview of Potential Errors and Faults..........10.2 Detailed fault analysis................10.3 Status log....................10.4 SICK service....................10.5 Repairs...................... 10.6 Returns...................... 10.7 Replacing the device................Decommissioning................74 11.1 Disposal..................... Technical data..................75 12.1 Features....................
  • Page 5: About This Document

    14. The type designation of your device can be found on the type label. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 6: Explanation Of Symbols

    The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 7: Further Information

    Further information More information can be found on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 8: Safety Information

    • RFU65x operating instructions SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 9 RFU65x operating instructions as well as the declarations of conformity and certificates on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 10: Improper Use

    The device must not be used in explosion-hazardous areas, in corrosive environ‐ ments or under extreme environmental conditions. • Any use of accessories not specifically approved by SICK AG is at your own risk. WARNING Danger due to improper use! Any improper use can result in dangerous situations.
  • Page 11: Modifications And Conversions

    Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK software will invalidate any warranty claims against SICK AG. This applies in particular to opening the housing, even as part of mounting and electrical installation.
  • Page 12 The Technical Information RFU65x Regulatory Compliance Information can be found on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 13: Product Description

    Figure 2: RFU650: Layout of the type label of the FCC variant (example) with UL certification, see device for relevant data 2D code (internal SICK code) Marking according to electrical equipment directives Protection class Device identification according to type code...
  • Page 14 It is not possible to connect an external antenna. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 15: Product Characteristics

    “clear” demarcation of the sensing range of the reading field: 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 16 Horizontal plane (azimuth) Vertical plane (elevation) Vertical plane (elevation) O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 17 (*.sdd-file) for the • www.sick.com/SOPAS_ET RFU65x 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 18 NOTE The RFU parameter description can be found on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 19 Optional function blocks for easier integration of the device into PLC programs • PROFINET Single Port: Configuration via GSD parameterization • Application-specific programming possible using the SICK AppStu‐ dio development environment. You can find further information on the Internet at: www.sick.com/ SICK_AppStudio •...
  • Page 20 NOTE The memory card is an optional accessory and is not included with delivery. NOTE Only use types approved by SICK to ensure reliable function of the memory card. NOTE Memory cards can be found on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
  • Page 21 To do this, disconnect the device from the supply voltage beforehand. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 22 ° when there is no power to the device. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 23: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 24: Mounting

    Possible disturbances of the UHF field caused by reflections of the UHF waves are: Overreaches ° “Holes” (destructive interferences) ° O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 25 The screw length required depends on the mounting base (wall thickness of the bracket). When using an optional SICK bracket, screws of appropriate length for mounting the device on this bracket are included in the scope of delivery.
  • Page 26 "Device view", page Optional SICK brackets The device can be mounted using one of the following brackets: optional SICK bracket, a combination of SICK brackets and elements, or a customer-specific bracket. SICK offers prefabricated brackets which are suited for mounting the device in various applications.
  • Page 27 Base clamp, part no. 5327611 Base (e.g. plate, supplied by the customer) NOTE Dimensional drawings for SICK brackets and, if applicable, mounting instructions can be found online at: www.sick.com To do so, enter the 7-digit part number of the bracket in the search field.
  • Page 28: Mounting Location

    O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 29 Recommendation: Depending on the application it may be possible to use one of the optional SICK brackets. If necessary, perhaps also in combination with other brackets At the intended reading point, place an object with transponder within the working range of the device (static object only).
  • Page 30: Mounting External Components

    On the product page you will find connection modules and fieldbus modules as well as accompanying operating instructions for the modules. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
  • Page 31: Electrical Installation

    Figure 11: Example: Occurrence of equipotential bonding currents in the system configuration System controller 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 32 Grounding point 1 Metal housing Shielded electrical cable Optical fiber O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 33 • Select all cables to suit the ambient temperature range at the installation site. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 34 During this time, protect the device against moisture and dust. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 35: Wiring Instructions

    You will find recommended connecting cables and associated technical data on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 36 For a detailed overview, see "Use of the data interfaces", page O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 37 ", page 47 see "Wiring digital outputs ", page 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 38 Input using the terminal in SOPAS ET (from version 3.3.0) or other USB-capable terminal programs. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 39: Pin Assignments Of Electrical Connections

    Digital input 1 RD+ (RS-422) Host Host interface (receiver+) 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 40 TD– (RS-422), Host Host interface (sender–) TxD (RS-232), Host O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 41: Instructions For Electrical Installation When The Ambient Temperature Can Fall Below 0 °C

    Required supply voltage: see "Supply voltage", page 43 • Use SICK standard cables for the specified ambient temperature range. NOTE You will find the technical data for the cables on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
  • Page 42: Connecting The Supply Voltage

    Figure 20: Reversal of the polarity of the supply voltage: no effect on the RFID device (see requirements) O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 43 Supply voltage The voltage source must meet the requirements of ES1 (EN 62368-1). 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 44 When operating the device below 0 °C and using a cold-resistant connecting cable from SICK. When operating the device without a SICK connection module and using a SICK connecting cable. When operating the device below 0 °C, use the cold-resistant supply cable from SICK, part no. 6048319 (2 x 0.25 mm , 10 m).
  • Page 45: Wiring Data Interfaces

    DIN VDE 0298 (Part 4) or DIN VDE 0891 (Part 1) Wiring without SICK connection module Supply voltage 12 V to 30 V DC: when operating the device with the SICK supply cable part no. 6048319 (2 x 2.5 mm , length 10 m) protect the device with a separate 2.5 A slow-blow fuse.
  • Page 46 "Wiring serial host interface RS-422 of the device in CDB650-204", page 89 O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 47: Wiring The Can Interface

    NOTE You will find more connection modules on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 48 Assign the functions for the external digital inputs in the device using a configuration tool, e.g., the SOPAS ET configuration software. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 49: Wiring Digital Outputs

    With inductive load: see note !... " For pin assignment, see respective device 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 50 CDB650-204", page 97 O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 51 If the digital outputs are wired via a connection module, observe the respective operat‐ ing instructions of the module used. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 52: Commissioning

    Connect the communication interface (e.g., Ethernet) of the device directly to the computer using cable 9. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 53 Interfaces Connection modules Configuration and diagnostics Data further processing 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 54 You can find the operating instructions on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 55: Overview Of The Commissioning Steps

    NOTE You can find adapter cables on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 56 Follow the operating instructions to complete the installation. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 57: Quickstart With Default Settings

    Connecting the SOPAS ET configuration software to the device Start the “SOPAS ET” program option after completing the installation. Path: Start > Programs > SICK > SOPAS ET Engineering Tool > SOPAS. By default, the software automatically searches for connected devices via the Ethernet, USB, and RS-232 interfaces.
  • Page 58 Click the Transponder Access button. The Transponder Management Access tab displays the content of the selected transponder. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 59 ° region-dependent, see Technical Information RFU65x Regulatory Compliance Information. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 60: Information On Initial Commissioning

    O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 61 By using a combination of a) plus b) or c) Operating principle 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 62 SOPAS ET configuration software. Memory card NOTE Only use types approved by SICK to ensure reliable function of the memory card. NOTE Memory cards can be found on the product page.
  • Page 63: Operation

    Data traffic via the Ethernet interface PROFINET operation with single port: 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 64 To apply the changed settings, per‐ manently save the changes and restart the device. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 65 For operational use, select a read cycle using the object trigger control in ► SOPAS ET. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 66 NOTE The parameter description can be found on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 67 For more details on using the terminal, see the SOPAS ET manual. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 68 ■ with SICK function blocks for the relevant bus controller. NOTE You will find SICK function blocks for various types of PLC from different manufac‐ turers on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
  • Page 69: Maintenance

    Use a dry cloth or an industrial vacuum cleaner for cleaning. Do not use cleaning agents. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 70: Troubleshooting

    For errors that occur during reading, the device writes errors codes in the status (see "Status log", page 71). O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 71: Status Log

    SICK AG. Fast replacement of a device by the customer is, however, possible. If a fault cannot be rectified, contact the SICK Service department. To find your ► agency, see the final page of this document.
  • Page 72: Replacing The Device

    The first three methods are performed semi-automatically by the device depending on the setup. The fourth method is performed manually. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 73 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 74: Decommissioning

    Separate the recyclable materials by type and place them in recycling containers. ■ O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 75: Technical Data

    Internet. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 76: Interfaces

    You will find the Technical Information RFU65x Regulatory Compliance Information on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 77 Supply voltage. Output current. For example using the SOPAS ET configuration software. This functionality can be unlocked with the SDK6U SD card. Available online at: www.sick.com. NOTE You will find SICK function blocks for various types of PLC from different manufacturers on the product page.
  • Page 78: Mechanics And Electronics

    When connected to the optional SICK CDB650-204 or CDM420-0006 connection module. Using a SICK cable When operated without a connection module using a SICK cable. 2 A fuse protection at the start of the feeding supply circuit. When operated without a connection module using a SICK supply cable part no. 6048319 (2 x 2.5 mm 10 m).
  • Page 79: Working Range Diagram

    12.6 Dimensional drawing RFU650-101xx: Dimensions see "Device view", page 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 80: Accessories

    On the product page you will find accessories and, if applicable, related installation information for your product. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 81: Annex

    Declarations of conformity and certificates You can download declarations of conformity and certificates via the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 82 Female connector, M12, 17-pin, A-coded (front view) Illustration may differ O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 83 Ambient temperature range: For mobile installation: –25 °C to +80 °C, for fixed installation: –40 °C to +80 °C 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 84 Female connector, D-Sub, 9-pin (front view) Figure may differ. O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 85: Connection Diagrams Of Connection Module Cdb650-204

    External trigger sensor, e.g. for read cycle generation Device Interfaces 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 86 Wiring overview of the CDB650-204 Device = RFU650-101xx, 1 digital input used O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 87 (highlighted in gray). Supply voltage V à 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 88 Wiring serial host interface RS-232 of the device in CDB650-204 Device = RFU650-101xx O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 89 S7: Term 485 Figure 40: Wiring data interface RS-422 of the device in connection module CDB650-204. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 90 Wiring the CAN interface of the device in the CDB650-204 Device = RFU650-101xx O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 91 ANNEX Ethernet Ethernet Ethernet (Host port) 1 Serial Host interface 2 SICK CAN SCANNER NETWORK RS-422 RS-232 Host Host CDB650-204 Switch 3 S2 (TermCAN): R‒/RxD TD‒ Connection cable 9 S6 (RS): Controller 4 amongst T‒/TxD RD‒ others (Device 1) 5...
  • Page 92 Connection module: female connector, M12, 17-pin, A-coded E.g. photoelectric sensor PNP sensor Supply voltage V O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 93 ≤ 30 V; 0.7 mA ≤ I ≤ 5 mA Input voltage. Input current. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 94 Switch setting S3 then as in left figure. Trigger sensor, e.g. for read cycle generation O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 95 Wiring digital outputs of the device in the CDB650-204 Device = RFU650-101xx 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 96 • Not electrically isolated from the supply voltage V O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 97 External output A Signal B Terminal C EXT. OUT 1 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 98: Connection Diagrams Of Connection Module Cdm420-0006

    Connection of the device to CDM420-0006 Device = RFU650-101xx O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 99 Wiring overview of the CDM420-0006 Device = RFU650-101xx, 1 digital input used 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 100 External trigger sensor, e.g. for read cycle generation Supply voltage V O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 101 CDM420-0006 and device disconnected from supply voltage Recommended setting for all connection work 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 102 Wiring serial host interface RS-422 of the device in the CDM420-0006 Device = RFU650-101xx O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 103 Wiring the CAN interface of the device in the CDM420-0006 Device = RFU650-101xx 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 104 ANNEX Ethernet Ethernet Ethernet (Host port) 1 Serial Host interface 2 SICK CAN SCANNER NETWORK RS-422 RS-232 Host Host CDM420-0006 Switch 3 S4 (TermCAN): R‒/RxD TD‒ Connection cable S2 (RS485): Controller 4 amongst T‒/TxD RD‒ others (Device 1) 5 CAN 1 7...
  • Page 105 " connected potential-free and supplied with power externally. Now select switch setting S6 as shown in the left figure. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 106 Wiring the external digital inputs of the device in the CDM420-0006 Device = RFU650-101xx O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 107 S ext Input voltage V PNP sensor Supply voltage V 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 108 Wiring digital outputs of the device in the CDM420-0006 Device = RFU650-101xx O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 109 Assign the functions for the digital outputs in the device using a configuration tool, e.g., the configuration software SOPAS ET. 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x...
  • Page 110 Aux Out 2 Functional principle of the external digital outputs O P E R A T I N G I N S T R U C T I O N S | RFU65x 8027758//2022-12-16 | SICK Subject to change without notice...
  • Page 111: Copyright Notices

    Automation GmbH, Germany. Open source programs SICK uses open-source software in the device. This software is licensed by the rights holders using the following licenses among others: the free licenses GNU General Public License (GPL Version2, GPL Version3) and GNU Lesser General Public License (LGPL), the MIT license, zLib license, and the licenses derived from the BSD license.
  • Page 112 Rich Text Format (Standard document format with format descriptions) Radio Frequency Ultra high frequency Secure Digital SOPAS ET SICK Open Portal for Application and Systems Engeneering Tool. SICK soft‐ ware for computer (Windows) for device configuration. SOPAS Device Description (Device description file, driver for SICK SOPAS ET software)
  • Page 113 ANNEX 8027758//2022-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU65x Subject to change without notice...
  • Page 114 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail office@sick.com.gr E-Mail sales.gsg@sick.com Hong Kong Slovakia Phone +852 2153 6300 Phone +421 482 901 201 E-Mail ghk@sick.com.hk E-Mail mail@sick-sk.sk Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

This manual is also suitable for:

Rfu650-101 series

Table of Contents