Pll Clock Multiplier; Overcurrent Detection; I 2 C-Bus Interface; Modes Of Operation - Philips ISP1122A Product Data

Universal serial bus stand-alone hub
Table of Contents

Advertisement

Philips Semiconductors

6.9 PLL clock multiplier

6.10 Overcurrent detection

6.11 I

7. Modes of operation

Table 4:
Mode selection
Mode
INDV
OPTION SP/BP
[1]
0
0
0
1
0
0
2
0
1
3
0
1
4
1
0
5
1
0
6
1
1
7
1
1
[1]
Port power switching: logic 0 = ganged, logic 1 = individual.
[2]
Power mode: logic 0 = bus-powered, logic 1 = self-powered (or hybrid-powered).
[3]
No overcurrent detection.
[4]
No power switching.
9397 750 08958
Product data
A 6 to 48 MHz clock multiplier Phase-Locked Loop (PLL) is integrated on-chip. This
allows for the use of low-cost 6 MHz crystals. The low crystal frequency also
minimizes Electro-Magnetic Interference (EMI). The PLL requires no external
components.
An overcurrent detection circuit for downstream ports has been integrated on-chip. It
is self-reporting, resets automatically, has a low trip time and requires no external
components. Both individual and global overcurrent detection are supported.
2
C-bus interface
2
A basic serial I
C-bus interface (single master, 100 kHz) is provided to read VID, PID
and configuration bits from an external I
equivalent). At reset the ISP1122A reads 6 bytes of data from the external memory.
2
The I
C-bus interface timing complies with the standard mode of operation as
2
described in The I
C-bus and how to use it , order number 9398 393 40011.
The ISP1122A has several modes of operation, each corresponding with a different
pin configuration. Modes are selected by means of pins INDV, OPTION and SP/BP,
as shown in
Table
4.
PSWn/GLn
[2]
(n = 1 to 4)
0
GoodLink
1
GoodLink
0
GoodLink
[4]
1
GoodLink
0
individual power
1
individual power
0
individual power
[4]
1
GoodLink
Rev. 03 — 30 October 2001
2
C-bus EEPROM (e.g. Philips PCF8582 or
PSW5/GL5/GPSW OCn
(n = 1 to 4)
ganged power
inactive
ganged power
inactive
ganged power
inactive
[4]
GoodLink
inactive
inactive
individual
overcurrent
individual power
individual
overcurrent
inactive
inactive
[4]
GoodLink
individual
overcurrent
ISP1122A
USB stand-alone hub
OC5/GOC
global overcurrent
global overcurrent
[3]
[3]
inactive
global overcurrent
inactive
individual
overcurrent
[3]
[3]
inactive
individual
overcurrent
© Koninklijke Philips Electronics N.V. 2001. All rights reserved.
10 of 48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isp1122adIsp1122anbIsp1122abd

Table of Contents