INSTALLATION INSTRUCTIONS
Johnson Suisse Emilia FTW Suite
Code JTTE401.JTTE402
DESCRIPTION
The Emilia suite is a fully concealed, low-projection, comfort height, rimless,
flush to wall suite that has a variable set out option.
The suite is supplied with an adjustable S Trap connector fitting that permits a 90-
140mm set out range. For longer set out (140-170mm) alternative connector
(Code X011B) is needed. see Diagram 1.
The suite may also be connected in a P Trap configuration (fittings not supplied).
Water inlet is back entry - an optional bottom-entry conversion kit (XJ108) is
available.
The cistern is bolted to the pan from inside the cistern tank and can be removed if
necessary for servicing.
The suite has a soft close seat JSEE101 that is attached via top-fixed bolts. The
seat is removable for cleaning. Other seat options are also available for this suite.
Floor fixing brackets are provided.
DIAGRAM 1
145
620
365
INSTALLATION STEPS
1. I nspect pan, cistern and seat for any transit or damage or other defects before starting installation.
2. C heck site roughing in, cistern tap position and assembly dimensions before starting installation. The Pan must be
installed on a level surface.
3. Place the pan in position ensuring it is aligned with the centreline of the sewer connection. Mark the location of the
pan fixing bolt holes.
4. Remove pan and locate the position of the floor brackets 25mm in from the external edges of the pan side. Drill the
holes (10mm) in the floor to attach the floor fixing brackets. (
5. For S Trap installation adjust the threaded bracing prop on the pan connector elbow to the correct length to suit the
set out. Cut the pan connector fitting to the correct length (173mm from wall) and height (190mm from floor) to suit
the job. Install the connector and secure the bracing prop to the back wall. Ensure that the outlet connection
engages correctly with the pan when fully back against the wall.(
250
HEIGHT FOR
BACK-ENTRY
420
WATER INLET
775
DIAGRAM 2
Drill 10mm
fixing holes
in floor
Pan fixing bolt
25mm gap from
outline to bracket
OUTLINE OF
FOOT OF PAN
365
380
125
840
440
190
)
DIAGRAM 2
DIAGRAM 3
DIAGRAM 3
1/4
140
380
175
460
)
175
90-140
OR
140-200
WITH OPTIONAL
X011B CONNECTOR
L/R side access
hole for bottom
water inlet

Advertisement

loading

Summary of Contents for JohnsonSuisse Emilia FTW Suite JTTE401

  • Page 1 INSTALLATION INSTRUCTIONS Johnson Suisse Emilia FTW Suite Code JTTE401.JTTE402 DESCRIPTION The Emilia suite is a fully concealed, low-projection, comfort height, rimless, flush to wall suite that has a variable set out option. The suite is supplied with an adjustable S Trap connector fitting that permits a 90- 140mm set out range.
  • Page 2 13. Fit seat (refer to specific instructions included with seat) WARRANTY - Please visit www.johnsonsuisse.com.au for warranty terms and conditions All installations should be carried out by a licensed plumber in compliance with the requirements of AS/NZS 3500.1 & AS/NZS 3500.2 and any State or Local Authority Regulations.
  • Page 3 VALVE SERVICE INLET VALVE SERVICE IMPORTANT CRITICAL Please read and follow these step-by step instructions to ensure correct installation LEVEL When the outlet valve is installed there must be a • Min 65 Max 145 minimum gap of 25mm between the top of the overflow tube and the Critical Level (CL) mark on the inlet valve.
  • Page 4 Bathroom Products Australia Pty Ltd (ABN: 87 079 297 617) 2/97 Banksia St. Botany, NSW, 2019 Australia WARRANTY: T : 1300 717 717 For warranty terms and conditions, F : 1300 746 480 please refer to: E : bpa.info@johnsonsuisse.com.au www.johnsonsuisse.com.au R0.2...

This manual is also suitable for:

Emilia ftw suite jtte402