Advertisement

Air filter replacement procedures
When replacing the lamp unit, also replace the air filter.
After turning the power off following the Operating Instructions of the projector,
remove the power plug.
Remove the air filter.
The projector has two same
air filters, one at the right
and the other at the left.
Pull the air filter tab toward
you, and remove it from the
main unit.
Set the air filter.
Install the air filter in the reverse order to step
Install the air filter into place with the filter material facing the back.
• The air filter must be installed in place when using the projector.
Attention
Using the projector without the air filter installed inside, dirt and dust are sucked into the projector,
causing failure.
• Clean the air filter section once every 100 hours or so as a guideline depending on the location of
projector operation.
• Do not rinse off the air filter with water. Doing so will impair the filter's ability to provide protection
from dust.