Fiber PoE DC Resistance Test Delete A Project Multi-Gig, PoE and BASE-T Test LiveWiremap a. Creating Project/Profile Cable Set Reference Adjusting Test Limits Cable Test Limit Selecting Cable/Connector Cables & Connectors Validation Test Options WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Page 3
VLAN Discovery Switch Detail TCP Connect Wi-Fi Wireles Network Test DB Manager iii. Signal Strength Network Autotest Selecting Test Limit Selecting Cable/Connector iii. Performing Network Autotest Saving Network Autotest TestDataPro Cloud WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Starts an Autotest (Type of Autotest depends on the adapter attached to the unit. • LCD DISPLAY Capacitive/Resistive touchscreen, with color graphical user interface to navigate the menu and to view results. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Page 5
Connection for 5V DC supply (WARNING : Do not connect to any power supply other than the power adapter supplied by AEM). • TEST ADAPTER A variety of plug and play adapters can be used to change the function of the TestPro CV100 modular platform. • STAND Retract stand to place it on a table or any other flat surface, freeing you to perform other tasks while keeping an eye on the screen.
Select the timer & choose the preferred time duration of inactivity after which the screen should turn off. • Select Edit Time • Scroll up/down to choose the HH, MM and AM/PM. Select [Save]. The drop down menu to select the timezone. • WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
To adjust the volume, select Audio • Select [Units.] Volume & choose Mute, Low, Medium or High. • Select the preferred measurement standard - Metric e. Language (Meter) or US units (Feet). WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Users with K05 and K30 kits who purchased the fiber kits will not require a license to perform fiber certification test as the If [Yes], TestPro will automatically start the Autotest when the license is included with the purchase of the fiber adapter. cable under test is connected to the device port. When [Only for Bidirectional Test After Fiber Swapping] is enabled, the Autotest will continue after successfully swapping the fiber cable during a dual-ended bi-directional test. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
TestPro and insert the USB flash drive > Select [Copy License]. • A [License successfully updated] window will confirm that the license has been updated. Select close to exit • Click [Settings] on the home screen, then [Device]. the window. • Click [Unit Type]. • Check the license info in [License Details]. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Click [Storage]. • Wait for Resetting Battery Gauge to be completed. o. Battery Info Note : Ensure that the battery is fully charged to 100%. AEM recommends to charge the battery overnight. Select [Reset Battery Gauge]. III. TestPro will apply the changes and reset the battery registers.
On the USB flash drive, create a folder “CustomLabel” Import Label List, Copy License , Upgrade Firmware, Export (Without the ““) and copy all the labels that are to be Project and Import imported. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
TestPro’s firmware can be upgraded using the USB flash drive. The firmware version should be 2.4 or later to support USB zip upgrade. • Go to www.aem-test.com/myaccount, log in to your account (create account for new users) and download the latest firmware under [Downloads]. • Save the OSUpgrade.zip to a USB Flash drive (formatted as FAT32).
Select to reboot the device. • Key in the project name and select [ ]. 2 Cable Certification Test • A dialog box will appear confirming the TEST PROJECT The TestPro CV100 platform features the most sophisticated RF to be used as a current project. Select [Yes] and TestPro measurement engine available in any handheld tester. Capable will show various profiles. Select a profile and Save. of supporting up to 3Ghz frequency range, and testing all mode [Certification] for Copper Cable Certification.
& labels through project cloning. • To clone a project open [Project/Profile] in the main menu and choose [Project Manager]. Select the project to be cloned i.e., Building A and select Clone. • Key in the cloned project name & select [ ]. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Set reference has already been performed before shipping the product, therefore it is not necessary to perform it again when the product is received. • Select [Project] on the home screen to choose an active test project. • Select [Edit test profile] to update the test profile. • Select [Limit] to change the test limit. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
If unsure of the type of cable, select [Generic UTP] for unshielded cable &[Generic Shielded] for shielded cable. • Choose the specific type of cable i.e.. CAT6A FTP and select [Save]. Some users may prefer to use customized limits to fit their testing needs. TestPro provides a way to import these limits using TestDataPro PC Software. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Key in the desired label name as well as the descriptions There are cases that the cable being used to test is not yet for [Start] and [End]. available in AEM TestPro cable database. In this case, users • Select [Add] to finish creating the label. can add a cable in the database to be used for testing &...
A list of labels will show up. Choose the label and this screen. select [Save]. A dialog box will confirm that the results • Autotest commences. are being saved. Note: To test only patch cords, you must use appropriate PATCH CORD adapters WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
• Open [Cable Certification] and select [Tools]. • Select [Tone Generator]. • Select [Tone 1]. Closing the Tone Generator screen will It is desirable to attach both ends of the cable to a main turn off Tone 1. and remote TestPro units to get the full test result. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Example above: the total cable length is 34.7 meters of which TestPro detected shield discontinuity at 2.0 meters away from the main unit and 30.8 meters away from the TestPro remote unit. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
TestPro CV100 User Manual p. AD-NET-CABLE Certification Test q. MPTL Certification Test AEM’s AD-NET-CABLE adapter is a multi-purpose adapter that can be used for Multi-Gig SNR measurements, PoE reading, Network Test Tools and CAT6A Cable Certification. Patch Panel Data Outlet Patchcord This adapter has two modes, Validation and Certification Horizontal Cabling mode. To use this adapter for CAT6A cable certification, the adapter has to be switched to certification mode.
Note: The mandrel diameters are based on nominal values of 20 mm (0.79in) and 25mm (0.98in) reduced by the cordage diameter and rounded up. Mandrel prescriptions apply to 850nm and 1300 nm sources. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
2 meter reference cords to remote. Three Jumper Set Reference – connect 2 meter reference cords from main to fiber connector, then 2 meter reference cords to another fiber connector and another 2 meter reference cords to remote. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
TestPro main unit’s Rx port Note: Wait for 5 minutes for the fiber components to forming a loopback connection. warm up before performing the set reference. Doing this will help to produce more stable & consistent results. • On the TestPro main screen select [Fiber Certification]. • Select [Tools]. • Select [Set Reference]. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
• default values will be populated in the [Certification Limit] screen, allowing users to modify the values. When [Loss Budget] is selected, users will be required to • enter the loss budget in decibels (dB). Default value is 10 dB for Multimode and 3 dB for Single-mode. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
• Select [Cable]. • Select from the list of fiber cable manufacturers or [Generic SMF]. • Once the Autotest is complete, TestPro will display a • Select the required cable type and select [Save]. summary. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
TestPro has built-in USB Video Class (UVC) drivers to support any fiber. • On the main menu, select [Fiber Certification]. Select [Tools]. Select [Fiber Inspection]. • TestPro will automatically detect the fiber inspection probe and display the view of the fiber cable in TestPro screen. In this example, the dirt can be seen in the fiber inspection probe. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Multi-Mode (if required) 2 meters • Attach the single mode or multi mode fiber adapter to the TestPro main and remote units. Mandrel Wrap for Multi-Mode (if required) 1. Attach fiber cables to test both ends of the reference cables. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Connect a separate set of two 2-meter • Replacing DC reference cord. reference cords to a TestPro remote unit’s Tx and Rx ports and the other AEM recommendations for Fiber DC set reference: ends to a separate set of fiber adapter of connectors. • Use the DC resistance cable that came with the fiber Connect two cables under test to the fiber adapters/connectors.
Gig & PoE as current project? Choose a profile from the list and click Save. Valid • profiles for TestPro are listed below: [Validation] for Multi-Gig tests [Certification] for Copper Cable Certification [Single Pair Ethernet] for Copper Cable Certification with less than 4 pairs [MM Fiber] to Multimode Fiber [SM Fiber] for Singlemode Fiber [Network Validation] for Network Autotest [Coax] for Coax Certification [Copper 2 Pairs] for Copper Cable Certification using 2 pairs WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
& [Generic Shielded] for shielded • Connect the second end of the cable to a network cable. device i.e., network switch/router. • Choose the specific type of cable. Follow a similar process for choosing connectors: WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
(PSE). It tests measurements for link speed, SNR, and PoE. Internal and external load tests check if the link can support 2.5Gbps/5Gbps/10Gbps when voltage is injected to it continuously. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
External load tests help to qualify link speeds of 2.5Gbps/5Gbps/10Gbps when there is a loaded PoE. Qualified PoE loads i.e., POE load boxes supplied by AEM that draw constant power can be connected to the banana sockets to monitor the Signal SNR in the presence •...
• Choose a limit in the list and the limit will be saved in the test profile. Please contact AEM support @ customercare@aem- test.com for assistance in creating a custom limit. c. SPE Cable & Connector To choose a cable and connector for Single Pair Ethernet (SPE), make sure that the correct SPE cable and connector is selected for proper documentation and reporting.
Set Reference using a crossover cable and wiring option is no longer necessary when a 4-Pair straight cable (T568A and T568B) is already completed before shipping the product. AEM recommendation is to perform set • Select [COAX]. reference using T568A or T568B wiring option when the •...
It comes with network tools to aid troubleshooting and validation efforts. Note: Connect an Ethernet cable from the TestPro side port to a live network. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
(remote node) in the route path or the sum of the mean times in each hop is a measure of the total time spent to establish the connection. • To start Traffic Generator select [Tools]. • Select [Traffic Generator] WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
VLANs allow a network administrator to group hosts that are connected to the same network switch to different local area networks. They also facilitate a number of advantages & functions such as ease of administration, confinement of broadcast domains, reduced broadcast traffic, & enforcement of security policies. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
(default is set to 30 seconds). Increase the timeout when the tester fails to detect the switch information. Select the protocol to be used - [CDP], [LLDP] or both. Select [Start Test]. • Switch Detail commences. Once the Switch Detail process is complete, the results • will be displayed. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Wi-Fi and to cancel. • TestPro will display more details about the test such as TestPro is now connected to AEM-TEST access point • Domain Name, Port and its status, IPv4 Address and with corresponding signal strength in dBm displayed.
-90 dBm is the weakest & 10 dBm is the strongest wireless signal. This is a great tool to check weak signals and blind spots after access point installation. It has WI-FI hand-off functionality to force hand-offs from one access point to another that shares the same SSID & password. To get Signal Strength: WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Note: In Full Discovery mode, TestPro will scan the entire network. After network discovery scanning, Autotest will continue with other tests. In [Time Bound] mode, TestPro will scan the network for the specified duration. ii. Selecting Cable/Connector Refer to 2e i .select cable/connector section WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Test data stored in the internal storage of the TestPro unit can be retrieved by connecting a USB flash drive to it. The data can also be retrieved through a USB cable connection between the TestPro and a PC running the TestDataPro software. Results can also be retrieved through TestDataPro Cloud. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
TestDataPro. Install the TestDataPro software and refer to the TestDataPro user guide. The procedures for importing data into TestDataPro and generating test reports are also illustrated in the following pages: WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
USB port on the tester prior to packing it up. Failure to do so could result in adapter damage during transport. In addition, the Edimax adapter will always draw power from the tester when it is plugged in. WWW.AEM - TEST.COM customercare@aem-test.com | Version # : 2.2...
Page 47