RTK 725 Series Instruction Manual

RTK 725 Series Instruction Manual

Alarm annunciator
Hide thumbs Also See for 725 Series:

Advertisement

Quick Links

INM725
RTK Series 725 Annunciator
725 Series Alarm Annunciator
Instruction Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 725 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RTK 725 Series

  • Page 1 INM725 RTK Series 725 Annunciator 725 Series Alarm Annunciator Instruction Manual...
  • Page 2 INM725 RTK Series 725 Annunciator The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for safety and MUST be followed CAUTION Cautions are provided to prevent damage to the instrument.
  • Page 3: Table Of Contents

    INM725 RTK Series 725 Annunciator CONTENTS 1. Introduction ......................7     Installation ..................... 8     Unpacking ............................ 8   Basic principles of handling ......................8 2. Front View Examples ..................9     System Front View ........................10 3.
  • Page 4 INM725 RTK Series 725 Annunciator   6.4 Suitable Power Supplies ...................... 29   6.5 P725 Annunciator Standard Versions .................. 29   6.6 P725 Annunciator Fitted With The Repeat Relays Per Channel Option ....... 30 7. Mechanical Details ................... 31  ...
  • Page 5 INM725 RTK Series 725 Annunciator   12.2 Optional Unit With Repeat Relay Facility ................51   12.3 Large Window Versions Fitted With An Odd Number Of Alarms ........52   12.4 Standard Unit Without Repeat Relay Facility ..............52  ...
  • Page 6   31.5 Fuse Replacement ......................98   31.6 Position Of Fuses On The Supply Card ................99 32. Spare Parts Description ................99   33. Other RTK Products ..................102   35. Function Setting per Alarm Sequence ............103  ...
  • Page 7: Introduction

    RTK Series 725 Annunciator 1. Introduction The RTK 725 Series alarm annunciator is used to provide visual and audible warning that a process has gone beyond set limits or to provide status only indication. The annunciator is manufactured from universal cells, each 60 x 60mm, which can be assembled in an array to provide the number of rows and columns required to suit individual panel designs.
  • Page 8: Installation

    If any damage has occurred please report the damage to the freight forwarder and copy RTK. The alarm annunciator is supplied with panel mounting clamps locked in place, however please check all packages to ensure that no additional pieces are left in the box as any auxillary items like power supplies, horns, pushbuttons or spares kits will be packed separately.
  • Page 9: Front View Examples

    INM725 RTK Series 725 Annunciator 2. Front View Examples Systems supplied prior to June 2013 1 X CELL SMALL LAMP NO 1 FULLY PROTECTION WINDOW AIR COOLER FIELD TRIP COLOURS VERSION FAILURE PROGR AVAILABLE 30 X 30 MM VERSIONS OPTIONAL...
  • Page 10: System Front View

    PRINTED FILM LEGENDS Medium Window Version Large Window Version System Front View Systems supplied after June 2013 On systems supplied after June 2103 RTK revised the framing of the annunciator as typically shown below SMALL LAMP NO 1 FULLY PROTECTION...
  • Page 11: System Description & Features

    INM725 RTK Series 725 Annunciator MEDIUM WINDOW VERSION LAMP TEST Typical Medium Window Version 3. System Description & Features 3.1 General Annunciators are manufactured to meet individual customer's requirements using separate "cells" which can be assembled in configurations from 1 to 16 cells high and 1 to 16 cells wide as required.
  • Page 12: Window Colours

    INM725 RTK Series 725 Annunciator 3.2 Window Colours Systems supplied before June 2013 Each channel is equipped with its own removable bezel, which contains a clear lens, white diffuser, coloured filter and a laser printed film legend. Part Small Window...
  • Page 13 RTK Series 725 Annunciator Systems supplied after June 2013 In June 2013 RTK simplified the Bezel assembly and removed the need for a diffuser. Each channel is equipped with its own removable bezel, which contains a clear lens, coloured filter and a laser printed film legend.
  • Page 14: Laser Printed Legends

    Laser printed film legends are easily generated, from within Microsoft Excel, in a font style and size to suit individual applications. A software template is available, free of charge from RTK, which allows the user to produce film legends locally if required. Completed film legends are located between the clear front lens of the removable window assembly and the associated coloured filter and diffuser.
  • Page 15: Lamp Or Led Illumination

    All units are suitable for either 28V - 10 mm wedge based lamps part no. LP-28-004 LED Assemblies RTK use LED assemblies as standard, which plug into the standard lamp socket, as they offer lower power consumption and offer a maintenance free solution.
  • Page 16: Alarm Card Types

    RTK Series 725 Annunciator 3.6 Window Numbering System RTK have adopted the following window numbering system to aid with the location of the film legend and the associated alarm cards. This method is used to ensure that the legend matches the functions selected for the designated alarm.
  • Page 17: Pushbutton / Programming Module Options

    INM725 RTK Series 725 Annunciator 3.9 Pushbutton / Programming Module Options The pushbutton/programming module is normally integrally mounted within the annunciator however if required it can be supplied as a standalone item suitable for panel mounting, DIN-rail mounting or wall mounting.
  • Page 18: Automatic Mute Or Automatic Acknowledge

    INM725 RTK Series 725 Annunciator Sleep Mode Jumper Location MULT SUPPLY 24VDC OV OVC +V +VC T Side View Assy Pt No CB4642POP1 Sleep Mode Switch WARNING! Remove ALL power from the unit and fully remove the card before changing any jumpers or switches 3.13 Automatic Mute Or Automatic Acknowledge...
  • Page 19: Integral Audible Alarm

    INM725 RTK Series 725 Annunciator Auto Mute / Ack Delay Switch Location (Information Plate Removed) CB4072POP Posidrive screws A4219-* Automatic Acknowledge or Silence Time Selection FUNCTION SW7-1 SW7-2 SW7-3 SW7-4 Automatic acknowledge Automatic mute Disable automatic timer Enable 1 minute time delay...
  • Page 20: Horn Adjustment On Remote Pushbutton / Programming Modules

    INM725 RTK Series 725 Annunciator Integral Horn Volume Adjustment Location Increase Internal audible volume adjustment FUNCTION STATUS CONF 3.14a Horn adjustment on Remote Pushbutton / Programming Modules On P725 Systems supplied with Remote Pushbutton / Programme Modules the horn adjustment potentiometer is located in an alternative position to that shown above.

Table of Contents