Introduction; General Information; Combinations And Options - Daikin REYQ72TAYC Series Installation Manual

System air conditioner
Table of Contents

Advertisement

1 . Introduction

1 . 1 . General information

This installation manual concerns the VRV IV REYQ-T series, full
inverter driven, heat pump system.
1
2
3
5
4
6
1
Outdoor unit
2
Refrigerant piping
3
Branch Selector unit
4
VRV indoor unit
5
Cool/Heat selector (single Branch Selector unit only)
6
User interface (dedicated depending on indoor unit type)
7
User interface (wireless, dedicated depending on indoor unit type)
INFORMATION
Not all combinations of indoor units are allowed. For guidance, see

1.2. Combinations and options.

1 .2 . Combinations and options
The VRV IV REYQ-T series heat recovery system can be combined
with several types of indoor units and is intended for R410A use only.
For an overview which units are available you can consult the product
catalogue for VRV IV REYQ-T series.
NOTE
To be sure your system setup (outdoor unit + Branch Selector unit(s)
+ indoor unit(s)) will work, you have to consult the latest technical
engineering data for VRV IV REYQ-T series.
An overview is given indicating the allowed combinations of indoor
units and outdoor units. Not all combinations are allowed. They are
subject to rules (combination between outdoor-indoor, single outdoor
unit use, multiple outdoor units use, combinations between indoor
units, etc.) mentioned in the technical engineering data.
The Branch Selector units that combined with REYQ-T units for
changing the refrigerant flow to indoor units are T type
(BSQ-TVJ, BS-Q54TVJ) only. Do not combine the T type and P type
(BSVQ-PVJU, BSV-Q36PVJU) in the system. Combination of T type
and P type cause malfunction.
1 .2 . 1 .
Indoor units combinations
In general VRV indoor units can be connected to REYQ-T units.
1 .2 .2 . Outdoor units combinations
REYQ-T type
REYQ-T units are as indicated in tables below (and right), where
REYQ 192-384 consists of multiple REYQ 72-168 modules as indi-
cated.
3P362438-9N English
3
5
4
6
7
72
1
REYQ72TAYC*
REYQ96TAYC*
REYQ120TAYC*
REYQ144TAYC*
REYQ168TAYC*
REYQ192TAYC*
REYQ216TAYC*
REYQ240TAYC*
REYQ264TAYC*
REYQ288TAYC*
REYQ312TAYC*
REYQ336TAYC*
REYQ360TAYC*
REYQ384TAYC*
To install the outdoor unit, the following optional parts are also required.
1 Refrigerant branch kit.
Description
(for 3 pipes)
KHRP25M33H9
KHRP25M33HA
KHRP25M72H9
REFNET header
KHRP25M72HA
KHRP25M73HU9
KHRP25M73HUA
KHRP25A22T9
KHRP25A22TA
KHRP25A33T9
KHRP25A33TA
REFNET joint
KHRP25M72TU9
KHRP25M72TUA
KHRP25M73TU9
KHRP25M73TUA
For the selection of the optimal branch kit, refer to 7.4. Selection of
refrigerant branch kits on page 11.
2 Outdoor unit multi connection piping kit.
Number of outdoor units connected
2
BHFP26P100U
BHFP26P100UA
3 In order to control the cooling or heating operation from a central
location, the following option can be connected:
- Cool/Heat selector: KRC19-26A
- With optional fixing box for the switch: KJB111A
- Centralized control devices (e.g., intelligent Touch Manager)
4 To instruct specific operation with an external input coming from a
central control the external control adaptor (DTA104A61/62) can
be used. Instructions (group or individual) can be instructed for low
noise operation and power consumption limitation operation.
5 For REYQ-T units it is also possible to make several commissioning
field settings through a personal computer interface. For this option
999482P3 is required which is a dedicated cable to communicate
with the outdoor unit. The software for the user interface program
can be obtained from your local Daikin sales office.
INFORMATION
Refer to the technical engineering data for the latest option names.
96
120
144
168
1
1
1
1
2
1
1
2
1
1
2
1
1
2
3
2
1
Model name
(for 2 pipes)
KHRP26M22H9
KHRP26M22HA
KHRP26M33H9
KHRP26M33HA
KHRP26M72H9
KHRP26M72HA
KHRP26A22T9
KHRP26A22TA
KHRP26A33T9
KHRP26A33TA
KHRP26M72TU9
KHRP26M72TUA
3
BHFP26P151U
BHFP26P151UA
2

Advertisement

Table of Contents
loading

Table of Contents