Technibel GRF148MR5IAA Technical & Service Manual page 14

Dc inverter multi-system air conditioner
Table of Contents

Advertisement

Outdoor Unit
GRF318MR5I
Control PCB
Part No.
Controls
Control Circuit Fuse
Compressor
Type
Compressor Model / Nominal Output
Compressor Oil ... Amount
Coil Resistance (Ambient Temp. 20 °C)
Safety Device
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Overload Relay
Run Capacitor
Crankcase Heater
Fan
Type
Q'ty ... Dia.
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool:Hi / Heat:Hi)
Nominal Output
Coil Resistance
(Ambient Temp. 20 °C)
Safety Device
Type
Over-Current Protection
Over-Heat Protection
Run Capacitor
Heat Exchanger Coil
Coil
Rows
Fin Pitch
Face Area
External Finish
cc
Ohm
Model
Operation Temp.
Micro F
VAC
mm
W
Ohm
Micro F
VAC
mm
m
2
14
CB-CMRV3144EH
Microprocessor
250V 25A
DC Twin Rotary (Hermetic)
5JD420XAB22 / 3,000W
FV50S ... 1,200
U - V :
0.435
V - W :
0.441
W - U :
0.452
Yes
Yes
Yes
CS-7LN115
Open : 115 °C, Close : 100 °C
-
-
230V 25W
Propeller
1 ... D460
DC Motor
SIC-71FW-D490-1 ... 1
8
750 / 750
90
-
Internal Controller
Yes
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.4
0.723
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.