SPARTUS® full face mask 90
IMPORTANT! Keep these user Instruction for reference.
Before using the SPARTUS® full face mask 90 and the related filters, must carefully read and understand the instruction, and strictly
abide by the relevant content and retention of instruction in use process, please reference. The mask meet the requirement of Re-
gulation (EU) 2016/425 and CE marked accordingly, and have been tested according to EN 136:1998.
Assembly instructions
1
5
9
13
/
/
1
2
3 Assemble or replace gas / particle filter: Align gas/particle filter notch with the bump on facepiece, and push to-
gether. Turn gas/particle filter clockwise to stop. When replacing the gas/particle filter, remove the gas/particle filter by turning it
counterclockwise. 4 Mask fitting: Hold the head harness and cardle away from your face, place your chin where the facepiece fits
against the chin, and press the respirator against your face so that it fits your face. 5 Pull the head harness assembly behind the
head. 6 Tighten the lower straps one by one, paying attention to the same tightness on both sides. 7 Checking the tightness
of the particule filter: Using hands press or squeeze filter covers toward facepiece and inhale gently. If you feel facepiece collapse
slightly and pull closer to your face with no leaks between the face and facepiece, a proper seal has been obtained. 8 Checking
the tightness of the gas filter: Place the palm of hands to cover face of gas filter and inhale gently. If you feel facepiece collapse
slightly and pull closer to your face with no leaks between the face and facepiece, a proper seal has been obtained. 9 After wea-
ring this respirator, press the „Positive Fit Check Button" with your finger to the bottom. 10 Exhale slowly, the facepiece will bulge
slightly. If the respirator can maintain a little positive pressure and there is no obvious leakage between the face and the facepiece,
it means that the seal is good. 11 Respirator removal: Pull the buckle of head harness to fully loosen the 6 head harness straps.
12
Replace the exhalation valve: Open the bottom buckle of exhalation valve cover with your finger and remove it. 13 Remove
The Exhalation Valve from the valve seat by pulling valve stem from valve seat. Replace exhalation valve by inserting stem into hole
and manipulating stem tip until valve seat completely. The valve is flat and free to move. 14 Replace the inhalation valve: Remove
The Inhalation Valve from the valve seat by pulling valve stem from seat. Replace inhalation valve by inserting stem into hole and
manipulating stem tip until valve seat completely. The valve is flat and free to move.
2
6
10
14
3
7
11
EN
USER'S MANUAL
4
8
12
Need help?
Do you have a question about the Full face mask 90 and is the answer not in the manual?
Questions and answers