Hitachi RAC-VJ18PHAE Service Manual page 40

Hide thumbs Also See for RAC-VJ18PHAE:
Table of Contents

Advertisement

DISCHARGE, PROCEDURE AND POWER SHUT OFF METHOD FOR
POWER CIRCUIT
Caution
Voltage of about 320 V is charged between the terminal of smoothing capacitors.
During continuity check for each circuit part of the outdoor unit, be sure to discharge the smoothing
capacitors.
Discharge Procedure
1. Turn off the power.
2. After power is turned off, wait for 10 minutes or more. Then, remove electrical parts cover
and apply soldering iron of 30 to 75 W for 15 seconds or more to IPM (24) and IPM (20)
terminals on the main P.W.B. as shown in the figure below, in order to discharge voltage
in smoothing capacitor.
LEAD WIRE
LEAD WIRE
WARNING
RAC-VJ18/25/35PHAE
SOLDERING IRON (30 TO 75W)
RAC-VJ42/50PHAE
SOLDERING IRON (30 TO 75W)
- 40 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-vj25phaeRac-vj35phaeRac-vj42phaeRac-vj50phae

Table of Contents