1455 Kleppe Lane Sparks, NV 89431-6467 (888) 909-4297
Bottle Filler with Lifecycle Control
NOTE: A Class A ground-fault circuit interrupter
(GFCI) shall be installed in the branch-circuit
supplying power to this unit.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL, OR REQUIRE REPLACEMENT PARTS, PLEASE CALL:
HOURS OF OPERATION: MON-THURS 7:00a.m. - 4:30p.m PT, FRI 7:00a.m.- 11:00a.m. PT
PARTS LIST: 1 bottle filler, 1 filter cartridge, 1 plastic drain basin, 1 brass waste bend, 1 waste
nut, 1 rubber waste washer, 1 hex key, 2 drain basin screws, 2 drain basin screw washers.
RECOMMENDED TOOLS: Phillips screwdrivers, level, slip joint pliers.
REQUIRED PARTS (NOT SUPPLIED): Qty. 6 – 10 #6 sheet metal or wood screws (depending on
construction of wall studs), 1/2" screwdriver stop, 3/8" tubing (to be used for water supply inlet), 1-
1/4" trap, qty. 3 wire connectors.
PRODUCT INSTALLATION: When installing this product, local, state or federal codes should be
adhered to. This unit is certified for indoor use only.
SUPPLY LINE: Minimum recommended line size is 1/2" IPS with 30-90 PSI (2-6 ATM) flowing
pressure; supply water is to be cold water supply. Intended for municipal water only.
PLUMBING CONNECTIONS: Inlet is 3/8" O.D. push-in type fitting. Waste bend is 1-1/4" O.D.
pipe; an acceptable trap must be used after waste bend.
ELECTRICAL CONNECTIONS: 115VAC, 60HZ, approx. 0.14A. Unit wired directly to incoming
line (stripped leads provided).
RATED SERVICE FLOW: 0.5 GPM (2725L/day)
OPERATING TEMPERATURE: 35–100
OPERATING PRESSURE: 30-90 PSI
FILTER CAPACITY: 2500 gallons (9460L) or 1 year
REPLACEMENT FILTER CARTRIDGE: Electronic Lifecycle Control Filter Model 6423
®
© 2017 Haws
Corporation – All Rights Reserved
®
HAWS
and other trademarks used in these materials are the exclusive property of Haws Corporation.
08/17
website:
www.Hawsco.com
Model 2000S/2000SN
TECHNICAL SUPPORT:
1-800-766-5612
QUICK START REFERENCE
°
F (1.7–37.8
Model 2000S/2000SN
INSTALLATION GUIDE
CAUTION! Prior to making any electrical
connections, verify with a voltmeter that power
from the service panel is off.
°
C)
No. 0510000663 (2)
Page 1 of 6