Advertisement

Quick Links

DB01 Operation Guide
ShenZhen Eelink Communication Technology Co., Ltd.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the DB01 and is the answer not in the manual?

Questions and answers

Summary of Contents for e2Link DB01

  • Page 1 DB01 Operation Guide ShenZhen Eelink Communication Technology Co., Ltd.
  • Page 2 Ⅰ: DB01 parameters • • Data communication: Connect to a computer via APP or Model: DB01 USB to obtain historical data of the recorder. APP • synchronization can be uploaded to the cloud. Communication method: BLE 5.0 • • Data format: PDF/CSV file Recording capacity: 4MB.
  • Page 3 Ⅱ: Menu Functions The menu interface has 4 pages: main menu, maximum/minimum menu, alarm upper and lower limit menu, historical data curve; • Main menu: The main menu displays the current working status of the device which includes alarm information, current temperature, current humidity, average temperature, average humidity, number of records, and battery power.
  • Page 4 • Maximum/Minimum Menu: Maximum and minimum temperature/humidity. MAX: The maximum value of temperature and humidity from the start record to the current time MIN: The minimum value of temperature and humidity from the start record to the current time No Maximum and minimum value when device is Not Started Status Started Status not started.
  • Page 5 • Historical Data Curve 1)The screen can only display the temperature history curve of the latest 120pcs data. 2)The upper left corner shows the upper limits of the temperature. The lower left corner shows the lower limits of the temperature. 3)The upper right corner is the date.The lower right corner is the time.
  • Page 6 Ⅲ: Hardware function Indicator When device start, long press the left button, the indicator light flashes once to indicate successful mark. Screen Status: 1.After being lighted for 5 seconds by default, the screen goes 2.The screen is always on: to sleep again. •...
  • Page 7: Key Function

    Key Function: Not started Started Long press Short Press Short Press Long press 3seconds 3seconds Left Key Menu page flip Start to record Menu page flip Mark data Right Key Back to main menu View device QR code Back to main menu Stop record Left key + right key: turn on/off Bluetooth broadcast On: Bluetooth icon in the Screen status bar.
  • Page 8 Ⅳ:USB tool introduction Connect the device with the computer via USB. Use the E2L USB HID reading tool to obtain the cached data in the device. The tool language changes with the computer system language. First, Run E2L USB HID setup.exe,Install the reading tool. After the software is installed, an icon will be generated on the desktop.
  • Page 9 • Export data Open the E2L USB HID data management system and plug the device directly into the USB port of the computer. Click "Connect Device". Select the query period or directly click Query All to import the historical data The queried data can be viewed in the form of a table/curve to view the historical data of temperature and humidity.
  • Page 10 • Device Parameters Click the device parameters to know the configuration of the device. Current time: the device time when the device parameter is clicked. Temperature and humidity information: The device's temperature and humidity alarm conditions, Exceed the upper limit or lower limit to trigger the alarm.
  • Page 11 Ⅵ:How to use APP Download Keelin-Beacon App through the following QR code or search and download through APPStore • Turn on the phone's Bluetooth and run the Keelin- Beacon APP. • The APP automatically scans the surrounding Bluetooth devices. (Pay attention to turn on the mobile phone Bluetooth and GPS) •...
  • Page 12 • Get device historical data Enter the correct password within 30 seconds and click OK to proceed to the next step. Password is keelin by default. 1) After the connection is successful, click Sync Data. 2) Select the period for which historical data needs to be obtained.
  • Page 13 Export data: Select the file format, you can export it to the file management in PDF/XLS format, which is convenient for exporting and viewing. The Android version files are stored in: phone management/BleExcel/device MAC address folder. IOS version, sent by way of sharing. ShenZhen Eelink Communication Technology Co., Ltd.
  • Page 14 • Modify device parameters 1) Alarms setting: Temperature alarm, Humidity alarm, Light sensor alarm, Tilt alarm, Vibration alarm. 2) Basic parameters: Broadcast interval, Collection interval, Storage interval, Broadcast power, Time zone. 3) Password device: Remove password, Change password; 4) OTA Air upgrade 5) General settings: Edit the device name, Keep status of “screen on”, synchronize the time, restart the device,...
  • Page 15 • Alarms Settings Light alarm Vibration alarm Tilt alarm Levels of Light sensor Vibration level: sensitive, Tilt level: sensitive, ordinary sensitivity: high,medium,low. ordinary, moderate, severe. High sensitivity: Sensitive level Slight vibration. Sensitive level Slight tilt. little light will trigger device to Severe level Large vibration generate an alarm;...
  • Page 16 • Basic Parameters setting 1) Broadcast interval The shorter the broadcast interval, the easier to scan the device, the greater is power consumption. 2) Collection interval The shorter the collection interval, the more frequently the broadcast data is updated, the greater power consumption.
  • Page 17 • Password setting Device password is keelin by default. The length of password is no more than 8 digits which include both numbers and letters. ShenZhen Eelink Communication Technology Co., Ltd.
  • Page 18: General Settings

    • General settings 1) Edit device name The length of Name cannot exceed 16 bytes. A Chinese character occupy 6 bytes. A letter and number occupy 2 bytes. After modifying the device name, the device needs to be restarted to take effect. 2) The screen is always on Turn on the screen on switch, the screen is always on.
  • Page 19 • Channel settings Eddystone defines many Frame Types, that allows Beacon to send many different types of information. The current three types are defined as follows: The iBeacon data packet contains UUID, Major and Minor three information, the parameter settings are as follows: ShenZhen Eelink Communication Technology Co., Ltd.
  • Page 20 THE END ShenZhen Eelink Communication Technology Co., Ltd.